Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: SHP FLEX-US-21 {630V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SHP FLEX-US-21 {630V} outputs 165,662 W AC at 630 V, 3-phase (151.8 A continuous, 200 A OCPD), ranking #64 of 2,343 CEC inverters at 98.56% efficiency with a 925-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
165,662 W
AC Voltage
630 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
98.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SHP FLEX-US-21 {630V} Compare Against Peer CEC Listings?

How SMA America SMA America: SHP FLEX-US-21 {630V} compares on 98.56% efficiency, MPPT span, and 120% busbar interconnection.

With a 925-1,200 V MPPT tracking band and 1,200 V DC ceiling, SMA America: SHP FLEX-US-21 {630V} handles 165,662 W continuous AC (3,034,908 W below the 3,200,570 W 630 V median). Commercial 630 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (630V) or NEC 705.11 supply-side tap. Installers comparing SMA America against EPC Power Corp: 50-200100 {630V} (491,262 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

Where Does SMA America: SHP FLEX-US-21 {630V} Fall Across Listed CEC Models?

Position of SMA America: SHP FLEX-US-21 {630V} (165,662 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SHP FLEX-US-21 {630V} (165,662 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SHP F: 165,662 W

What Dataset Percentiles Define SMA America: SHP FLEX-US-21 {630V}?

Percentile placement of SMA America: SHP FLEX-US-21 {630V} across AC power class, conversion efficiency, and backfeed breaker size.

SMA America: SHP FLEX-US-21 {630V} Technical ThresholdsPercentile comparison for SMA America: SHP FLEX-US-21 {630V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output165,662 WCEC Efficiency98.56%Backfeed Breaker200 A

What Do the Dataset Ranks Show for SMA America: SHP FLEX-US-21 {630V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for SMA America: SHP FLEX-US-21 {630V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Eff #64 / 2,343

98.56% CEC Weighted Efficiency

+0.62 pts vs the 97.94% 630 V median; overall power rank #267 (165,662 W, top 11.4%; higher than 88.6% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 151.8 A = 189.8 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

925 V - 1,200 V (Max 1,200 V DC)

Tracking span of 275.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 630 V, 3-phase switchgear (200A Bus / 200A Main (630V) to 1,200A Bus / 1,200A Main (630V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 165662.0W / 630 V 3-phase -> 151.8 A | Breaker >= 1.25 * 151.8 = 189.8 A -> 200 A

CEC Inverters.csv for SMA America: SHP FLEX-US-21 {630V}: Paco=165662.0 W, Vac=630 V, Vdcmax=1200.0 V, Eff=98.56%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (630V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: SHP FLEX-US-21 {630V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for SMA America: SHP FLEX-US-21 {630V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP FLEX-US-21 {630V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 165,662 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 630 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 925 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 169.092 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.56% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SMA America: SHP FLEX-US-21 {630V} (630 V, 3-phase)?

Check whether SMA America: SHP FLEX-US-21 {630V} (200 A breaker) fits without main breaker derate or supply-side taps.

Evaluates SMA America: SHP FLEX-US-21 {630V} (200 A required OCPD at 630 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (630V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (630V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (630V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (630V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (630V) 240 A 200 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SMA America: SHP FLEX-US-21 {630V}?

Verified cold-weather (-10 C) series module counts matched to SMA America: SHP FLEX-US-21 {630V}'s 1,200 V DC ceiling.

Sampled CEC PV modules aligned within 925.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 28 panels (fixed) 12.32 kW

Which Competing Grid-Support Inverters Compare to SMA America: SHP FLEX-US-21 {630V}?

Alternative CEC inverters comparable to SMA America: SHP FLEX-US-21 {630V}, including EPC Power Corp: 50-200100 {630V} (491,262 W) at 630 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EPC Power Corp: 50-200100 {630V}
EPC Power Corp
491,262 W +325600 W 630.0 V 1500.0 V 98.39%
TMEIC: PVU-L0840GR {630V}
TMEIC
794,693 W +629031 W 630.0 V 1200.0 V 98.34%
TMEIC Corporation: PVU-L0840URN {630V}
TMEIC Corporation
796,468 W +630806 W 630.0 V 1200.0 V 98.51%
Sungrow Power Supply Co Ltd: SC1575UD-US {630V}
Sungrow Power Supply Co Ltd
1,582,996 W +1417334 W 630.0 V 1500.0 V 98.28%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP FLEX-US-21 {630V}?

Check SMA America: SHP FLEX-US-21 {630V} (165,662 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 630 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (630V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SHP FLEX-US-21 {630V}.

SMA America: SHP FLEX-US-21 {630V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (151.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.56%) and MPPT window (925-1,200 V) directly against EPC Power Corp: 50-200100 {630V} (491,262 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP FLEX-US-21 {630V} by SMA America covering breaker sizing, MPPT limits, and 630 V, 3-phase interconnection.

What breaker and wire size does SMA America: SHP FLEX-US-21 {630V} require?

At 165,662 W continuous AC (630 V, 3-phase), continuous current is 151.8 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SHP FLEX-US-21 {630V} require?

At 165,662 W AC and 630 V, 3-phase, continuous line current is 151.8 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (630V) or NEC 705.11 interconnection.

How does SMA America: SHP FLEX-US-21 {630V} compare to EPC Power Corp: 50-200100 {630V}?

SMA America: SHP FLEX-US-21 {630V} delivers 165,662 W AC at 98.56% CEC efficiency with a 1,200 V DC ceiling, while EPC Power Corp: 50-200100 {630V} outputs 491,262 W at 630 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.