Trystar LLC: OZPCS-RS40-BB1 {208V} outputs 17,230 W AC at 208 V, 3-phase (47.8 A continuous, 60 A OCPD), ranking #2,305 of 2,343 CEC inverters at 94.25% efficiency with a 550-820 V MPPT window and 820 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 17,230 W
- AC Voltage
- 208 V, 3-phase
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 94.25%
How Does Trystar LLC: OZPCS-RS40-BB1 {208V} Compare Against Peer CEC Listings?
Breaker sizing (60 A), 6 AWG Cu wire rules, and DC input limits for Trystar LLC: OZPCS-RS40-BB1 {208V}.
For NEC 705.12 solar interconnection, Trystar LLC: OZPCS-RS40-BB1 {208V} outputs 47.8 A continuous AC at 208 V, 3-phase and needs a 60 A backfeed breaker on 6 AWG Cu (75 C). Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Conversion efficiency scores 94.25% (#2,305 of 2,343, -2.57 pts vs overall CEC median).
Where Does Trystar LLC: OZPCS-RS40-BB1 {208V} Fall Across Listed CEC Models?
Output power comparison showing where Trystar LLC: OZPCS-RS40-BB1 {208V} sits among all 2,343 CEC-listed grid-support inverters. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Trystar LLC: OZPCS-RS40-BB1 {208V}?
Relative ranking of Trystar LLC: OZPCS-RS40-BB1 {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for Trystar LLC: OZPCS-RS40-BB1 {208V}?
Snapshot of Trystar LLC: OZPCS-RS40-BB1 {208V} efficiency rank (#2,305), OCPD breaker size, MPPT span, and busbar verdict. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
94.25% CEC Weighted Efficiency
-2.16 pts vs the 96.41% 208 V median; overall power rank #642 (17,230 W, top 27.5%; higher than 72.5% of peers).
60 A Required Backfeed OCPD
125% x 47.8 A = 59.8 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
550 V - 820 V (Max 820 V DC)
Tracking span of 270.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 17229.9W / 208 V 3-phase -> 47.8 A | Breaker >= 1.25 * 47.8 = 59.8 A -> 60 A
CEC Inverters.csv for Trystar LLC: OZPCS-RS40-BB1 {208V}: Paco=17229.9 W, Vac=208 V, Vdcmax=820.0 V, Eff=94.25%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Trystar LLC: OZPCS-RS40-BB1 {208V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Trystar LLC: OZPCS-RS40-BB1 {208V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 17,230 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 820 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 550 V - 820 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 26.1152 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 94.25% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to Trystar LLC: OZPCS-RS40-BB1 {208V} (208 V, 3-phase)?
NEC 705.12(B)(3)(2) backfeed compliance table for Trystar LLC: OZPCS-RS40-BB1 {208V} at 208 V, 3-phase. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 60 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (208V) | 80 A | 60 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 60 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 60 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 60 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Trystar LLC: OZPCS-RS40-BB1 {208V}?
Minimum and maximum series solar module strings fitting Trystar LLC: OZPCS-RS40-BB1 {208V} MPPT and 820 V limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 13 to 14 panels | 8.26 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 17 to 19 panels | 8.36 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 16 to 18 panels | 7.65 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 20 panels (fixed) | 4.0 kW |
Which Competing Grid-Support Inverters Compare to Trystar LLC: OZPCS-RS40-BB1 {208V}?
Peer 208 V, 3-phase CEC inverters near 17,230 W AC output such as EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} EG4 Electronics LLC |
13,899 W | -3331 W | 208.0 V | 440.0 V | 96.46% |
| Chint Power Systems America: CPS ECH12KTL/US {208V} Chint Power Systems America |
12,000 W | -5230 W | 208.0 V | 480.0 V | 96.63% |
| EcoFlow Inc: EF-PCS-24 {208V 115kW} EcoFlow Inc |
11,444 W | -5786 W | 208.0 V | 480.0 V | 96.52% |
| Chint Power Systems America: CPS ECH114KTL/US {208V} Chint Power Systems America |
11,350 W | -5880 W | 208.0 V | 480.0 V | 96.63% |
What Are the Interconnection Limits and Best-Fit Uses for Trystar LLC: OZPCS-RS40-BB1 {208V}?
Check Trystar LLC: OZPCS-RS40-BB1 {208V} (17,230 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 820 V DC on Trystar LLC: OZPCS-RS40-BB1 {208V}.
Trystar LLC: OZPCS-RS40-BB1 {208V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.8 A continuous).
Alternative Inverter Comparison
Compare efficiency (94.25%) and MPPT window (550-820 V) directly against EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} (13,899 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Trystar LLC: OZPCS-RS40-BB1 {208V} by Trystar LLC covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.
What breaker and wire size does Trystar LLC: OZPCS-RS40-BB1 {208V} require?
At 17,230 W continuous AC (208 V, 3-phase), continuous current is 47.8 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Trystar LLC: OZPCS-RS40-BB1 {208V} require?
At 17,230 W AC and 208 V, 3-phase, continuous line current is 47.8 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Trystar LLC: OZPCS-RS40-BB1 {208V} compare to EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}?
Trystar LLC: OZPCS-RS40-BB1 {208V} delivers 17,230 W AC at 94.25% CEC efficiency with a 820 V DC ceiling, while EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} outputs 13,899 W at 208 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)