Trystar LLC: OZPCS-RS35-FB1 {208V} — CEC Inverter Specifications

Manufacturer: Trystar LLC Registry: CEC Verified Engineering Specification

Trystar LLC: OZPCS-RS35-FB1 {208V} outputs 34,332 W AC at 208 V, 3-phase (95.3 A continuous, 125 A OCPD), ranking #2,236 of 2,343 CEC inverters at 95.2% efficiency with a 400-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
34,332 W
AC Voltage
208 V, 3-phase
Min PV Breaker
125 A (1 AWG Cu)
CEC Efficiency
95.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trystar LLC: OZPCS-RS35-FB1 {208V} Compare Against Peer CEC Listings?

Breaker sizing (125 A), 1 AWG Cu wire rules, and DC input limits for Trystar LLC: OZPCS-RS35-FB1 {208V}.

For NEC 705.12 solar interconnection, Trystar LLC: OZPCS-RS35-FB1 {208V} outputs 95.3 A continuous AC at 208 V, 3-phase and needs a 125 A backfeed breaker on 1 AWG Cu (75 C). Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Conversion efficiency scores 95.2% (#2,236 of 2,343, -1.62 pts vs overall CEC median).

Where Does Trystar LLC: OZPCS-RS35-FB1 {208V} Fall Across Listed CEC Models?

Output power comparison showing where Trystar LLC: OZPCS-RS35-FB1 {208V} sits among all 2,343 CEC-listed grid-support inverters. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Trystar LLC: OZPCS-RS35-FB1 {208V} (34,332 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACTrystar LLC: OZPCS: 34,332 W

What Dataset Percentiles Define Trystar LLC: OZPCS-RS35-FB1 {208V}?

Relative ranking of Trystar LLC: OZPCS-RS35-FB1 {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Trystar LLC: OZPCS-RS35-FB1 {208V} Technical ThresholdsPercentile comparison for Trystar LLC: OZPCS-RS35-FB1 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output34,332 WCEC Efficiency95.2%Backfeed Breaker125 A

What Do the Dataset Ranks Show for Trystar LLC: OZPCS-RS35-FB1 {208V}?

Snapshot of Trystar LLC: OZPCS-RS35-FB1 {208V} efficiency rank (#2,236), OCPD breaker size, MPPT span, and busbar verdict. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Eff #2,236 / 2,343

95.2% CEC Weighted Efficiency

-1.21 pts vs the 96.41% 208 V median; overall power rank #531 (34,332 W, top 22.7%; higher than 77.3% of peers).

NEC 705.12 Check

125 A Required Backfeed OCPD

125% x 95.3 A = 119.1 A -> 125 A standard OCPD using 1 AWG Cu (75 C).

MPPT Window

400 V - 800 V (Max 800 V DC)

Tracking span of 400.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 34331.7W / 208 V 3-phase -> 95.3 A | Breaker >= 1.25 * 95.3 = 119.1 A -> 125 A

CEC Inverters.csv for Trystar LLC: OZPCS-RS35-FB1 {208V}: Paco=34331.7 W, Vac=208 V, Vdcmax=800.0 V, Eff=95.2%.

Result: Min 125 A breaker & 1 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Trystar LLC: OZPCS-RS35-FB1 {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Trystar LLC: OZPCS-RS35-FB1 {208V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Trystar LLC: OZPCS-RS35-FB1 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 34,332 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 400 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 60.1045 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.2% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Trystar LLC: OZPCS-RS35-FB1 {208V} (208 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Trystar LLC: OZPCS-RS35-FB1 {208V} at 208 V, 3-phase. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Evaluates Trystar LLC: OZPCS-RS35-FB1 {208V} (125 A required OCPD at 208 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (208V) 120 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (208V) 160 A 125 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 125 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Trystar LLC: OZPCS-RS35-FB1 {208V}?

Minimum and maximum series solar module strings fitting Trystar LLC: OZPCS-RS35-FB1 {208V} MPPT and 800 V limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sampled CEC PV modules aligned within 400.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 10 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 12 to 18 panels 7.92 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 12 to 17 panels 7.22 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 14 to 19 panels 3.8 kW

Which Competing Grid-Support Inverters Compare to Trystar LLC: OZPCS-RS35-FB1 {208V}?

Peer 208 V, 3-phase CEC inverters near 34,332 W AC output such as CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}
CSI Solar Co Ltd
29,878 W -4454 W 208.0 V 680.0 V 96.38%
Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}
Chint Power Systems America
25,000 W -9332 W 208.0 V 850.0 V 96.26%
EcoFlow Inc: EF-PCS-24 {208V 24kW}
EcoFlow Inc
24,291 W -10040 W 208.0 V 480.0 V 96.01%
Chint Power Systems America: SCA50K-T-US-208 {208V}
Chint Power Systems America
50,000 W +15668 W 208.0 V 700.0 V 95.93%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Trystar LLC: OZPCS-RS35-FB1 {208V}?

Check Trystar LLC: OZPCS-RS35-FB1 {208V} (34,332 W AC, 125 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on Trystar LLC: OZPCS-RS35-FB1 {208V}.

Trystar LLC: OZPCS-RS35-FB1 {208V} Panel & Wire Spec

Size 75 C copper conductors at 1 AWG Cu on a 125 A OCPD breaker (95.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.2%) and MPPT window (400-800 V) directly against CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} (29,878 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Trystar LLC: OZPCS-RS35-FB1 {208V} by Trystar LLC covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.

What breaker and wire size does Trystar LLC: OZPCS-RS35-FB1 {208V} require?

At 34,332 W continuous AC (208 V, 3-phase), continuous current is 95.3 A; 125% NEC 690.8/705.12 sizing requires a 125 A breaker and 1 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Trystar LLC: OZPCS-RS35-FB1 {208V} require?

At 34,332 W AC and 208 V, 3-phase, continuous line current is 95.3 A, requiring a 125 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Trystar LLC: OZPCS-RS35-FB1 {208V} compare to CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V}?

Trystar LLC: OZPCS-RS35-FB1 {208V} delivers 34,332 W AC at 95.2% CEC efficiency with a 800 V DC ceiling, while CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} outputs 29,878 W at 208 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.