SMA America: SI27-US208-20 {208V} outputs 27,176 W AC at 208 V, 3-phase (75.4 A continuous, 100 A OCPD), ranking #2,241 of 2,343 CEC inverters at 95.14% efficiency with a 200-980 V MPPT window and 980 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 27,176 W
- AC Voltage
- 208 V, 3-phase
- Min PV Breaker
- 100 A (3 AWG Cu)
- CEC Efficiency
- 95.14%
How Does SMA America: SI27-US208-20 {208V} Compare Against Peer CEC Listings?
How SMA America SMA America: SI27-US208-20 {208V} compares on 95.14% efficiency, MPPT span, and 120% busbar interconnection. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
With a 200-980 V MPPT tracking band and 980 V DC ceiling, SMA America: SI27-US208-20 {208V} handles 27,176 W continuous AC (22,176 W above the 5,000 W 208 V median). Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Installers comparing SMA America against Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V} (25,000 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.
Where Does SMA America: SI27-US208-20 {208V} Fall Across Listed CEC Models?
Position of SMA America: SI27-US208-20 {208V} (27,176 W AC) relative to the 7,680 W CEC median inverter. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define SMA America: SI27-US208-20 {208V}?
Percentile placement of SMA America: SI27-US208-20 {208V} across AC power class, conversion efficiency, and backfeed breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Do the Dataset Ranks Show for SMA America: SI27-US208-20 {208V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for SMA America: SI27-US208-20 {208V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
95.14% CEC Weighted Efficiency
-1.27 pts vs the 96.41% 208 V median; overall power rank #586 (27,176 W, top 25.0%; higher than 75.0% of peers).
100 A Required Backfeed OCPD
125% x 75.4 A = 94.2 A -> 100 A standard OCPD using 3 AWG Cu (75 C).
200 V - 980 V (Max 980 V DC)
Tracking span of 780.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 27175.9W / 208 V 3-phase -> 75.4 A | Breaker >= 1.25 * 75.4 = 94.2 A -> 100 A
CEC Inverters.csv for SMA America: SI27-US208-20 {208V}: Paco=27175.9 W, Vac=208 V, Vdcmax=980.0 V, Eff=95.14%.
Result: Min 100 A breaker & 3 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for SMA America: SI27-US208-20 {208V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for SMA America: SI27-US208-20 {208V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 27,176 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 980 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 200 V - 980 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 36.8583 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 95.14% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to SMA America: SI27-US208-20 {208V} (208 V, 3-phase)?
Check whether SMA America: SI27-US208-20 {208V} (100 A breaker) fits without main breaker derate or supply-side taps. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 100 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (208V) | 80 A | 100 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (208V) | 120 A | 100 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 100 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 100 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With SMA America: SI27-US208-20 {208V}?
Verified cold-weather (-10 C) series module counts matched to SMA America: SI27-US208-20 {208V}'s 980 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 5 to 17 panels | 10.03 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 6 to 23 panels | 10.12 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 6 to 21 panels | 8.93 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 7 to 24 panels | 4.8 kW |
Which Competing Grid-Support Inverters Compare to SMA America: SI27-US208-20 {208V}?
Alternative CEC inverters comparable to SMA America: SI27-US208-20 {208V}, including Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V} (25,000 W) at 208 V, 3-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V} Chint Power Systems America |
25,000 W | -2176 W | 208.0 V | 850.0 V | 96.26% |
| CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V} CSI Solar Co Ltd |
29,878 W | +2702 W | 208.0 V | 680.0 V | 96.38% |
| EcoFlow Inc: EF-PCS-24 {208V 24kW} EcoFlow Inc |
24,291 W | -2884 W | 208.0 V | 480.0 V | 96.01% |
| EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} EG4 Electronics LLC |
13,899 W | -13277 W | 208.0 V | 440.0 V | 96.46% |
What Are the Interconnection Limits and Best-Fit Uses for SMA America: SI27-US208-20 {208V}?
Check SMA America: SI27-US208-20 {208V} (27,176 W AC, 100 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 980 V DC on SMA America: SI27-US208-20 {208V}.
SMA America: SI27-US208-20 {208V} Panel & Wire Spec
Size 75 C copper conductors at 3 AWG Cu on a 100 A OCPD breaker (75.4 A continuous).
Alternative Inverter Comparison
Compare efficiency (95.14%) and MPPT window (200-980 V) directly against Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V} (25,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SMA America: SI27-US208-20 {208V} by SMA America covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.
What breaker and wire size does SMA America: SI27-US208-20 {208V} require?
At 27,176 W continuous AC (208 V, 3-phase), continuous current is 75.4 A; 125% NEC 690.8/705.12 sizing requires a 100 A breaker and 3 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does SMA America: SI27-US208-20 {208V} require?
At 27,176 W AC and 208 V, 3-phase, continuous line current is 75.4 A, requiring a 100 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does SMA America: SI27-US208-20 {208V} compare to Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V}?
SMA America: SI27-US208-20 {208V} delivers 27,176 W AC at 95.14% CEC efficiency with a 980 V DC ceiling, while Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V} outputs 25,000 W at 208 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)