Chint Power Systems America: CPS ECH114KTL/US {240V} — CEC Inverter Specifications

Manufacturer: Chint Power Systems America Registry: CEC Verified Engineering Specification

Chint Power Systems America: CPS ECH114KTL/US {240V} outputs 11,360 W AC at 240 V (47.3 A continuous, 60 A OCPD), ranking #1,508 of 2,343 CEC inverters at 96.53% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
11,360 W
AC Voltage
240 V
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
96.53%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Chint Power Systems America: CPS ECH114KTL/US {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,508), 200-480 V MPPT tracking, and panel fit for Chint Power Systems America: CPS ECH114KTL/US {240V}.

Operating at 240 V, Chint Power Systems America: CPS ECH114KTL/US {240V} converts DC array energy at 96.53% CEC weighted efficiency (below overall CEC median; higher than 35.2% of peers) with a 480 V max DC input and 31.8059 A max input current for NEC 690.7 string safety. Compare this 11,360 W hybrid battery-capable inverter directly with Altenergy Power System Inc: ELS-114 {240V} (11,415 W). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.

Where Does Chint Power Systems America: CPS ECH114KTL/US {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Chint Power Systems America: CPS ECH114KTL/US {240V} at 11,360 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Chint Power Systems America: CPS ECH114KTL/US {240V} (11,360 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACChint Power System: 11,360 W

What Dataset Percentiles Define Chint Power Systems America: CPS ECH114KTL/US {240V}?

Dataset percentiles comparing Chint Power Systems America: CPS ECH114KTL/US {240V} against 2,343 certified grid-support inverters nationwide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Chint Power Systems America: CPS ECH114KTL/US {240V} Technical ThresholdsPercentile comparison for Chint Power Systems America: CPS ECH114KTL/US {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output11,360 WCEC Efficiency96.53%Backfeed Breaker60 A

What Do the Dataset Ranks Show for Chint Power Systems America: CPS ECH114KTL/US {240V}?

Engineering highlights for Chint Power Systems America: CPS ECH114KTL/US {240V} covering efficiency, 6 AWG Cu feeder, and panel compatibility.

Eff #1,508 / 2,343

96.53% CEC Weighted Efficiency

-0.15 pts vs the 96.68% 240 V median; overall power rank #797 (11,360 W, top 34.0%; higher than 66.0% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 47.3 A = 59.1 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; listed since 2025-04-21 (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11360.0W / 240 V -> 47.3 A | Breaker >= 1.25 * 47.3 = 59.1 A -> 60 A

CEC Inverters.csv for Chint Power Systems America: CPS ECH114KTL/US {240V}: Paco=11360.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.53%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Chint Power Systems America: CPS ECH114KTL/US {240V}?

California Energy Commission Solar Equipment List parameters for Chint Power Systems America: CPS ECH114KTL/US {240V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Chint Power Systems America: CPS ECH114KTL/US {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 11,360 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 31.8059 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.53% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-04-21 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Chint Power Systems America: CPS ECH114KTL/US {240V}?

Panelboard and switchgear backfeed allowances for Chint Power Systems America: CPS ECH114KTL/US {240V} (60 A OCPD). Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Evaluates Chint Power Systems America: CPS ECH114KTL/US {240V} (60 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 60 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 60 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 60 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 60 A PASS (120% Rule)
225A Bus / 200A Main 70 A 60 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Chint Power Systems America: CPS ECH114KTL/US {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Chint Power Systems America: CPS ECH114KTL/US {240V}.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Chint Power Systems America: CPS ECH114KTL/US {240V}?

Four alternative CEC inverters matched to Chint Power Systems America: CPS ECH114KTL/US {240V} (11,360 W AC), led by Altenergy Power System Inc: ELS-114 {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Altenergy Power System Inc: ELS-114 {240V}
Altenergy Power System Inc
11,415 W +55 W 240.0 V 60.0 V 93.08%
Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}
Dyness Digital Energy Technology Co LTD
11,498 W +138 W 240.0 V 500.0 V 96.41%
Dyness Digital Energy Technology Co LTD: TX114K-AM {240V}
Dyness Digital Energy Technology Co LTD
11,519 W +159 W 240.0 V 490.0 V 96.21%
Base Power Inc: MIN 11400TL-XH-US {240V}
Base Power Inc
11,520 W +160 W 240.0 V 480.0 V 97.76%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Chint Power Systems America: CPS ECH114KTL/US {240V}?

Check Chint Power Systems America: CPS ECH114KTL/US {240V} (11,360 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Chint Power Systems America: CPS ECH114KTL/US {240V}.

Chint Power Systems America: CPS ECH114KTL/US {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.53%) and MPPT window (200-480 V) directly against Altenergy Power System Inc: ELS-114 {240V} (11,415 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Chint Power Systems America: CPS ECH114KTL/US {240V} by Chint Power Systems America covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Chint Power Systems America: CPS ECH114KTL/US {240V} require?

At 11,360 W continuous AC (240 V), continuous current is 47.3 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

Does Chint Power Systems America: CPS ECH114KTL/US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

How does Chint Power Systems America: CPS ECH114KTL/US {240V} compare to Altenergy Power System Inc: ELS-114 {240V}?

Chint Power Systems America: CPS ECH114KTL/US {240V} delivers 11,360 W AC at 96.53% CEC efficiency with a 480 V DC ceiling, while Altenergy Power System Inc: ELS-114 {240V} outputs 11,415 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.