Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: SHP 125-US-20 {480V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SHP 125-US-20 {480V} outputs 125,000 W AC at 480 V, 3-phase (150.4 A continuous, 200 A OCPD), ranking #282 of 2,343 CEC inverters at 98.13% efficiency with a 705-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
125,000 W
AC Voltage
480 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
98.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SHP 125-US-20 {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for SMA America: SHP 125-US-20 {480V}.

Ranking #300 of 2,343 CEC inverters (top 13.4%; higher than 86.6% of peers), SMA America: SHP 125-US-20 {480V} is a grid-tied PV inverter delivering 125,000 W continuous AC at 480 V, 3-phase (150.4 A continuous). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.13% (+0.11 pts vs the 98.02% 480 V median) against peers like Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V} (125,000 W).

Where Does SMA America: SHP 125-US-20 {480V} Fall Across Listed CEC Models?

Marks SMA America: SHP 125-US-20 {480V} (125,000 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SHP 125-US-20 {480V} (125,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SHP 1: 125,000 W

What Dataset Percentiles Define SMA America: SHP 125-US-20 {480V}?

Benchmarks SMA America: SHP 125-US-20 {480V} continuous AC output, 98.13% CEC weighted efficiency, and 200 A OCPD breaker demand.

SMA America: SHP 125-US-20 {480V} Technical ThresholdsPercentile comparison for SMA America: SHP 125-US-20 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output125,000 WCEC Efficiency98.13%Backfeed Breaker200 A

What Do the Dataset Ranks Show for SMA America: SHP 125-US-20 {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining SMA America: SHP 125-US-20 {480V} by SMA America.

Eff #282 / 2,343

98.13% CEC Weighted Efficiency

+0.11 pts vs the 98.02% 480 V median; overall power rank #300 (125,000 W, top 13.4%; higher than 86.6% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 150.4 A = 188.0 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

705 V - 1,200 V (Max 1,200 V DC)

Tracking span of 495.0 V; listed since 2020-02-03 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 125000.0W / 480 V 3-phase -> 150.4 A | Breaker >= 1.25 * 150.4 = 188.0 A -> 200 A

CEC Inverters.csv for SMA America: SHP 125-US-20 {480V}: Paco=125000.0 W, Vac=480 V, Vdcmax=1200.0 V, Eff=98.13%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SMA America: SHP 125-US-20 {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SMA America: SHP 125-US-20 {480V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SHP 125-US-20 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 125,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 705 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 153.468 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.13% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2020-02-03 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to SMA America: SHP 125-US-20 {480V} (480 V, 3-phase)?

Evaluates SMA America: SHP 125-US-20 {480V} (200 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SMA America: SHP 125-US-20 {480V} (200 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (480V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (480V) 240 A 200 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SMA America: SHP 125-US-20 {480V}?

Sample PV string lengths aligned within 705-1,200 V MPPT and 1,200 V DC max at -10 C. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sampled CEC PV modules aligned within 705.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 17 to 21 panels 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 22 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 21 to 26 panels 11.05 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 25 to 29 panels 5.8 kW

Which Competing Grid-Support Inverters Compare to SMA America: SHP 125-US-20 {480V}?

Competing CEC grid-support inverters near 125,000 W AC and 480 V, 3-phase, led by Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V}
Chint Power Systems America
125,000 W Tie (0 W) 480.0 V 1100.0 V 97.2%
Delta Electronics: DES10JB125K01 {480V}
Delta Electronics
125,000 W Tie (0 W) 480.0 V 1000.0 V 97.01%
Delta Electronics: PCS125 {480V}
Delta Electronics
125,000 W Tie (0 W) 480.0 V 1000.0 V 97.01%
Ginlong Technologies Co Ltd: S5-GC125K-US {480V}
Ginlong Technologies Co Ltd
124,991 W -9 W 480.0 V 850.0 V 97.88%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SHP 125-US-20 {480V}?

Check SMA America: SHP 125-US-20 {480V} (125,000 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SHP 125-US-20 {480V}.

SMA America: SHP 125-US-20 {480V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (150.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.13%) and MPPT window (705-1,200 V) directly against Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V} (125,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SHP 125-US-20 {480V} by SMA America covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does SMA America: SHP 125-US-20 {480V} require?

At 125,000 W continuous AC (480 V, 3-phase), continuous current is 150.4 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SHP 125-US-20 {480V} require?

At 125,000 W AC and 480 V, 3-phase, continuous line current is 150.4 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does SMA America: SHP 125-US-20 {480V} compare to Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V}?

SMA America: SHP 125-US-20 {480V} delivers 125,000 W AC at 98.13% CEC efficiency with a 1,200 V DC ceiling, while Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V} outputs 125,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.