Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: SHP FLEX-US-21 {400V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SHP FLEX-US-21 {400V} outputs 105,632 W AC at 400 V, 3-phase (152.5 A continuous, 200 A OCPD), ranking #376 of 2,343 CEC inverters at 97.92% efficiency with a 590-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
105,632 W
AC Voltage
400 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
97.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SHP FLEX-US-21 {400V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 400 V, 3-phase grid-support overview for SMA America: SHP FLEX-US-21 {400V}.

Ranking #328 of 2,343 CEC inverters (top 14.0%; higher than 86.0% of peers), SMA America: SHP FLEX-US-21 {400V} is a grid-tied PV inverter delivering 105,632 W continuous AC at 400 V, 3-phase (152.5 A continuous). Commercial 400 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (400V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 97.92% (+1.11 pts vs the 96.81% 400 V median) against peers like Yaskawa Solectria Solar: PVI-100TL-480 {480V} (100,000 W).

Where Does SMA America: SHP FLEX-US-21 {400V} Fall Across Listed CEC Models?

Marks SMA America: SHP FLEX-US-21 {400V} (105,632 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SHP FLEX-US-21 {400V} (105,632 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SHP F: 105,632 W

What Dataset Percentiles Define SMA America: SHP FLEX-US-21 {400V}?

Benchmarks SMA America: SHP FLEX-US-21 {400V} continuous AC output, 97.92% CEC weighted efficiency, and 200 A OCPD breaker demand.

SMA America: SHP FLEX-US-21 {400V} Technical ThresholdsPercentile comparison for SMA America: SHP FLEX-US-21 {400V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output105,632 WCEC Efficiency97.92%Backfeed Breaker200 A

What Do the Dataset Ranks Show for SMA America: SHP FLEX-US-21 {400V}?

Four key NEC 705.12 and California Energy Commission metrics defining SMA America: SHP FLEX-US-21 {400V} by SMA America.

Eff #376 / 2,343

97.92% CEC Weighted Efficiency

+1.11 pts vs the 96.81% 400 V median; overall power rank #328 (105,632 W, top 14.0%; higher than 86.0% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 152.5 A = 190.6 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

590 V - 1,200 V (Max 1,200 V DC)

Tracking span of 610.0 V; listed since 2025-01-02 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 400 V, 3-phase switchgear (200A Bus / 200A Main (400V) to 1,200A Bus / 1,200A Main (400V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 105632.0W / 400 V 3-phase -> 152.5 A | Breaker >= 1.25 * 152.5 = 190.6 A -> 200 A

CEC Inverters.csv for SMA America: SHP FLEX-US-21 {400V}: Paco=105632.0 W, Vac=400 V, Vdcmax=1200.0 V, Eff=97.92%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (400V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: SHP FLEX-US-21 {400V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SMA America: SHP FLEX-US-21 {400V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP FLEX-US-21 {400V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 105,632 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 400 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 590 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 134.84 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.92% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-01-02 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to SMA America: SHP FLEX-US-21 {400V} (400 V, 3-phase)?

Evaluates SMA America: SHP FLEX-US-21 {400V} (200 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SMA America: SHP FLEX-US-21 {400V} (200 A required OCPD at 400 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (400V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (400V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (400V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (400V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (400V) 240 A 200 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SMA America: SHP FLEX-US-21 {400V}?

Sample PV string lengths aligned within 590-1,200 V MPPT and 1,200 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 590.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 14 to 21 panels 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 18 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 18 to 26 panels 11.05 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 21 to 29 panels 5.8 kW

Which Competing Grid-Support Inverters Compare to SMA America: SHP FLEX-US-21 {400V}?

Competing CEC grid-support inverters near 105,632 W AC and 400 V, 3-phase, led by Yaskawa Solectria Solar: PVI-100TL-480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Yaskawa Solectria Solar: PVI-100TL-480 {480V}
Yaskawa Solectria Solar
100,000 W -5632 W 480.0 V 850.0 V 98.06%
Ginlong Technologies Co Ltd: S5-GC90K-US {480V}
Ginlong Technologies Co Ltd
89,449 W -16183 W 480.0 V 850.0 V 97.99%
JingTsing Technology Ltd: JTES-PCS125K-1000/480-L03C1 {480V}
JingTsing Technology Ltd
127,819 W +22187 W 480.0 V 950.0 V 98.0%
Shenzhen Growatt New Energy Co Ltd: WIT 75K-HU-US {480V}
Shenzhen Growatt New Energy Co Ltd
74,589 W -31043 W 480.0 V 800.0 V 96.76%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP FLEX-US-21 {400V}?

Check SMA America: SHP FLEX-US-21 {400V} (105,632 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 400 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (400V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SHP FLEX-US-21 {400V}.

SMA America: SHP FLEX-US-21 {400V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (152.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.92%) and MPPT window (590-1,200 V) directly against Yaskawa Solectria Solar: PVI-100TL-480 {480V} (100,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP FLEX-US-21 {400V} by SMA America covering breaker sizing, MPPT limits, and 400 V, 3-phase interconnection.

What breaker and wire size does SMA America: SHP FLEX-US-21 {400V} require?

At 105,632 W continuous AC (400 V, 3-phase), continuous current is 152.5 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SHP FLEX-US-21 {400V} require?

At 105,632 W AC and 400 V, 3-phase, continuous line current is 152.5 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (400V) or NEC 705.11 interconnection.

How does SMA America: SHP FLEX-US-21 {400V} compare to Yaskawa Solectria Solar: PVI-100TL-480 {480V}?

SMA America: SHP FLEX-US-21 {400V} delivers 105,632 W AC at 97.92% CEC efficiency with a 1,200 V DC ceiling, while Yaskawa Solectria Solar: PVI-100TL-480 {480V} outputs 100,000 W at 400 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.