Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SHP FLEX-US-21 {320V} outputs 84,904 W AC at 320 V, 3-phase (153.2 A continuous, 200 A OCPD), ranking #543 of 2,343 CEC inverters at 97.52% efficiency with a 495-1,195 V MPPT window and 1,195 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
84,904 W
AC Voltage
320 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
97.52%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SHP FLEX-US-21 {320V} Compare Against Peer CEC Listings?

How SMA America SMA America: SHP FLEX-US-21 {320V} compares on 97.52% efficiency, MPPT span, and 120% busbar interconnection.

SMA America certifies SMA America: SHP FLEX-US-21 {320V} (grid-tied PV inverter, active in CEC directory) at 84,904 W AC (equal to the 84,904 W 320 V median). Its 1,195 V DC ceiling pairs with an MPPT window of 495-1,195 V (span 700.0 V). Under NEC 690.8/705.12, 125% sizing demands 3/0 AWG Cu conductors on a 200 A OCPD.

Where Does SMA America: SHP FLEX-US-21 {320V} Fall Across Listed CEC Models?

Position of SMA America: SHP FLEX-US-21 {320V} (84,904 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SHP FLEX-US-21 {320V} (84,904 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SHP F: 84,904 W

What Dataset Percentiles Define SMA America: SHP FLEX-US-21 {320V}?

Percentile placement of SMA America: SHP FLEX-US-21 {320V} across AC power class, conversion efficiency, and backfeed breaker size.

SMA America: SHP FLEX-US-21 {320V} Technical ThresholdsPercentile comparison for SMA America: SHP FLEX-US-21 {320V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output84,904 WCEC Efficiency97.52%Backfeed Breaker200 A

What Do the Dataset Ranks Show for SMA America: SHP FLEX-US-21 {320V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for SMA America: SHP FLEX-US-21 {320V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Eff #543 / 2,343

97.52% CEC Weighted Efficiency

equal to the 97.52% 320 V median; overall power rank #357 (84,904 W, top 15.2%; higher than 84.8% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 153.2 A = 191.5 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

495 V - 1,195 V (Max 1,195 V DC)

Tracking span of 700.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 320 V, 3-phase switchgear (200A Bus / 200A Main (320V) to 1,200A Bus / 1,200A Main (320V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 84903.6W / 320 V 3-phase -> 153.2 A | Breaker >= 1.25 * 153.2 = 191.5 A -> 200 A

CEC Inverters.csv for SMA America: SHP FLEX-US-21 {320V}: Paco=84903.6 W, Vac=320 V, Vdcmax=1195.0 V, Eff=97.52%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (320V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: SHP FLEX-US-21 {320V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for SMA America: SHP FLEX-US-21 {320V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP FLEX-US-21 {320V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 84,904 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 320 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,195 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 495 V - 1,195 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 128.03 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.52% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SMA America: SHP FLEX-US-21 {320V} (320 V, 3-phase)?

Check whether SMA America: SHP FLEX-US-21 {320V} (200 A breaker) fits without main breaker derate or supply-side taps.

Evaluates SMA America: SHP FLEX-US-21 {320V} (200 A required OCPD at 320 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (320V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (320V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (320V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (320V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (320V) 240 A 200 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SMA America: SHP FLEX-US-21 {320V}?

Verified cold-weather (-10 C) series module counts matched to SMA America: SHP FLEX-US-21 {320V}'s 1,195 V DC ceiling.

Sampled CEC PV modules aligned within 495.0-1195.0 V MPPT and 1195.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 12 to 21 panels 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 15 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 15 to 26 panels 11.05 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 18 to 29 panels 5.8 kW

Which Competing Grid-Support Inverters Compare to SMA America: SHP FLEX-US-21 {320V}?

Alternative CEC inverters comparable to SMA America: SHP FLEX-US-21 {320V}, including Ginlong Technologies Co Ltd: S5-GC90K-US {480V} (89,449 W) at 320 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Ginlong Technologies Co Ltd: S5-GC90K-US {480V}
Ginlong Technologies Co Ltd
89,449 W +4545 W 480.0 V 850.0 V 97.99%
Shenzhen Growatt New Energy Co Ltd: WIT 75K-HU-US {480V}
Shenzhen Growatt New Energy Co Ltd
74,589 W -10315 W 480.0 V 800.0 V 96.76%
CSI Solar Co Ltd: CSI-75K-T480GL03-U {480V}
CSI Solar Co Ltd
74,574 W -10330 W 480.0 V 850.0 V 98.17%
Yaskawa Solectria Solar: PVI-100TL-480 {480V}
Yaskawa Solectria Solar
100,000 W +15096 W 480.0 V 850.0 V 98.06%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP FLEX-US-21 {320V}?

Check SMA America: SHP FLEX-US-21 {320V} (84,904 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 320 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (320V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,195 V DC on SMA America: SHP FLEX-US-21 {320V}.

SMA America: SHP FLEX-US-21 {320V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (153.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.52%) and MPPT window (495-1,195 V) directly against Ginlong Technologies Co Ltd: S5-GC90K-US {480V} (89,449 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP FLEX-US-21 {320V} by SMA America covering breaker sizing, MPPT limits, and 320 V, 3-phase interconnection.

What breaker and wire size does SMA America: SHP FLEX-US-21 {320V} require?

At 84,904 W continuous AC (320 V, 3-phase), continuous current is 153.2 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SHP FLEX-US-21 {320V} require?

At 84,904 W AC and 320 V, 3-phase, continuous line current is 153.2 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (320V) or NEC 705.11 interconnection.

How does SMA America: SHP FLEX-US-21 {320V} compare to Ginlong Technologies Co Ltd: S5-GC90K-US {480V}?

SMA America: SHP FLEX-US-21 {320V} delivers 84,904 W AC at 97.52% CEC efficiency with a 1,195 V DC ceiling, while Ginlong Technologies Co Ltd: S5-GC90K-US {480V} outputs 89,449 W at 320 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.