Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SHP FLEX-US-21 {385V} outputs 100,842 W AC at 385 V, 3-phase (151.2 A continuous, 200 A OCPD), ranking #422 of 2,343 CEC inverters at 97.8% efficiency with a 582-1,195 V MPPT window and 1,195 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
100,842 W
AC Voltage
385 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
97.8%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SHP FLEX-US-21 {385V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 385 V, 3-phase grid-support overview for SMA America: SHP FLEX-US-21 {385V}.

Rated at 100,842 W AC (151.2 A continuous), SMA America: SHP FLEX-US-21 {385V} ranks #422 of 2,343 CEC units at 97.8% efficiency (+0.96 pts vs the 96.84% 385 V median). Minimum 75 C copper conductor sizing for its 200 A circuit is 3/0 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 1,195 V DC at record local winter lows.

Where Does SMA America: SHP FLEX-US-21 {385V} Fall Across Listed CEC Models?

Marks SMA America: SHP FLEX-US-21 {385V} (100,842 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SHP FLEX-US-21 {385V} (100,842 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SHP F: 100,842 W

What Dataset Percentiles Define SMA America: SHP FLEX-US-21 {385V}?

Benchmarks SMA America: SHP FLEX-US-21 {385V} continuous AC output, 97.8% CEC weighted efficiency, and 200 A OCPD breaker demand.

SMA America: SHP FLEX-US-21 {385V} Technical ThresholdsPercentile comparison for SMA America: SHP FLEX-US-21 {385V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output100,842 WCEC Efficiency97.8%Backfeed Breaker200 A

What Do the Dataset Ranks Show for SMA America: SHP FLEX-US-21 {385V}?

Four key NEC 705.12 and California Energy Commission metrics defining SMA America: SHP FLEX-US-21 {385V} by SMA America.

Eff #422 / 2,343

97.8% CEC Weighted Efficiency

+0.96 pts vs the 96.84% 385 V median; overall power rank #329 (100,842 W, top 14.1%; higher than 85.9% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 151.2 A = 189.0 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

582 V - 1,195 V (Max 1,195 V DC)

Tracking span of 613.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 385 V, 3-phase switchgear (200A Bus / 200A Main (385V) to 1,200A Bus / 1,200A Main (385V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 100842.0W / 385 V 3-phase -> 151.2 A | Breaker >= 1.25 * 151.2 = 189.0 A -> 200 A

CEC Inverters.csv for SMA America: SHP FLEX-US-21 {385V}: Paco=100842.0 W, Vac=385 V, Vdcmax=1195.0 V, Eff=97.8%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (385V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: SHP FLEX-US-21 {385V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SMA America: SHP FLEX-US-21 {385V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP FLEX-US-21 {385V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 100,842 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 385 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,195 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 582 V - 1,195 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 138.403 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.8% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SMA America: SHP FLEX-US-21 {385V} (385 V, 3-phase)?

Evaluates SMA America: SHP FLEX-US-21 {385V} (200 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SMA America: SHP FLEX-US-21 {385V} (200 A required OCPD at 385 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (385V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (385V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (385V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (385V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (385V) 240 A 200 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SMA America: SHP FLEX-US-21 {385V}?

Sample PV string lengths aligned within 582-1,195 V MPPT and 1,195 V DC max at -10 C. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sampled CEC PV modules aligned within 582.0-1195.0 V MPPT and 1195.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 14 to 21 panels 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 18 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 17 to 26 panels 11.05 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 21 to 29 panels 5.8 kW

Which Competing Grid-Support Inverters Compare to SMA America: SHP FLEX-US-21 {385V}?

Competing CEC grid-support inverters near 100,842 W AC and 385 V, 3-phase, led by Yaskawa Solectria Solar: PVI-100TL-480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Yaskawa Solectria Solar: PVI-100TL-480 {480V}
Yaskawa Solectria Solar
100,000 W -842 W 480.0 V 850.0 V 98.06%
Ginlong Technologies Co Ltd: S5-GC90K-US {480V}
Ginlong Technologies Co Ltd
89,449 W -11393 W 480.0 V 850.0 V 97.99%
Shenzhen Growatt New Energy Co Ltd: WIT 75K-HU-US {480V}
Shenzhen Growatt New Energy Co Ltd
74,589 W -26253 W 480.0 V 800.0 V 96.76%
CSI Solar Co Ltd: CSI-75K-T480GL03-U {480V}
CSI Solar Co Ltd
74,574 W -26268 W 480.0 V 850.0 V 98.17%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP FLEX-US-21 {385V}?

Check SMA America: SHP FLEX-US-21 {385V} (100,842 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 385 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (385V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,195 V DC on SMA America: SHP FLEX-US-21 {385V}.

SMA America: SHP FLEX-US-21 {385V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (151.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.8%) and MPPT window (582-1,195 V) directly against Yaskawa Solectria Solar: PVI-100TL-480 {480V} (100,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP FLEX-US-21 {385V} by SMA America covering breaker sizing, MPPT limits, and 385 V, 3-phase interconnection.

What breaker and wire size does SMA America: SHP FLEX-US-21 {385V} require?

At 100,842 W continuous AC (385 V, 3-phase), continuous current is 151.2 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SHP FLEX-US-21 {385V} require?

At 100,842 W AC and 385 V, 3-phase, continuous line current is 151.2 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (385V) or NEC 705.11 interconnection.

How does SMA America: SHP FLEX-US-21 {385V} compare to Yaskawa Solectria Solar: PVI-100TL-480 {480V}?

SMA America: SHP FLEX-US-21 {385V} delivers 100,842 W AC at 97.8% CEC efficiency with a 1,195 V DC ceiling, while Yaskawa Solectria Solar: PVI-100TL-480 {480V} outputs 100,000 W at 385 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.