Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Trystar LLC: OZPCS-RS40-BB1 {480V} — CEC Inverter Specifications

Manufacturer: Trystar LLC Registry: CEC Verified Engineering Specification

Trystar LLC: OZPCS-RS40-BB1 {480V} outputs 39,540 W AC at 480 V, 3-phase (47.6 A continuous, 60 A OCPD), ranking #1,217 of 2,343 CEC inverters at 96.77% efficiency with a 550-820 V MPPT window and 820 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
39,540 W
AC Voltage
480 V, 3-phase
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
96.77%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trystar LLC: OZPCS-RS40-BB1 {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for Trystar LLC: OZPCS-RS40-BB1 {480V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rated at 39,540 W AC (47.6 A continuous), Trystar LLC: OZPCS-RS40-BB1 {480V} ranks #1,217 of 2,343 CEC units at 96.77% efficiency (-1.25 pts vs the 98.02% 480 V median). Minimum 75 C copper conductor sizing for its 60 A circuit is 6 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 820 V DC at record local winter lows.

Where Does Trystar LLC: OZPCS-RS40-BB1 {480V} Fall Across Listed CEC Models?

Marks Trystar LLC: OZPCS-RS40-BB1 {480V} (39,540 W AC) across the California Energy Commission inverter AC capacity distribution. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Trystar LLC: OZPCS-RS40-BB1 {480V} (39,540 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACTrystar LLC: OZPCS: 39,540 W

What Dataset Percentiles Define Trystar LLC: OZPCS-RS40-BB1 {480V}?

Benchmarks Trystar LLC: OZPCS-RS40-BB1 {480V} continuous AC output, 96.77% CEC weighted efficiency, and 60 A OCPD breaker demand.

Trystar LLC: OZPCS-RS40-BB1 {480V} Technical ThresholdsPercentile comparison for Trystar LLC: OZPCS-RS40-BB1 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output39,540 WCEC Efficiency96.77%Backfeed Breaker60 A

What Do the Dataset Ranks Show for Trystar LLC: OZPCS-RS40-BB1 {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining Trystar LLC: OZPCS-RS40-BB1 {480V} by Trystar LLC. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Eff #1,217 / 2,343

96.77% CEC Weighted Efficiency

-1.25 pts vs the 98.02% 480 V median; overall power rank #506 (39,540 W, top 21.7%; higher than 78.3% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 47.6 A = 59.5 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

550 V - 820 V (Max 820 V DC)

Tracking span of 270.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 39540.0W / 480 V 3-phase -> 47.6 A | Breaker >= 1.25 * 47.6 = 59.5 A -> 60 A

CEC Inverters.csv for Trystar LLC: OZPCS-RS40-BB1 {480V}: Paco=39540.0 W, Vac=480 V, Vdcmax=820.0 V, Eff=96.77%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Trystar LLC: OZPCS-RS40-BB1 {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Trystar LLC: OZPCS-RS40-BB1 {480V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for Trystar LLC: OZPCS-RS40-BB1 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 39,540 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 820 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 550 V - 820 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 58.3686 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.77% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Trystar LLC: OZPCS-RS40-BB1 {480V} (480 V, 3-phase)?

Evaluates Trystar LLC: OZPCS-RS40-BB1 {480V} (60 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Trystar LLC: OZPCS-RS40-BB1 {480V} (60 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 60 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 60 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 60 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 60 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 60 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Trystar LLC: OZPCS-RS40-BB1 {480V}?

Sample PV string lengths aligned within 550-820 V MPPT and 820 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 550.0-820.0 V MPPT and 820.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 13 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 17 to 19 panels 8.36 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 16 to 18 panels 7.65 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 20 panels (fixed) 4.0 kW

Which Competing Grid-Support Inverters Compare to Trystar LLC: OZPCS-RS40-BB1 {480V}?

Competing CEC grid-support inverters near 39,540 W AC and 480 V, 3-phase, led by Delta Electronics: M36U_120 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: M36U_120 {480V}
Delta Electronics
39,737 W +197 W 480.0 V 830.0 V 97.97%
Delta Electronics: M36U_121 {480V}
Delta Electronics
39,737 W +197 W 480.0 V 830.0 V 97.97%
Delta Electronics: M36U_122 {480V}
Delta Electronics
39,737 W +197 W 480.0 V 830.0 V 97.97%
CSI Solar Co Ltd: CSI-40K-T480GL03-U {480V}
CSI Solar Co Ltd
39,841 W +301 W 480.0 V 850.0 V 98.02%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Trystar LLC: OZPCS-RS40-BB1 {480V}?

Check Trystar LLC: OZPCS-RS40-BB1 {480V} (39,540 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 820 V DC on Trystar LLC: OZPCS-RS40-BB1 {480V}.

Trystar LLC: OZPCS-RS40-BB1 {480V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.77%) and MPPT window (550-820 V) directly against Delta Electronics: M36U_120 {480V} (39,737 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Trystar LLC: OZPCS-RS40-BB1 {480V} by Trystar LLC covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Trystar LLC: OZPCS-RS40-BB1 {480V} require?

At 39,540 W continuous AC (480 V, 3-phase), continuous current is 47.6 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Trystar LLC: OZPCS-RS40-BB1 {480V} require?

At 39,540 W AC and 480 V, 3-phase, continuous line current is 47.6 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Trystar LLC: OZPCS-RS40-BB1 {480V} compare to Delta Electronics: M36U_120 {480V}?

Trystar LLC: OZPCS-RS40-BB1 {480V} delivers 39,540 W AC at 96.77% CEC efficiency with a 820 V DC ceiling, while Delta Electronics: M36U_120 {480V} outputs 39,737 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.