Du Pont Apollo DA105-A2 is a 105.0 W STC (95.5 W PTC) Thin Film solar module ranking #21,543 of 21,677 CEC listings (below all-CEC median; higher than 0.6% of peers). It delivers 6.82% efficiency, 100.0 V Voc at 25 C, and 111.48 V cold Voc at -10 C (5 panels max per 600 V string).
- STC Wattage
- 105.0 W
- PTC Wattage
- 95.5 W
- Voc @ 25C
- 100.0 V
- Efficiency
- 6.82%
How Does Du Pont Apollo DA105-A2 Compare Against Peer CEC Listings?
Solar engineering breakdown for Du Pont Apollo DA105-A2: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 105.0 W STC and 95.5 W PTC, Du Pont Apollo DA105-A2 sits -280.0 W vs all-CEC median (below all-CEC median; higher than 0.6% of peers) among 21,677 listed modules. Power density reaches 68.2 W/m2 (13.09 percentage points below 19.91% CEC median). Higher 100.0 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 8 panels in series. Alternative peer Applied Materials 1/4 Size Single Junction Version 10 rates 116.0 W.
Where Does Du Pont Apollo DA105-A2 Fall Across Listed CEC Models?
Distribution marker showing Du Pont Apollo DA105-A2 (105.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Du Pont Apollo DA105-A2?
Dataset percentiles tracking Du Pont Apollo DA105-A2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Du Pont Apollo DA105-A2?
Benchmark highlights for Du Pont Apollo DA105-A2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
105.0 W STC · Higher Than 0.6%
105.0 W STC (-280.0 W vs all-CEC median) vs 117.5 W Thin Film median.
6.82% Aperture Efficiency
Power density 68.2 W/m2 (13.09 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).
5 Panels Max @ -10 C (600 V)
Cold Voc reaches 111.48 V at -10 C (557.4 V string) and 114.76 V at -20 C (5 max).
77 Panels = 8,085 W STC
Occupies 118.6 m2 (1,276 sq ft) producing 7,354 W PTC; NEC 690.8 OCPD floor is 2.59 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 100.0 * (1 + (-0.328/100) * (-10 - 25)) = 111.48 V | OCPD = 1.56 * 1.66 = 2.59 A
Inputs from CEC Modules.csv for Du Pont Apollo DA105-A2: Voc=100.0 V, beta_Voc=-0.328%/C, Isc=1.66 A, STC=105.0 W, Area=1.54 m2.
Result: 5 panels max on 600 V (557.4 V); 77 panels for 8 kW (1,276 sq ft).
What Are the Published CEC Specifications for Du Pont Apollo DA105-A2?
Official CEC datasheet figures for Du Pont Apollo DA105-A2 (Thin Film) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 105.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 95.5 W (91.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 100.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 75.0 V / 1.4 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.328 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 6.82% (1.54 m2) | Array roof footprint density |
| Cell Count & Technology | 119 cells (Thin Film) | Monofacial backsheet |
How Many Du Pont Apollo DA105-A2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Du Pont Apollo DA105-A2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 58 | 6.09 kW | 961 sq ft | $1,524 | $2,577 |
| 8 kW Class | 77 | 8.09 kW | 1,276 sq ft | $2,025 | $3,424 |
| 10 kW Class | 96 | 10.08 kW | 1,591 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Du Pont Apollo Series?
Consolidated Du Pont Apollo wattage variants sharing the Du Pont Apollo DA105-A2 mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Du Pont Apollo DA100-A2 | 100.0 W | 90.9 W | 100.0 V | 75.0 V | 6.49% |
| Du Pont Apollo DA105-A2 | 105.0 W | 95.5 W | 100.0 V | 75.0 V | 6.82% |
How Many Du Pont Apollo DA105-A2 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Du Pont Apollo DA105-A2 (111.48 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 114.76 V | 5 panels | 573.8 V | 8 panels |
| -10 C (14 F) | 111.48 V | 5 panels | 557.4 V | 8 panels |
| 0 C (32 F) | 108.2 V | 5 panels | 541.0 V | 9 panels |
| 25 C (77 F STC) | 100.0 V | 6 panels | 600.0 V | 10 panels |
Which Cross-Brand Solar Modules Compare Closest to Du Pont Apollo DA105-A2?
Competing CEC solar panels closest to Du Pont Apollo DA105-A2 in nameplate wattage and Voc, starting with Applied Materials 1/4 Size Single Junction Version 10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials 1/4 Size Single Junction Version 10 Applied Materials |
116.0 W | +11.0 W | 96.2 V | 8.11% | 93.0% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | -2.5 W | 93.0 V | 7.19% | 93.0% |
| T-Solar Global TS97 T-Solar Global |
97.5 W | -7.5 W | 93.0 V | 6.84% | 92.9% |
| First Solar Inc FS-4105 First Solar Inc |
105.0 W | Tie (0 W) | 88.2 V | 14.58% | 94.6% |
What Are the Design Limits and Best-Fit Uses for Du Pont Apollo DA105-A2?
Evaluate Du Pont Apollo DA105-A2 (105.0 W STC, 100.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Du Pont Apollo DA105-A2 reaches 114.76 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 77 panels for an 8 kW build require 1,276 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 77 panels (1,276 sq ft).
- 2026 tax credit baseline: cash residential installs of Du Pont Apollo DA105-A2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Du Pont Apollo DA105-A2 8 kW Residential Fit
Needs 77 modules (1,276 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare Applied Materials 1/4 Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 95.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Du Pont Apollo DA105-A2 by Du Pont Apollo grounded in CEC test data and NEC 690.7/690.8 limits.
How many Du Pont Apollo DA105-A2 panels fit on a 600 V winter solar string?
At -10 C (14 F), Du Pont Apollo DA105-A2 cold Voc rises from 100.0 V to 111.48 V (beta_Voc -0.328%/C), capping a 600 V string at 5 panels (557.4 V).
How much roof area does an 8 kW array of Du Pont Apollo DA105-A2 need?
An 8 kW DC system uses 77 Du Pont Apollo DA105-A2 modules (8,085 W STC / 7,354 W PTC), covering roughly 1,276 sq ft and saving ~$2,025/yr at 18.54 c/kWh.
How does Du Pont Apollo DA105-A2 compare against Applied Materials 1/4 Size Single Junction Version 10?
Du Pont Apollo DA105-A2 outputs 105.0 W STC (100.0 V Voc, rank #21,543 of 21,677), while Applied Materials 1/4 Size Single Junction Version 10 delivers 116.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)