Trystar LLC: OZPCS-RS35-FB0 {208V} outputs 34,332 W AC at 208 V, 3-phase (95.3 A continuous, 125 A OCPD), ranking #2,236 of 2,343 CEC inverters at 95.2% efficiency with a 400-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 34,332 W
- AC Voltage
- 208 V, 3-phase
- Min PV Breaker
- 125 A (1 AWG Cu)
- CEC Efficiency
- 95.2%
How Does Trystar LLC: OZPCS-RS35-FB0 {208V} Compare Against Peer CEC Listings?
How Trystar LLC Trystar LLC: OZPCS-RS35-FB0 {208V} compares on 95.2% efficiency, MPPT span, and 120% busbar interconnection. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Trystar LLC certifies Trystar LLC: OZPCS-RS35-FB0 {208V} (grid-tied PV inverter, active in CEC directory) at 34,332 W AC (29,332 W above the 5,000 W 208 V median). Its 800 V DC ceiling pairs with an MPPT window of 400-800 V (span 400.0 V). Under NEC 690.8/705.12, 125% sizing demands 1 AWG Cu conductors on a 125 A OCPD.
Where Does Trystar LLC: OZPCS-RS35-FB0 {208V} Fall Across Listed CEC Models?
Position of Trystar LLC: OZPCS-RS35-FB0 {208V} (34,332 W AC) relative to the 7,680 W CEC median inverter. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Dataset Percentiles Define Trystar LLC: OZPCS-RS35-FB0 {208V}?
Percentile placement of Trystar LLC: OZPCS-RS35-FB0 {208V} across AC power class, conversion efficiency, and backfeed breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Do the Dataset Ranks Show for Trystar LLC: OZPCS-RS35-FB0 {208V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Trystar LLC: OZPCS-RS35-FB0 {208V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
95.2% CEC Weighted Efficiency
-1.21 pts vs the 96.41% 208 V median; overall power rank #531 (34,332 W, top 22.7%; higher than 77.3% of peers).
125 A Required Backfeed OCPD
125% x 95.3 A = 119.1 A -> 125 A standard OCPD using 1 AWG Cu (75 C).
400 V - 800 V (Max 800 V DC)
Tracking span of 400.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 34331.7W / 208 V 3-phase -> 95.3 A | Breaker >= 1.25 * 95.3 = 119.1 A -> 125 A
CEC Inverters.csv for Trystar LLC: OZPCS-RS35-FB0 {208V}: Paco=34331.7 W, Vac=208 V, Vdcmax=800.0 V, Eff=95.2%.
Result: Min 125 A breaker & 1 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Trystar LLC: OZPCS-RS35-FB0 {208V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Trystar LLC: OZPCS-RS35-FB0 {208V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 34,332 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 800 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 400 V - 800 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 60.1045 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 95.2% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to Trystar LLC: OZPCS-RS35-FB0 {208V} (208 V, 3-phase)?
Check whether Trystar LLC: OZPCS-RS35-FB0 {208V} (125 A breaker) fits without main breaker derate or supply-side taps. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 125 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (208V) | 80 A | 125 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (208V) | 120 A | 125 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (208V) | 160 A | 125 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 125 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Trystar LLC: OZPCS-RS35-FB0 {208V}?
Verified cold-weather (-10 C) series module counts matched to Trystar LLC: OZPCS-RS35-FB0 {208V}'s 800 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 10 to 14 panels | 8.26 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 12 to 18 panels | 7.92 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 12 to 17 panels | 7.22 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 14 to 19 panels | 3.8 kW |
Which Competing Grid-Support Inverters Compare to Trystar LLC: OZPCS-RS35-FB0 {208V}?
Alternative CEC inverters comparable to Trystar LLC: OZPCS-RS35-FB0 {208V}, including CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} (29,878 W) at 208 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} CSI Solar Co Ltd |
29,878 W | -4454 W | 208.0 V | 680.0 V | 96.38% |
| Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V} Chint Power Systems America |
25,000 W | -9332 W | 208.0 V | 850.0 V | 96.26% |
| EcoFlow Inc: EF-PCS-24 {208V 24kW} EcoFlow Inc |
24,291 W | -10040 W | 208.0 V | 480.0 V | 96.01% |
| Chint Power Systems America: SCA50K-T-US-208 {208V} Chint Power Systems America |
50,000 W | +15668 W | 208.0 V | 700.0 V | 95.93% |
What Are the Interconnection Limits and Best-Fit Uses for Trystar LLC: OZPCS-RS35-FB0 {208V}?
Check Trystar LLC: OZPCS-RS35-FB0 {208V} (34,332 W AC, 125 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on Trystar LLC: OZPCS-RS35-FB0 {208V}.
Trystar LLC: OZPCS-RS35-FB0 {208V} Panel & Wire Spec
Size 75 C copper conductors at 1 AWG Cu on a 125 A OCPD breaker (95.3 A continuous).
Alternative Inverter Comparison
Compare efficiency (95.2%) and MPPT window (400-800 V) directly against CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} (29,878 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Trystar LLC: OZPCS-RS35-FB0 {208V} by Trystar LLC covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.
What breaker and wire size does Trystar LLC: OZPCS-RS35-FB0 {208V} require?
At 34,332 W continuous AC (208 V, 3-phase), continuous current is 95.3 A; 125% NEC 690.8/705.12 sizing requires a 125 A breaker and 1 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Trystar LLC: OZPCS-RS35-FB0 {208V} require?
At 34,332 W AC and 208 V, 3-phase, continuous line current is 95.3 A, requiring a 125 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Trystar LLC: OZPCS-RS35-FB0 {208V} compare to CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}?
Trystar LLC: OZPCS-RS35-FB0 {208V} delivers 34,332 W AC at 95.2% CEC efficiency with a 800 V DC ceiling, while CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} outputs 29,878 W at 208 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)