Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SolarEdge Technologies Ltd: SE250KUS {600V} — CEC Inverter Specifications

Manufacturer: SolarEdge Technologies Ltd Registry: CEC Verified Engineering Specification

SolarEdge Technologies Ltd: SE250KUS {600V} outputs 249,907 W AC at 600 V, 3-phase (240.5 A continuous, 400 A OCPD), ranking #31 of 2,343 CEC inverters at 98.7% efficiency with a 1,090-1,320 V MPPT window and 1,320 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
249,907 W
AC Voltage
600 V, 3-phase
Min PV Breaker
400 A (parallel Cu feeders)
CEC Efficiency
98.7%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SolarEdge Technologies Ltd: SE250KUS {600V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 600 V, 3-phase grid-support overview for SolarEdge Technologies Ltd: SE250KUS {600V}.

Ranking #230 of 2,343 CEC inverters (top 9.8%; higher than 90.2% of peers), SolarEdge Technologies Ltd: SE250KUS {600V} is a grid-tied PV inverter delivering 249,907 W continuous AC at 600 V, 3-phase (240.5 A continuous). Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.7% (+0.42 pts vs the 98.28% 600 V median) against peers like Chint Power Systems America: SCH250K-T-US-600 {600V} (250,000 W).

Where Does SolarEdge Technologies Ltd: SE250KUS {600V} Fall Across Listed CEC Models?

Marks SolarEdge Technologies Ltd: SE250KUS {600V} (249,907 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SolarEdge Technologies Ltd: SE250KUS {600V} (249,907 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolarEdge Technolo: 249,907 W

What Dataset Percentiles Define SolarEdge Technologies Ltd: SE250KUS {600V}?

Benchmarks SolarEdge Technologies Ltd: SE250KUS {600V} continuous AC output, 98.7% CEC weighted efficiency, and 400 A OCPD breaker demand.

SolarEdge Technologies Ltd: SE250KUS {600V} Technical ThresholdsPercentile comparison for SolarEdge Technologies Ltd: SE250KUS {600V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output249,907 WCEC Efficiency98.7%Backfeed Breaker400 A

What Do the Dataset Ranks Show for SolarEdge Technologies Ltd: SE250KUS {600V}?

Four key NEC 705.12 and California Energy Commission metrics defining SolarEdge Technologies Ltd: SE250KUS {600V} by SolarEdge Technologies Ltd.

Eff #31 / 2,343

98.7% CEC Weighted Efficiency

+0.42 pts vs the 98.28% 600 V median; overall power rank #230 (249,907 W, top 9.8%; higher than 90.2% of peers).

NEC 705.12 Check

400 A Required Backfeed OCPD

125% x 240.5 A = 300.6 A -> 400 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,090 V - 1,320 V (Max 1,320 V DC)

Tracking span of 230.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 249907.0W / 600 V 3-phase -> 240.5 A | Breaker >= 1.25 * 240.5 = 300.6 A -> 400 A

CEC Inverters.csv for SolarEdge Technologies Ltd: SE250KUS {600V}: Paco=249907.0 W, Vac=600 V, Vdcmax=1320.0 V, Eff=98.7%.

Result: Min 400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (600V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for SolarEdge Technologies Ltd: SE250KUS {600V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SolarEdge Technologies Ltd: SE250KUS {600V}.

Official California Energy Commission (NREL SAM) test parameters for SolarEdge Technologies Ltd: SE250KUS {600V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 249,907 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 600 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,320 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,090 V - 1,320 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 202.558 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.7% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SolarEdge Technologies Ltd: SE250KUS {600V} (600 V, 3-phase)?

Evaluates SolarEdge Technologies Ltd: SE250KUS {600V} (400 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SolarEdge Technologies Ltd: SE250KUS {600V} (400 A required OCPD at 600 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (600V) 40 A 400 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (600V) 80 A 400 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (600V) 120 A 400 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (600V) 160 A 400 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (600V) 240 A 400 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which Competing Grid-Support Inverters Compare to SolarEdge Technologies Ltd: SE250KUS {600V}?

Competing CEC grid-support inverters near 249,907 W AC and 600 V, 3-phase, led by Chint Power Systems America: SCH250K-T-US-600 {600V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: SCH250K-T-US-600 {600V}
Chint Power Systems America
250,000 W +93 W 600.0 V 1300.0 V 98.21%
Yaskawa Solectria Solar: XGI 1500 250/250-600 {600V}
Yaskawa Solectria Solar
250,000 W +93 W 600.0 V 1250.0 V 98.11%
Yaskawa Solectria Solar: XGI 1500-250/250-600-DCG {600V}
Yaskawa Solectria Solar
250,000 W +93 W 600.0 V 1250.0 V 98.19%
Ginlong Technologies Co Ltd: S6-GU250K-EHV-US-M12 {600V}
Ginlong Technologies Co Ltd
248,751 W -1156 W 600.0 V 1300.0 V 98.62%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SolarEdge Technologies Ltd: SE250KUS {600V}?

Check SolarEdge Technologies Ltd: SE250KUS {600V} (249,907 W AC, 400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,320 V DC on SolarEdge Technologies Ltd: SE250KUS {600V}.

SolarEdge Technologies Ltd: SE250KUS {600V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 400 A OCPD breaker (240.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.7%) and MPPT window (1,090-1,320 V) directly against Chint Power Systems America: SCH250K-T-US-600 {600V} (250,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SolarEdge Technologies Ltd: SE250KUS {600V} by SolarEdge Technologies Ltd covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.

What breaker and wire size does SolarEdge Technologies Ltd: SE250KUS {600V} require?

At 249,907 W continuous AC (600 V, 3-phase), continuous current is 240.5 A; 125% NEC 690.8/705.12 sizing requires a 400 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does SolarEdge Technologies Ltd: SE250KUS {600V} require?

At 249,907 W AC and 600 V, 3-phase, continuous line current is 240.5 A, requiring a 400 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.

How does SolarEdge Technologies Ltd: SE250KUS {600V} compare to Chint Power Systems America: SCH250K-T-US-600 {600V}?

SolarEdge Technologies Ltd: SE250KUS {600V} delivers 249,907 W AC at 98.7% CEC efficiency with a 1,320 V DC ceiling, while Chint Power Systems America: SCH250K-T-US-600 {600V} outputs 250,000 W at 600 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.