SolarEdge Technologies Ltd: SE11400A-US {240V} — CEC Inverter Specifications

Manufacturer: SolarEdge Technologies Ltd Registry: CEC Verified Engineering Specification

SolarEdge Technologies Ltd: SE11400A-US {240V} outputs 11,390 W AC at 240 V (47.5 A continuous, 60 A OCPD), ranking #684 of 2,343 CEC inverters at 97.3% efficiency with a 360-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
11,390 W
AC Voltage
240 V
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
97.3%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SolarEdge Technologies Ltd: SE11400A-US {240V} Compare Against Peer CEC Listings?

Breaker sizing (60 A), 6 AWG Cu wire rules, and DC input limits for SolarEdge Technologies Ltd: SE11400A-US {240V}.

For NEC 705.12 solar interconnection, SolarEdge Technologies Ltd: SE11400A-US {240V} outputs 47.5 A continuous AC at 240 V and needs a 60 A backfeed breaker on 6 AWG Cu (75 C). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Conversion efficiency scores 97.3% (#684 of 2,343, +0.48 pts vs overall CEC median).

Where Does SolarEdge Technologies Ltd: SE11400A-US {240V} Fall Across Listed CEC Models?

Output power comparison showing where SolarEdge Technologies Ltd: SE11400A-US {240V} sits among all 2,343 CEC-listed grid-support inverters. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SolarEdge Technologies Ltd: SE11400A-US {240V} (11,390 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolarEdge Technolo: 11,390 W

What Dataset Percentiles Define SolarEdge Technologies Ltd: SE11400A-US {240V}?

Relative ranking of SolarEdge Technologies Ltd: SE11400A-US {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

SolarEdge Technologies Ltd: SE11400A-US {240V} Technical ThresholdsPercentile comparison for SolarEdge Technologies Ltd: SE11400A-US {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output11,390 WCEC Efficiency97.3%Backfeed Breaker60 A

What Do the Dataset Ranks Show for SolarEdge Technologies Ltd: SE11400A-US {240V}?

Snapshot of SolarEdge Technologies Ltd: SE11400A-US {240V} efficiency rank (#684), OCPD breaker size, MPPT span, and busbar verdict.

Eff #684 / 2,343

97.3% CEC Weighted Efficiency

+0.62 pts vs the 96.68% 240 V median; overall power rank #789 (11,390 W, top 33.7%; higher than 66.3% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 47.5 A = 59.4 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

360 V - 480 V (Max 480 V DC)

Tracking span of 120.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11390.0W / 240 V -> 47.5 A | Breaker >= 1.25 * 47.5 = 59.4 A -> 60 A

CEC Inverters.csv for SolarEdge Technologies Ltd: SE11400A-US {240V}: Paco=11390.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.3%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for SolarEdge Technologies Ltd: SE11400A-US {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SolarEdge Technologies Ltd: SE11400A-US {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for SolarEdge Technologies Ltd: SE11400A-US {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 11,390 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 360 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 29.2664 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.3% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for SolarEdge Technologies Ltd: SE11400A-US {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for SolarEdge Technologies Ltd: SE11400A-US {240V} at 240 V. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Evaluates SolarEdge Technologies Ltd: SE11400A-US {240V} (60 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 60 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 60 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 60 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 60 A PASS (120% Rule)
225A Bus / 200A Main 70 A 60 A PASS (120% Rule)

Which CEC PV Module Strings Pair With SolarEdge Technologies Ltd: SE11400A-US {240V}?

Minimum and maximum series solar module strings fitting SolarEdge Technologies Ltd: SE11400A-US {240V} MPPT and 480 V limits.

Sampled CEC PV modules aligned within 360.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 11 panels (fixed) 4.84 kW

Which Competing Grid-Support Inverters Compare to SolarEdge Technologies Ltd: SE11400A-US {240V}?

Peer 240 V CEC inverters near 11,390 W AC output such as Altenergy Power System Inc: ELS-114 {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Altenergy Power System Inc: ELS-114 {240V}
Altenergy Power System Inc
11,415 W +25 W 240.0 V 60.0 V 93.08%
Chint Power Systems America: CPS ECH114KTL/US {240V}
Chint Power Systems America
11,360 W -30 W 240.0 V 480.0 V 96.53%
Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}
Dyness Digital Energy Technology Co LTD
11,498 W +108 W 240.0 V 500.0 V 96.41%
Dyness Digital Energy Technology Co LTD: TX114K-AM {240V}
Dyness Digital Energy Technology Co LTD
11,519 W +129 W 240.0 V 490.0 V 96.21%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SolarEdge Technologies Ltd: SE11400A-US {240V}?

Check SolarEdge Technologies Ltd: SE11400A-US {240V} (11,390 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on SolarEdge Technologies Ltd: SE11400A-US {240V}.

SolarEdge Technologies Ltd: SE11400A-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.3%) and MPPT window (360-480 V) directly against Altenergy Power System Inc: ELS-114 {240V} (11,415 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SolarEdge Technologies Ltd: SE11400A-US {240V} by SolarEdge Technologies Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does SolarEdge Technologies Ltd: SE11400A-US {240V} require?

At 11,390 W continuous AC (240 V), continuous current is 47.5 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

Does SolarEdge Technologies Ltd: SE11400A-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

How does SolarEdge Technologies Ltd: SE11400A-US {240V} compare to Altenergy Power System Inc: ELS-114 {240V}?

SolarEdge Technologies Ltd: SE11400A-US {240V} delivers 11,390 W AC at 97.3% CEC efficiency with a 480 V DC ceiling, while Altenergy Power System Inc: ELS-114 {240V} outputs 11,415 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.