SolarEdge Technologies Ltd: SE285KUS {600V} outputs 284,159 W AC at 600 V, 3-phase (273.4 A continuous, 400 A OCPD), ranking #48 of 2,343 CEC inverters at 98.61% efficiency with a 1,090-1,320 V MPPT window and 1,320 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 284,159 W
- AC Voltage
- 600 V, 3-phase
- Min PV Breaker
- 400 A (parallel Cu feeders)
- CEC Efficiency
- 98.61%
How Does SolarEdge Technologies Ltd: SE285KUS {600V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 600 V, 3-phase grid-support overview for SolarEdge Technologies Ltd: SE285KUS {600V}.
Ranking #216 of 2,343 CEC inverters (top 9.2%; higher than 90.8% of peers), SolarEdge Technologies Ltd: SE285KUS {600V} is a grid-tied PV inverter delivering 284,159 W continuous AC at 600 V, 3-phase (273.4 A continuous). Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.61% (+0.33 pts vs the 98.28% 600 V median) against peers like Chint Power Systems America: SCH250K-T-US-600 {600V} (250,000 W).
Where Does SolarEdge Technologies Ltd: SE285KUS {600V} Fall Across Listed CEC Models?
Marks SolarEdge Technologies Ltd: SE285KUS {600V} (284,159 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define SolarEdge Technologies Ltd: SE285KUS {600V}?
Benchmarks SolarEdge Technologies Ltd: SE285KUS {600V} continuous AC output, 98.61% CEC weighted efficiency, and 400 A OCPD breaker demand.
What Do the Dataset Ranks Show for SolarEdge Technologies Ltd: SE285KUS {600V}?
Four key NEC 705.12 and California Energy Commission metrics defining SolarEdge Technologies Ltd: SE285KUS {600V} by SolarEdge Technologies Ltd.
98.61% CEC Weighted Efficiency
+0.33 pts vs the 98.28% 600 V median; overall power rank #216 (284,159 W, top 9.2%; higher than 90.8% of peers).
400 A Required Backfeed OCPD
125% x 273.4 A = 341.8 A -> 400 A standard OCPD using parallel Cu feeders (75 C).
1,090 V - 1,320 V (Max 1,320 V DC)
Tracking span of 230.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 284159.0W / 600 V 3-phase -> 273.4 A | Breaker >= 1.25 * 273.4 = 341.8 A -> 400 A
CEC Inverters.csv for SolarEdge Technologies Ltd: SE285KUS {600V}: Paco=284159.0 W, Vac=600 V, Vdcmax=1320.0 V, Eff=98.61%.
Result: Min 400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (600V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for SolarEdge Technologies Ltd: SE285KUS {600V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SolarEdge Technologies Ltd: SE285KUS {600V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 284,159 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 600 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,320 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 1,090 V - 1,320 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 230.53 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.61% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to SolarEdge Technologies Ltd: SE285KUS {600V} (600 V, 3-phase)?
Evaluates SolarEdge Technologies Ltd: SE285KUS {600V} (400 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (600V) | 40 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (600V) | 80 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (600V) | 120 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (600V) | 160 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (600V) | 240 A | 400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which Competing Grid-Support Inverters Compare to SolarEdge Technologies Ltd: SE285KUS {600V}?
Competing CEC grid-support inverters near 284,159 W AC and 600 V, 3-phase, led by Chint Power Systems America: SCH250K-T-US-600 {600V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Chint Power Systems America: SCH250K-T-US-600 {600V} Chint Power Systems America |
250,000 W | -34159 W | 600.0 V | 1300.0 V | 98.21% |
| Yaskawa Solectria Solar: XGI 1500 250/250-600 {600V} Yaskawa Solectria Solar |
250,000 W | -34159 W | 600.0 V | 1250.0 V | 98.11% |
| Yaskawa Solectria Solar: XGI 1500-250/250-600-DCG {600V} Yaskawa Solectria Solar |
250,000 W | -34159 W | 600.0 V | 1250.0 V | 98.19% |
| Ginlong Technologies Co Ltd: S6-GU250K-EHV-US-M12 {600V} Ginlong Technologies Co Ltd |
248,751 W | -35408 W | 600.0 V | 1300.0 V | 98.62% |
What Are the Interconnection Limits and Best-Fit Uses for SolarEdge Technologies Ltd: SE285KUS {600V}?
Check SolarEdge Technologies Ltd: SE285KUS {600V} (284,159 W AC, 400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,320 V DC on SolarEdge Technologies Ltd: SE285KUS {600V}.
SolarEdge Technologies Ltd: SE285KUS {600V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 400 A OCPD breaker (273.4 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.61%) and MPPT window (1,090-1,320 V) directly against Chint Power Systems America: SCH250K-T-US-600 {600V} (250,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SolarEdge Technologies Ltd: SE285KUS {600V} by SolarEdge Technologies Ltd covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.
What breaker and wire size does SolarEdge Technologies Ltd: SE285KUS {600V} require?
At 284,159 W continuous AC (600 V, 3-phase), continuous current is 273.4 A; 125% NEC 690.8/705.12 sizing requires a 400 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does SolarEdge Technologies Ltd: SE285KUS {600V} require?
At 284,159 W AC and 600 V, 3-phase, continuous line current is 273.4 A, requiring a 400 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.
How does SolarEdge Technologies Ltd: SE285KUS {600V} compare to Chint Power Systems America: SCH250K-T-US-600 {600V}?
SolarEdge Technologies Ltd: SE285KUS {600V} delivers 284,159 W AC at 98.61% CEC efficiency with a 1,320 V DC ceiling, while Chint Power Systems America: SCH250K-T-US-600 {600V} outputs 250,000 W at 600 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)