Delta Electronics: M36U_120 {480V} outputs 39,737 W AC at 480 V, 3-phase (47.8 A continuous, 60 A OCPD), ranking #357 of 2,343 CEC inverters at 97.97% efficiency with a 520-830 V MPPT window and 830 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 39,737 W
- AC Voltage
- 480 V, 3-phase
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 97.97%
How Does Delta Electronics: M36U_120 {480V} Compare Against Peer CEC Listings?
How Delta Electronics Delta Electronics: M36U_120 {480V} compares on 97.97% efficiency, MPPT span, and 120% busbar interconnection.
Delta Electronics certifies Delta Electronics: M36U_120 {480V} (grid-tied PV inverter, listed since 2020-11-12) at 39,737 W AC (10,263 W below the 50,000 W 480 V median). Its 830 V DC ceiling pairs with an MPPT window of 520-830 V (span 310.0 V). Under NEC 690.8/705.12, 125% sizing demands 6 AWG Cu conductors on a 60 A OCPD.
Where Does Delta Electronics: M36U_120 {480V} Fall Across Listed CEC Models?
Position of Delta Electronics: M36U_120 {480V} (39,737 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Delta Electronics: M36U_120 {480V}?
Percentile placement of Delta Electronics: M36U_120 {480V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Delta Electronics: M36U_120 {480V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Delta Electronics: M36U_120 {480V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
97.97% CEC Weighted Efficiency
-0.05 pts vs the 98.02% 480 V median; overall power rank #503 (39,737 W, top 21.6%; higher than 78.4% of peers).
60 A Required Backfeed OCPD
125% x 47.8 A = 59.8 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
520 V - 830 V (Max 830 V DC)
Tracking span of 310.0 V; listed since 2020-11-12 (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 39737.0W / 480 V 3-phase -> 47.8 A | Breaker >= 1.25 * 47.8 = 59.8 A -> 60 A
CEC Inverters.csv for Delta Electronics: M36U_120 {480V}: Paco=39737.0 W, Vac=480 V, Vdcmax=830.0 V, Eff=97.97%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Delta Electronics: M36U_120 {480V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Delta Electronics: M36U_120 {480V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 39,737 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 830 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 520 V - 830 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 57.1281 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.97% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2020-11-12 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Delta Electronics: M36U_120 {480V} (480 V, 3-phase)?
Check whether Delta Electronics: M36U_120 {480V} (60 A breaker) fits without main breaker derate or supply-side taps.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (480V) | 40 A | 60 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (480V) | 80 A | 60 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (480V) | 120 A | 60 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (480V) | 160 A | 60 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (480V) | 240 A | 60 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Delta Electronics: M36U_120 {480V}?
Verified cold-weather (-10 C) series module counts matched to Delta Electronics: M36U_120 {480V}'s 830 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 13 to 14 panels | 8.26 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 16 to 19 panels | 8.36 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 16 to 18 panels | 7.65 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 18 to 20 panels | 4.0 kW |
Which Competing Grid-Support Inverters Compare to Delta Electronics: M36U_120 {480V}?
Alternative CEC inverters comparable to Delta Electronics: M36U_120 {480V}, including CSI Solar Co Ltd: CSI-40K-T480GL03-U {480V} (39,841 W) at 480 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| CSI Solar Co Ltd: CSI-40K-T480GL03-U {480V} CSI Solar Co Ltd |
39,841 W | +104 W | 480.0 V | 850.0 V | 98.02% |
| Fortress Power LLC: FP-Nano-40k-N {480V} Fortress Power LLC |
39,844 W | +107 W | 480.0 V | 850.0 V | 97.38% |
| CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V} CSI Solar Co Ltd |
39,926 W | +189 W | 480.0 V | 800.0 V | 98.34% |
| Canadian Solar Inc: CSI-40KTL-GS {480V} Canadian Solar Inc |
40,000 W | +263 W | 480.0 V | 780.0 V | 98.0% |
What Are the Interconnection Limits and Best-Fit Uses for Delta Electronics: M36U_120 {480V}?
Check Delta Electronics: M36U_120 {480V} (39,737 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 830 V DC on Delta Electronics: M36U_120 {480V}.
Delta Electronics: M36U_120 {480V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.8 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.97%) and MPPT window (520-830 V) directly against CSI Solar Co Ltd: CSI-40K-T480GL03-U {480V} (39,841 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Delta Electronics: M36U_120 {480V} by Delta Electronics covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.
What breaker and wire size does Delta Electronics: M36U_120 {480V} require?
At 39,737 W continuous AC (480 V, 3-phase), continuous current is 47.8 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Delta Electronics: M36U_120 {480V} require?
At 39,737 W AC and 480 V, 3-phase, continuous line current is 47.8 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.
How does Delta Electronics: M36U_120 {480V} compare to CSI Solar Co Ltd: CSI-40K-T480GL03-U {480V}?
Delta Electronics: M36U_120 {480V} delivers 39,737 W AC at 97.97% CEC efficiency with a 830 V DC ceiling, while CSI Solar Co Ltd: CSI-40K-T480GL03-U {480V} outputs 39,841 W at 480 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)