Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SMA America: SB38-1SP-US-41 {240V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SB38-1SP-US-41 {240V} outputs 3,840 W AC at 240 V (16.0 A continuous, 20 A OCPD), ranking #932 of 2,343 CEC inverters at 97.06% efficiency with a 195-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,840 W
AC Voltage
240 V
Min PV Breaker
20 A (12 AWG Cu)
CEC Efficiency
97.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SB38-1SP-US-41 {240V} Compare Against Peer CEC Listings?

Breaker sizing (20 A), 12 AWG Cu wire rules, and DC input limits for SMA America: SB38-1SP-US-41 {240V}.

Classified as a grid-tied PV inverter (listed since 2020-01-21), SMA America: SB38-1SP-US-41 {240V} requires 20.0 A design capacity -> 20 A breaker using 12 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 97.06% (+0.24 pts vs overall CEC median) across 2,343 CEC models, while requires a 20 a breaker, passing directly inside a standard 200 a main / 200 a busbar panel (40 a limit).

Where Does SMA America: SB38-1SP-US-41 {240V} Fall Across Listed CEC Models?

Output power comparison showing where SMA America: SB38-1SP-US-41 {240V} sits among all 2,343 CEC-listed grid-support inverters. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SB38-1SP-US-41 {240V} (3,840 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SB38-: 3,840 W

What Dataset Percentiles Define SMA America: SB38-1SP-US-41 {240V}?

Relative ranking of SMA America: SB38-1SP-US-41 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

SMA America: SB38-1SP-US-41 {240V} Technical ThresholdsPercentile comparison for SMA America: SB38-1SP-US-41 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,840 WCEC Efficiency97.06%Backfeed Breaker20 A

What Do the Dataset Ranks Show for SMA America: SB38-1SP-US-41 {240V}?

Snapshot of SMA America: SB38-1SP-US-41 {240V} efficiency rank (#932), OCPD breaker size, MPPT span, and busbar verdict. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Eff #932 / 2,343

97.06% CEC Weighted Efficiency

+0.38 pts vs the 96.68% 240 V median; overall power rank #1,635 (3,840 W, below CEC median; higher than 30.1% of peers).

NEC 705.12 Check

20 A Required Backfeed OCPD

125% x 16.0 A = 20.0 A -> 20 A standard OCPD using 12 AWG Cu (75 C).

MPPT Window

195 V - 480 V (Max 480 V DC)

Tracking span of 285.0 V; listed since 2020-01-21 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3840.0W / 240 V -> 16.0 A | Breaker >= 1.25 * 16.0 = 20.0 A -> 20 A

CEC Inverters.csv for SMA America: SB38-1SP-US-41 {240V}: Paco=3840.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.06%.

Result: Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for SMA America: SB38-1SP-US-41 {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SMA America: SB38-1SP-US-41 {240V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SB38-1SP-US-41 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,840 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 195 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 10.8389 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.06% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2020-01-21 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for SMA America: SB38-1SP-US-41 {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for SMA America: SB38-1SP-US-41 {240V} at 240 V. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Evaluates SMA America: SB38-1SP-US-41 {240V} (20 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 20 A PASS (120% Rule)
150A Bus / 150A Main 30 A 20 A PASS (120% Rule)
200A Bus / 200A Main 40 A 20 A PASS (120% Rule)
200A Bus / 175A Main 65 A 20 A PASS (120% Rule)
225A Bus / 200A Main 70 A 20 A PASS (120% Rule)

Which CEC PV Module Strings Pair With SMA America: SB38-1SP-US-41 {240V}?

Minimum and maximum series solar module strings fitting SMA America: SB38-1SP-US-41 {240V} MPPT and 480 V limits. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sampled CEC PV modules aligned within 195.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to SMA America: SB38-1SP-US-41 {240V}?

Peer 240 V CEC inverters near 3,840 W AC output such as Delta Electronics: M4-TL-US {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: M4-TL-US {240V}
Delta Electronics
3,840 W Tie (0 W) 240.0 V 480.0 V 97.59%
Delta Electronics: E4-TL-US {240V}
Delta Electronics
3,870 W +30 W 240.0 V 400.0 V 97.99%
Delta Electronics: SOLIVIA 38 NA G4 TL {240V}
Delta Electronics
3,810 W -30 W 240.0 V 500.0 V 97.6%
ABB: PVI-38-OUTD-S-US-A {240V}
ABB
3,800 W -40 W 240.0 V 480.0 V 96.2%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SB38-1SP-US-41 {240V}?

Check SMA America: SB38-1SP-US-41 {240V} (3,840 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on SMA America: SB38-1SP-US-41 {240V}.

SMA America: SB38-1SP-US-41 {240V} Panel & Wire Spec

Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (16.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.06%) and MPPT window (195-480 V) directly against Delta Electronics: M4-TL-US {240V} (3,840 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SB38-1SP-US-41 {240V} by SMA America covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does SMA America: SB38-1SP-US-41 {240V} require?

At 3,840 W continuous AC (240 V), continuous current is 16.0 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.

Does SMA America: SB38-1SP-US-41 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).

How does SMA America: SB38-1SP-US-41 {240V} compare to Delta Electronics: M4-TL-US {240V}?

SMA America: SB38-1SP-US-41 {240V} delivers 3,840 W AC at 97.06% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: M4-TL-US {240V} outputs 3,840 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.