First Solar Inc FS-392-Plus is a 92.5 W STC (87.6 W PTC) Thin Film solar module ranking #21,589 of 21,677 CEC listings (below all-CEC median; higher than 0.4% of peers). It delivers 12.85% efficiency, 57.7 V Voc at 25 C, and 62.75 V cold Voc at -10 C (9 panels max per 600 V string).
- STC Wattage
- 92.5 W
- PTC Wattage
- 87.6 W
- Voc @ 25C
- 57.7 V
- Efficiency
- 12.85%
How Does First Solar Inc FS-392-Plus Compare Against Peer CEC Listings?
Solar engineering breakdown for First Solar Inc FS-392-Plus: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 106 Thin Film listings from First Solar Inc and peers, First Solar Inc FS-392-Plus stands 25.0 W below the 117.5 W Thin Film median and strong 94.7% PTC-to-STC heat retention (#2,085 of 21,677). Sizing 6 kW (65 panels) to 10 kW (109 panels) yields $1,504-$2,523/yr in baseline US bill offset. Higher 57.7 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C).
Where Does First Solar Inc FS-392-Plus Fall Across Listed CEC Models?
Distribution marker showing First Solar Inc FS-392-Plus (92.5 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define First Solar Inc FS-392-Plus?
Dataset percentiles tracking First Solar Inc FS-392-Plus power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for First Solar Inc FS-392-Plus?
Benchmark highlights for First Solar Inc FS-392-Plus covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
92.5 W STC · Higher Than 0.4%
92.5 W STC (-292.5 W vs all-CEC median) vs 117.5 W Thin Film median.
12.85% Aperture Efficiency
Power density 128.5 W/m2 (7.06 percentage points below 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).
9 Panels Max @ -10 C (600 V)
Cold Voc reaches 62.75 V at -10 C (564.8 V string) and 64.19 V at -20 C (9 max).
87 Panels = 8,048 W STC
Occupies 62.6 m2 (674 sq ft) producing 7,621 W PTC; NEC 690.8 OCPD floor is 3.56 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 57.7 * (1 + (-0.25/100) * (-10 - 25)) = 62.75 V | OCPD = 1.56 * 2.28 = 3.56 A
Inputs from CEC Modules.csv for First Solar Inc FS-392-Plus: Voc=57.7 V, beta_Voc=-0.25%/C, Isc=2.28 A, STC=92.5 W, Area=0.72 m2.
Result: 9 panels max on 600 V (564.8 V); 87 panels for 8 kW (674 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-392-Plus?
Official CEC datasheet figures for First Solar Inc FS-392-Plus (Thin Film) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 92.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 87.6 W (94.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 57.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.2 V / 2.05 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.25 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 12.85% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 146 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-392-Plus Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many First Solar Inc FS-392-Plus modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 65 | 6.01 kW | 504 sq ft | $1,504 | $2,544 |
| 8 kW Class | 87 | 8.05 kW | 674 sq ft | $2,015 | $3,407 |
| 10 kW Class | 109 | 10.08 kW | 845 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This First Solar Inc Series?
Consolidated First Solar Inc wattage variants sharing the First Solar Inc FS-392-Plus mechanical and cell layout. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| First Solar Inc FS-387-Plus | 87.5 W | 82.8 W | 56.0 V | 43.6 V | 12.15% |
| First Solar Inc FS-390-Plus | 90.0 W | 85.2 W | 56.9 V | 44.4 V | 12.5% |
| First Solar Inc FS-392-Plus | 92.5 W | 87.6 W | 57.7 V | 45.2 V | 12.85% |
| First Solar Inc FS-395-Plus | 95.0 W | 90.0 W | 58.0 V | 45.8 V | 13.19% |
| First Solar Inc FS-397-Plus | 97.5 W | 92.4 W | 58.6 V | 46.3 V | 13.54% |
How Many First Solar Inc FS-392-Plus Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-392-Plus (62.75 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 64.19 V | 9 panels | 577.7 V | 15 panels |
| -10 C (14 F) | 62.75 V | 9 panels | 564.8 V | 15 panels |
| 0 C (32 F) | 61.31 V | 9 panels | 551.8 V | 16 panels |
| 25 C (77 F STC) | 57.7 V | 10 panels | 577.0 V | 17 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-392-Plus?
Competing CEC solar panels closest to First Solar Inc FS-392-Plus in nameplate wattage and Voc, starting with Zhongshan Ruike New Energy Co Ltd RK-75-2.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Zhongshan Ruike New Energy Co Ltd RK-75-2 Zhongshan Ruike New Energy Co Ltd |
75.0 W | -17.5 W | 58.5 V | 10.42% | 93.9% |
| Centrosolar America VS-140C1 Centrosolar America |
140.0 W | +47.5 W | 60.6 V | 12.89% | 92.7% |
| Miasole FLEX-03 120N Miasole |
115.1 W | +22.6 W | 37.8 V | 12.82% | 90.9% |
| Tesla Inc SR86T3R Tesla Inc |
86.0 W | -6.5 W | 26.6 V | 17.92% | 89.9% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-392-Plus?
Evaluate First Solar Inc FS-392-Plus (92.5 W STC, 57.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-392-Plus reaches 64.19 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 87 panels for an 8 kW build require 674 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 87 panels (674 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-392-Plus carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-392-Plus 8 kW Residential Fit
Needs 87 modules (674 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Zhongshan Ruike New Energy Co Ltd RK-75-2.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 87.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-392-Plus by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-392-Plus?
Multiplying First Solar Inc FS-392-Plus's 2.28 A short-circuit current by 1.56 equals 3.56 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-392-Plus pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 62.75 V cold Voc at 14 F and handles 2.28 A Isc; string inverters cap First Solar Inc FS-392-Plus at 9 panels on 600 V.
Is First Solar Inc FS-392-Plus eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-392-Plus rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)