Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Trystar LLC: OZPCS-RS35-FB0 {208V} — CEC Inverter Specifications

Manufacturer: Trystar LLC Registry: CEC Verified Engineering Specification

Trystar LLC: OZPCS-RS35-FB0 {208V} outputs 34,332 W AC at 208 V, 3-phase (95.3 A continuous, 125 A OCPD), ranking #2,236 of 2,343 CEC inverters at 95.2% efficiency with a 400-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
34,332 W
AC Voltage
208 V, 3-phase
Min PV Breaker
125 A (1 AWG Cu)
CEC Efficiency
95.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trystar LLC: OZPCS-RS35-FB0 {208V} Compare Against Peer CEC Listings?

How Trystar LLC Trystar LLC: OZPCS-RS35-FB0 {208V} compares on 95.2% efficiency, MPPT span, and 120% busbar interconnection. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Trystar LLC certifies Trystar LLC: OZPCS-RS35-FB0 {208V} (grid-tied PV inverter, active in CEC directory) at 34,332 W AC (29,332 W above the 5,000 W 208 V median). Its 800 V DC ceiling pairs with an MPPT window of 400-800 V (span 400.0 V). Under NEC 690.8/705.12, 125% sizing demands 1 AWG Cu conductors on a 125 A OCPD.

Where Does Trystar LLC: OZPCS-RS35-FB0 {208V} Fall Across Listed CEC Models?

Position of Trystar LLC: OZPCS-RS35-FB0 {208V} (34,332 W AC) relative to the 7,680 W CEC median inverter. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Trystar LLC: OZPCS-RS35-FB0 {208V} (34,332 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACTrystar LLC: OZPCS: 34,332 W

What Dataset Percentiles Define Trystar LLC: OZPCS-RS35-FB0 {208V}?

Percentile placement of Trystar LLC: OZPCS-RS35-FB0 {208V} across AC power class, conversion efficiency, and backfeed breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Trystar LLC: OZPCS-RS35-FB0 {208V} Technical ThresholdsPercentile comparison for Trystar LLC: OZPCS-RS35-FB0 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output34,332 WCEC Efficiency95.2%Backfeed Breaker125 A

What Do the Dataset Ranks Show for Trystar LLC: OZPCS-RS35-FB0 {208V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Trystar LLC: OZPCS-RS35-FB0 {208V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Eff #2,236 / 2,343

95.2% CEC Weighted Efficiency

-1.21 pts vs the 96.41% 208 V median; overall power rank #531 (34,332 W, top 22.7%; higher than 77.3% of peers).

NEC 705.12 Check

125 A Required Backfeed OCPD

125% x 95.3 A = 119.1 A -> 125 A standard OCPD using 1 AWG Cu (75 C).

MPPT Window

400 V - 800 V (Max 800 V DC)

Tracking span of 400.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 34331.7W / 208 V 3-phase -> 95.3 A | Breaker >= 1.25 * 95.3 = 119.1 A -> 125 A

CEC Inverters.csv for Trystar LLC: OZPCS-RS35-FB0 {208V}: Paco=34331.7 W, Vac=208 V, Vdcmax=800.0 V, Eff=95.2%.

Result: Min 125 A breaker & 1 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Trystar LLC: OZPCS-RS35-FB0 {208V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Trystar LLC: OZPCS-RS35-FB0 {208V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Trystar LLC: OZPCS-RS35-FB0 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 34,332 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 400 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 60.1045 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.2% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Trystar LLC: OZPCS-RS35-FB0 {208V} (208 V, 3-phase)?

Check whether Trystar LLC: OZPCS-RS35-FB0 {208V} (125 A breaker) fits without main breaker derate or supply-side taps. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Evaluates Trystar LLC: OZPCS-RS35-FB0 {208V} (125 A required OCPD at 208 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (208V) 120 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (208V) 160 A 125 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 125 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Trystar LLC: OZPCS-RS35-FB0 {208V}?

Verified cold-weather (-10 C) series module counts matched to Trystar LLC: OZPCS-RS35-FB0 {208V}'s 800 V DC ceiling.

Sampled CEC PV modules aligned within 400.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 10 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 12 to 18 panels 7.92 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 12 to 17 panels 7.22 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 14 to 19 panels 3.8 kW

Which Competing Grid-Support Inverters Compare to Trystar LLC: OZPCS-RS35-FB0 {208V}?

Alternative CEC inverters comparable to Trystar LLC: OZPCS-RS35-FB0 {208V}, including CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} (29,878 W) at 208 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}
CSI Solar Co Ltd
29,878 W -4454 W 208.0 V 680.0 V 96.38%
Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}
Chint Power Systems America
25,000 W -9332 W 208.0 V 850.0 V 96.26%
EcoFlow Inc: EF-PCS-24 {208V 24kW}
EcoFlow Inc
24,291 W -10040 W 208.0 V 480.0 V 96.01%
Chint Power Systems America: SCA50K-T-US-208 {208V}
Chint Power Systems America
50,000 W +15668 W 208.0 V 700.0 V 95.93%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Trystar LLC: OZPCS-RS35-FB0 {208V}?

Check Trystar LLC: OZPCS-RS35-FB0 {208V} (34,332 W AC, 125 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on Trystar LLC: OZPCS-RS35-FB0 {208V}.

Trystar LLC: OZPCS-RS35-FB0 {208V} Panel & Wire Spec

Size 75 C copper conductors at 1 AWG Cu on a 125 A OCPD breaker (95.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.2%) and MPPT window (400-800 V) directly against CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} (29,878 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Trystar LLC: OZPCS-RS35-FB0 {208V} by Trystar LLC covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.

What breaker and wire size does Trystar LLC: OZPCS-RS35-FB0 {208V} require?

At 34,332 W continuous AC (208 V, 3-phase), continuous current is 95.3 A; 125% NEC 690.8/705.12 sizing requires a 125 A breaker and 1 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Trystar LLC: OZPCS-RS35-FB0 {208V} require?

At 34,332 W AC and 208 V, 3-phase, continuous line current is 95.3 A, requiring a 125 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Trystar LLC: OZPCS-RS35-FB0 {208V} compare to CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}?

Trystar LLC: OZPCS-RS35-FB0 {208V} delivers 34,332 W AC at 95.2% CEC efficiency with a 800 V DC ceiling, while CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} outputs 29,878 W at 208 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.