SolarEdge Technologies Ltd: SE11400A-US {240V} outputs 11,390 W AC at 240 V (47.5 A continuous, 60 A OCPD), ranking #684 of 2,343 CEC inverters at 97.3% efficiency with a 360-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 11,390 W
- AC Voltage
- 240 V
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 97.3%
How Does SolarEdge Technologies Ltd: SE11400A-US {240V} Compare Against Peer CEC Listings?
Breaker sizing (60 A), 6 AWG Cu wire rules, and DC input limits for SolarEdge Technologies Ltd: SE11400A-US {240V}.
For NEC 705.12 solar interconnection, SolarEdge Technologies Ltd: SE11400A-US {240V} outputs 47.5 A continuous AC at 240 V and needs a 60 A backfeed breaker on 6 AWG Cu (75 C). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Conversion efficiency scores 97.3% (#684 of 2,343, +0.48 pts vs overall CEC median).
Where Does SolarEdge Technologies Ltd: SE11400A-US {240V} Fall Across Listed CEC Models?
Output power comparison showing where SolarEdge Technologies Ltd: SE11400A-US {240V} sits among all 2,343 CEC-listed grid-support inverters. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Dataset Percentiles Define SolarEdge Technologies Ltd: SE11400A-US {240V}?
Relative ranking of SolarEdge Technologies Ltd: SE11400A-US {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for SolarEdge Technologies Ltd: SE11400A-US {240V}?
Snapshot of SolarEdge Technologies Ltd: SE11400A-US {240V} efficiency rank (#684), OCPD breaker size, MPPT span, and busbar verdict.
97.3% CEC Weighted Efficiency
+0.62 pts vs the 96.68% 240 V median; overall power rank #789 (11,390 W, top 33.7%; higher than 66.3% of peers).
60 A Required Backfeed OCPD
125% x 47.5 A = 59.4 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
360 V - 480 V (Max 480 V DC)
Tracking span of 120.0 V; listed since 2018-10-15 (grid-tied PV inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 11390.0W / 240 V -> 47.5 A | Breaker >= 1.25 * 47.5 = 59.4 A -> 60 A
CEC Inverters.csv for SolarEdge Technologies Ltd: SE11400A-US {240V}: Paco=11390.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.3%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for SolarEdge Technologies Ltd: SE11400A-US {240V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SolarEdge Technologies Ltd: SE11400A-US {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 11,390 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 360 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 29.2664 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.3% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2018-10-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for SolarEdge Technologies Ltd: SE11400A-US {240V}?
NEC 705.12(B)(3)(2) backfeed compliance table for SolarEdge Technologies Ltd: SE11400A-US {240V} at 240 V. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 60 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 60 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 60 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With SolarEdge Technologies Ltd: SE11400A-US {240V}?
Minimum and maximum series solar module strings fitting SolarEdge Technologies Ltd: SE11400A-US {240V} MPPT and 480 V limits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 11 panels (fixed) | 4.84 kW |
Which Competing Grid-Support Inverters Compare to SolarEdge Technologies Ltd: SE11400A-US {240V}?
Peer 240 V CEC inverters near 11,390 W AC output such as Altenergy Power System Inc: ELS-114 {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Altenergy Power System Inc: ELS-114 {240V} Altenergy Power System Inc |
11,415 W | +25 W | 240.0 V | 60.0 V | 93.08% |
| Chint Power Systems America: CPS ECH114KTL/US {240V} Chint Power Systems America |
11,360 W | -30 W | 240.0 V | 480.0 V | 96.53% |
| Dyness Digital Energy Technology Co LTD: TX114K-HM {240V} Dyness Digital Energy Technology Co LTD |
11,498 W | +108 W | 240.0 V | 500.0 V | 96.41% |
| Dyness Digital Energy Technology Co LTD: TX114K-AM {240V} Dyness Digital Energy Technology Co LTD |
11,519 W | +129 W | 240.0 V | 490.0 V | 96.21% |
What Are the Interconnection Limits and Best-Fit Uses for SolarEdge Technologies Ltd: SE11400A-US {240V}?
Check SolarEdge Technologies Ltd: SE11400A-US {240V} (11,390 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on SolarEdge Technologies Ltd: SE11400A-US {240V}.
SolarEdge Technologies Ltd: SE11400A-US {240V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.5 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.3%) and MPPT window (360-480 V) directly against Altenergy Power System Inc: ELS-114 {240V} (11,415 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SolarEdge Technologies Ltd: SE11400A-US {240V} by SolarEdge Technologies Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does SolarEdge Technologies Ltd: SE11400A-US {240V} require?
At 11,390 W continuous AC (240 V), continuous current is 47.5 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
Does SolarEdge Technologies Ltd: SE11400A-US {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.
How does SolarEdge Technologies Ltd: SE11400A-US {240V} compare to Altenergy Power System Inc: ELS-114 {240V}?
SolarEdge Technologies Ltd: SE11400A-US {240V} delivers 11,390 W AC at 97.3% CEC efficiency with a 480 V DC ceiling, while Altenergy Power System Inc: ELS-114 {240V} outputs 11,415 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)