Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: SCS 2475-US {385V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SCS 2475-US {385V} outputs 2,078,890 W AC at 385 V, 3-phase (3117.6 A continuous, 3,900 A OCPD), ranking #1,430 of 2,343 CEC inverters at 96.57% efficiency with a 577-950 V MPPT window and 950 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
2,078,890 W
AC Voltage
385 V, 3-phase
Min PV Breaker
3,900 A (parallel Cu feeders)
CEC Efficiency
96.57%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SCS 2475-US {385V} Compare Against Peer CEC Listings?

How SMA America SMA America: SCS 2475-US {385V} compares on 96.57% efficiency, MPPT span, and 120% busbar interconnection.

With a 577-950 V MPPT tracking band and 950 V DC ceiling, SMA America: SCS 2475-US {385V} handles 2,078,890 W continuous AC (208,945 W above the 1,869,945 W 385 V median). Commercial 385 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (385V) or NEC 705.11 supply-side tap. Installers comparing SMA America against Power Electronics: FS2250CU15O3 {600V} (2,420,370 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

Where Does SMA America: SCS 2475-US {385V} Fall Across Listed CEC Models?

Position of SMA America: SCS 2475-US {385V} (2,078,890 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SCS 2475-US {385V} (2,078,890 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SCS 2: 2,078,890 W

What Dataset Percentiles Define SMA America: SCS 2475-US {385V}?

Percentile placement of SMA America: SCS 2475-US {385V} across AC power class, conversion efficiency, and backfeed breaker size.

SMA America: SCS 2475-US {385V} Technical ThresholdsPercentile comparison for SMA America: SCS 2475-US {385V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output2,078,890 WCEC Efficiency96.57%Backfeed Breaker3,900 A

What Do the Dataset Ranks Show for SMA America: SCS 2475-US {385V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for SMA America: SCS 2475-US {385V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Eff #1,430 / 2,343

96.57% CEC Weighted Efficiency

-0.27 pts vs the 96.84% 385 V median; overall power rank #99 (2,078,890 W, top 4.2%; higher than 95.8% of peers).

NEC 705.12 Check

3,900 A Required Backfeed OCPD

125% x 3117.6 A = 3897.0 A -> 3,900 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

577 V - 950 V (Max 950 V DC)

Tracking span of 373.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 385 V, 3-phase switchgear (200A Bus / 200A Main (385V) to 1,200A Bus / 1,200A Main (385V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2078890.0W / 385 V 3-phase -> 3117.6 A | Breaker >= 1.25 * 3117.6 = 3897.0 A -> 3,900 A

CEC Inverters.csv for SMA America: SCS 2475-US {385V}: Paco=2078890.0 W, Vac=385 V, Vdcmax=950.0 V, Eff=96.57%.

Result: Min 3,900 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (385V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for SMA America: SCS 2475-US {385V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for SMA America: SCS 2475-US {385V}.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SCS 2475-US {385V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 2,078,890 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 385 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 950 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 577 V - 950 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 3198.58 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.57% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SMA America: SCS 2475-US {385V} (385 V, 3-phase)?

Check whether SMA America: SCS 2475-US {385V} (3,900 A breaker) fits without main breaker derate or supply-side taps.

Evaluates SMA America: SCS 2475-US {385V} (3900 A required OCPD at 385 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (385V) 40 A 3,900 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (385V) 80 A 3,900 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (385V) 120 A 3,900 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (385V) 160 A 3,900 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (385V) 240 A 3,900 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With SMA America: SCS 2475-US {385V}?

Verified cold-weather (-10 C) series module counts matched to SMA America: SCS 2475-US {385V}'s 950 V DC ceiling.

Sampled CEC PV modules aligned within 577.0-950.0 V MPPT and 950.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 14 to 16 panels 9.44 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 18 to 22 panels 9.68 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 17 to 21 panels 8.93 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 20 to 23 panels 4.6 kW

Which Competing Grid-Support Inverters Compare to SMA America: SCS 2475-US {385V}?

Alternative CEC inverters comparable to SMA America: SCS 2475-US {385V}, including Power Electronics: FS2250CU15O3 {600V} (2,420,370 W) at 385 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Power Electronics: FS2250CU15O3 {600V}
Power Electronics
2,420,370 W +341480 W 600.0 V 1200.0 V 97.82%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W -352190 W 690.0 V 1500.0 V 98.32%
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}
INGETEAM POWER TECHNOLOGY SA
2,467,620 W +388730 W 480.0 V 1300.0 V 96.63%
Schneider Electric USA Inc: CS1666-3-NA {575V}
Schneider Electric USA Inc
1,666,000 W -412890 W 575.0 V 1200.0 V 97.54%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SCS 2475-US {385V}?

Check SMA America: SCS 2475-US {385V} (2,078,890 W AC, 3,900 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 385 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (385V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 950 V DC on SMA America: SCS 2475-US {385V}.

SMA America: SCS 2475-US {385V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 3,900 A OCPD breaker (3117.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.57%) and MPPT window (577-950 V) directly against Power Electronics: FS2250CU15O3 {600V} (2,420,370 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SCS 2475-US {385V} by SMA America covering breaker sizing, MPPT limits, and 385 V, 3-phase interconnection.

What breaker and wire size does SMA America: SCS 2475-US {385V} require?

At 2,078,890 W continuous AC (385 V, 3-phase), continuous current is 3117.6 A; 125% NEC 690.8/705.12 sizing requires a 3,900 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SCS 2475-US {385V} require?

At 2,078,890 W AC and 385 V, 3-phase, continuous line current is 3117.6 A, requiring a 3,900 A OCPD and 1,200A Bus / 1,200A Main (385V) or NEC 705.11 interconnection.

How does SMA America: SCS 2475-US {385V} compare to Power Electronics: FS2250CU15O3 {600V}?

SMA America: SCS 2475-US {385V} delivers 2,078,890 W AC at 96.57% CEC efficiency with a 950 V DC ceiling, while Power Electronics: FS2250CU15O3 {600V} outputs 2,420,370 W at 385 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.