First Solar Inc FS-392-Plus — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-392-Plus is a 92.5 W STC (87.6 W PTC) Thin Film solar module ranking #21,589 of 21,677 CEC listings (below all-CEC median; higher than 0.4% of peers). It delivers 12.85% efficiency, 57.7 V Voc at 25 C, and 62.75 V cold Voc at -10 C (9 panels max per 600 V string).

STC Wattage
92.5 W
PTC Wattage
87.6 W
Voc @ 25C
57.7 V
Efficiency
12.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-392-Plus Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-392-Plus: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 106 Thin Film listings from First Solar Inc and peers, First Solar Inc FS-392-Plus stands 25.0 W below the 117.5 W Thin Film median and strong 94.7% PTC-to-STC heat retention (#2,085 of 21,677). Sizing 6 kW (65 panels) to 10 kW (109 panels) yields $1,504-$2,523/yr in baseline US bill offset. Higher 57.7 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C).

Where Does First Solar Inc FS-392-Plus Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-392-Plus (92.5 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-392-Plus (92.5 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 92.5 W

What Dataset Percentiles Define First Solar Inc FS-392-Plus?

Dataset percentiles tracking First Solar Inc FS-392-Plus power output, thermal retention ratio, and aperture efficiency against 21,677 models.

First Solar Inc FS-392-Plus Engineering BenchmarksPercentile comparison of First Solar Inc FS-392-Plus wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage92.5 WPTC/STC Retention94.7%Module Efficiency12.85%

What Do the Dataset Ranks Show for First Solar Inc FS-392-Plus?

Benchmark highlights for First Solar Inc FS-392-Plus covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,589 / 21,677

92.5 W STC · Higher Than 0.4%

92.5 W STC (-292.5 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,459

12.85% Aperture Efficiency

Power density 128.5 W/m2 (7.06 percentage points below 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).

NEC 690.7 Limit

9 Panels Max @ -10 C (600 V)

Cold Voc reaches 62.75 V at -10 C (564.8 V string) and 64.19 V at -20 C (9 max).

8 kW Reference Array

87 Panels = 8,048 W STC

Occupies 62.6 m2 (674 sq ft) producing 7,621 W PTC; NEC 690.8 OCPD floor is 3.56 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 57.7 * (1 + (-0.25/100) * (-10 - 25)) = 62.75 V | OCPD = 1.56 * 2.28 = 3.56 A

Inputs from CEC Modules.csv for First Solar Inc FS-392-Plus: Voc=57.7 V, beta_Voc=-0.25%/C, Isc=2.28 A, STC=92.5 W, Area=0.72 m2.

Result: 9 panels max on 600 V (564.8 V); 87 panels for 8 kW (674 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-392-Plus?

Official CEC datasheet figures for First Solar Inc FS-392-Plus (Thin Film) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-392-Plus.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 92.5 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 87.6 W (94.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 57.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.28 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 45.2 V / 2.05 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.25 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 12.85% (0.72 m2) Array roof footprint density
Cell Count & Technology 146 cells (Thin Film) Monofacial backsheet

How Many First Solar Inc FS-392-Plus Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-392-Plus modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 65 6.01 kW 504 sq ft $1,504 $2,544
8 kW Class 87 8.05 kW 674 sq ft $2,015 $3,407
10 kW Class 109 10.08 kW 845 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This First Solar Inc Series?

Consolidated First Solar Inc wattage variants sharing the First Solar Inc FS-392-Plus mechanical and cell layout. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the First Solar Inc FS-392-Plus wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
First Solar Inc FS-387-Plus 87.5 W 82.8 W 56.0 V 43.6 V 12.15%
First Solar Inc FS-390-Plus 90.0 W 85.2 W 56.9 V 44.4 V 12.5%
First Solar Inc FS-392-Plus 92.5 W 87.6 W 57.7 V 45.2 V 12.85%
First Solar Inc FS-395-Plus 95.0 W 90.0 W 58.0 V 45.8 V 13.19%
First Solar Inc FS-397-Plus 97.5 W 92.4 W 58.6 V 46.3 V 13.54%

How Many First Solar Inc FS-392-Plus Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-392-Plus (62.75 V at 14 F).

Computed from Voc=57.7V and beta_Voc=-0.25%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 64.19 V 9 panels 577.7 V 15 panels
-10 C (14 F) 62.75 V 9 panels 564.8 V 15 panels
0 C (32 F) 61.31 V 9 panels 551.8 V 16 panels
25 C (77 F STC) 57.7 V 10 panels 577.0 V 17 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-392-Plus?

Competing CEC solar panels closest to First Solar Inc FS-392-Plus in nameplate wattage and Voc, starting with Zhongshan Ruike New Energy Co Ltd RK-75-2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Zhongshan Ruike New Energy Co Ltd RK-75-2
Zhongshan Ruike New Energy Co Ltd
75.0 W -17.5 W 58.5 V 10.42% 93.9%
Centrosolar America VS-140C1
Centrosolar America
140.0 W +47.5 W 60.6 V 12.89% 92.7%
Miasole FLEX-03 120N
Miasole
115.1 W +22.6 W 37.8 V 12.82% 90.9%
Tesla Inc SR86T3R
Tesla Inc
86.0 W -6.5 W 26.6 V 17.92% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-392-Plus?

Evaluate First Solar Inc FS-392-Plus (92.5 W STC, 57.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-392-Plus reaches 64.19 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 87 panels for an 8 kW build require 674 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 87 panels (674 sq ft).
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-392-Plus carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-392-Plus 8 kW Residential Fit

Needs 87 modules (674 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Zhongshan Ruike New Energy Co Ltd RK-75-2.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 87.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-392-Plus by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-392-Plus?

Multiplying First Solar Inc FS-392-Plus's 2.28 A short-circuit current by 1.56 equals 3.56 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can First Solar Inc FS-392-Plus pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 62.75 V cold Voc at 14 F and handles 2.28 A Isc; string inverters cap First Solar Inc FS-392-Plus at 9 panels on 600 V.

Is First Solar Inc FS-392-Plus eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-392-Plus rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.