Trystar LLC: OZPCS-EP40-000 {208V} outputs 17,230 W AC at 208 V, 3-phase (47.8 A continuous, 60 A OCPD), ranking #2,305 of 2,343 CEC inverters at 94.25% efficiency with a 550-820 V MPPT window and 820 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 17,230 W
- AC Voltage
- 208 V, 3-phase
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 94.25%
How Does Trystar LLC: OZPCS-EP40-000 {208V} Compare Against Peer CEC Listings?
How Trystar LLC Trystar LLC: OZPCS-EP40-000 {208V} compares on 94.25% efficiency, MPPT span, and 120% busbar interconnection. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
With a 550-820 V MPPT tracking band and 820 V DC ceiling, Trystar LLC: OZPCS-EP40-000 {208V} handles 17,230 W continuous AC (12,230 W above the 5,000 W 208 V median). Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Installers comparing Trystar LLC against EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} (13,899 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.
Where Does Trystar LLC: OZPCS-EP40-000 {208V} Fall Across Listed CEC Models?
Position of Trystar LLC: OZPCS-EP40-000 {208V} (17,230 W AC) relative to the 7,680 W CEC median inverter. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Trystar LLC: OZPCS-EP40-000 {208V}?
Percentile placement of Trystar LLC: OZPCS-EP40-000 {208V} across AC power class, conversion efficiency, and backfeed breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for Trystar LLC: OZPCS-EP40-000 {208V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Trystar LLC: OZPCS-EP40-000 {208V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
94.25% CEC Weighted Efficiency
-2.16 pts vs the 96.41% 208 V median; overall power rank #642 (17,230 W, top 27.5%; higher than 72.5% of peers).
60 A Required Backfeed OCPD
125% x 47.8 A = 59.8 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
550 V - 820 V (Max 820 V DC)
Tracking span of 270.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 17229.9W / 208 V 3-phase -> 47.8 A | Breaker >= 1.25 * 47.8 = 59.8 A -> 60 A
CEC Inverters.csv for Trystar LLC: OZPCS-EP40-000 {208V}: Paco=17229.9 W, Vac=208 V, Vdcmax=820.0 V, Eff=94.25%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Trystar LLC: OZPCS-EP40-000 {208V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Trystar LLC: OZPCS-EP40-000 {208V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 17,230 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 820 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 550 V - 820 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 26.1152 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 94.25% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to Trystar LLC: OZPCS-EP40-000 {208V} (208 V, 3-phase)?
Check whether Trystar LLC: OZPCS-EP40-000 {208V} (60 A breaker) fits without main breaker derate or supply-side taps. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 60 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (208V) | 80 A | 60 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 60 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 60 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 60 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Trystar LLC: OZPCS-EP40-000 {208V}?
Verified cold-weather (-10 C) series module counts matched to Trystar LLC: OZPCS-EP40-000 {208V}'s 820 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 13 to 14 panels | 8.26 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 17 to 19 panels | 8.36 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 16 to 18 panels | 7.65 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 20 panels (fixed) | 4.0 kW |
Which Competing Grid-Support Inverters Compare to Trystar LLC: OZPCS-EP40-000 {208V}?
Alternative CEC inverters comparable to Trystar LLC: OZPCS-EP40-000 {208V}, including EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} (13,899 W) at 208 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} EG4 Electronics LLC |
13,899 W | -3331 W | 208.0 V | 440.0 V | 96.46% |
| Chint Power Systems America: CPS ECH12KTL/US {208V} Chint Power Systems America |
12,000 W | -5230 W | 208.0 V | 480.0 V | 96.63% |
| EcoFlow Inc: EF-PCS-24 {208V 115kW} EcoFlow Inc |
11,444 W | -5786 W | 208.0 V | 480.0 V | 96.52% |
| Chint Power Systems America: CPS ECH114KTL/US {208V} Chint Power Systems America |
11,350 W | -5880 W | 208.0 V | 480.0 V | 96.63% |
What Are the Interconnection Limits and Best-Fit Uses for Trystar LLC: OZPCS-EP40-000 {208V}?
Check Trystar LLC: OZPCS-EP40-000 {208V} (17,230 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 820 V DC on Trystar LLC: OZPCS-EP40-000 {208V}.
Trystar LLC: OZPCS-EP40-000 {208V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.8 A continuous).
Alternative Inverter Comparison
Compare efficiency (94.25%) and MPPT window (550-820 V) directly against EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} (13,899 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Trystar LLC: OZPCS-EP40-000 {208V} by Trystar LLC covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.
What breaker and wire size does Trystar LLC: OZPCS-EP40-000 {208V} require?
At 17,230 W continuous AC (208 V, 3-phase), continuous current is 47.8 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Trystar LLC: OZPCS-EP40-000 {208V} require?
At 17,230 W AC and 208 V, 3-phase, continuous line current is 47.8 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Trystar LLC: OZPCS-EP40-000 {208V} compare to EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}?
Trystar LLC: OZPCS-EP40-000 {208V} delivers 17,230 W AC at 94.25% CEC efficiency with a 820 V DC ceiling, while EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} outputs 13,899 W at 208 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)