Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: SHP 165-US-21 {630V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SHP 165-US-21 {630V} outputs 165,000 W AC at 630 V, 3-phase (151.2 A continuous, 200 A OCPD), ranking #60 of 2,343 CEC inverters at 98.57% efficiency with a 925-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
165,000 W
AC Voltage
630 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
98.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SHP 165-US-21 {630V} Compare Against Peer CEC Listings?

Breaker sizing (200 A), 3/0 AWG Cu wire rules, and DC input limits for SMA America: SHP 165-US-21 {630V}.

For NEC 705.12 solar interconnection, SMA America: SHP 165-US-21 {630V} outputs 151.2 A continuous AC at 630 V, 3-phase and needs a 200 A backfeed breaker on 3/0 AWG Cu (75 C). Commercial 630 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (630V) or NEC 705.11 supply-side tap. Conversion efficiency scores 98.57% (#60 of 2,343, +1.75 pts vs overall CEC median).

Where Does SMA America: SHP 165-US-21 {630V} Fall Across Listed CEC Models?

Output power comparison showing where SMA America: SHP 165-US-21 {630V} sits among all 2,343 CEC-listed grid-support inverters. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SHP 165-US-21 {630V} (165,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SHP 1: 165,000 W

What Dataset Percentiles Define SMA America: SHP 165-US-21 {630V}?

Relative ranking of SMA America: SHP 165-US-21 {630V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

SMA America: SHP 165-US-21 {630V} Technical ThresholdsPercentile comparison for SMA America: SHP 165-US-21 {630V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output165,000 WCEC Efficiency98.57%Backfeed Breaker200 A

What Do the Dataset Ranks Show for SMA America: SHP 165-US-21 {630V}?

Snapshot of SMA America: SHP 165-US-21 {630V} efficiency rank (#60), OCPD breaker size, MPPT span, and busbar verdict.

Eff #60 / 2,343

98.57% CEC Weighted Efficiency

+0.63 pts vs the 97.94% 630 V median; overall power rank #268 (165,000 W, top 11.4%; higher than 88.6% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 151.2 A = 189.0 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

925 V - 1,200 V (Max 1,200 V DC)

Tracking span of 275.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 630 V, 3-phase switchgear (200A Bus / 200A Main (630V) to 1,200A Bus / 1,200A Main (630V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 165000.0W / 630 V 3-phase -> 151.2 A | Breaker >= 1.25 * 151.2 = 189.0 A -> 200 A

CEC Inverters.csv for SMA America: SHP 165-US-21 {630V}: Paco=165000.0 W, Vac=630 V, Vdcmax=1200.0 V, Eff=98.57%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (630V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: SHP 165-US-21 {630V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SMA America: SHP 165-US-21 {630V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP 165-US-21 {630V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 165,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 630 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 925 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 168.411 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.57% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SMA America: SHP 165-US-21 {630V} (630 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for SMA America: SHP 165-US-21 {630V} at 630 V, 3-phase.

Evaluates SMA America: SHP 165-US-21 {630V} (200 A required OCPD at 630 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (630V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (630V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (630V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (630V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (630V) 240 A 200 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SMA America: SHP 165-US-21 {630V}?

Minimum and maximum series solar module strings fitting SMA America: SHP 165-US-21 {630V} MPPT and 1,200 V limits.

Sampled CEC PV modules aligned within 925.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 28 panels (fixed) 12.32 kW

Which Competing Grid-Support Inverters Compare to SMA America: SHP 165-US-21 {630V}?

Peer 630 V, 3-phase CEC inverters near 165,000 W AC output such as EPC Power Corp: 50-200100 {630V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EPC Power Corp: 50-200100 {630V}
EPC Power Corp
491,262 W +326262 W 630.0 V 1500.0 V 98.39%
TMEIC: PVU-L0840GR {630V}
TMEIC
794,693 W +629693 W 630.0 V 1200.0 V 98.34%
TMEIC Corporation: PVU-L0840URN {630V}
TMEIC Corporation
796,468 W +631468 W 630.0 V 1200.0 V 98.51%
Sungrow Power Supply Co Ltd: SC1575UD-US {630V}
Sungrow Power Supply Co Ltd
1,582,996 W +1417996 W 630.0 V 1500.0 V 98.28%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP 165-US-21 {630V}?

Check SMA America: SHP 165-US-21 {630V} (165,000 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 630 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (630V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SHP 165-US-21 {630V}.

SMA America: SHP 165-US-21 {630V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (151.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.57%) and MPPT window (925-1,200 V) directly against EPC Power Corp: 50-200100 {630V} (491,262 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP 165-US-21 {630V} by SMA America covering breaker sizing, MPPT limits, and 630 V, 3-phase interconnection.

What breaker and wire size does SMA America: SHP 165-US-21 {630V} require?

At 165,000 W continuous AC (630 V, 3-phase), continuous current is 151.2 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SHP 165-US-21 {630V} require?

At 165,000 W AC and 630 V, 3-phase, continuous line current is 151.2 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (630V) or NEC 705.11 interconnection.

How does SMA America: SHP 165-US-21 {630V} compare to EPC Power Corp: 50-200100 {630V}?

SMA America: SHP 165-US-21 {630V} delivers 165,000 W AC at 98.57% CEC efficiency with a 1,200 V DC ceiling, while EPC Power Corp: 50-200100 {630V} outputs 491,262 W at 630 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls