Hoymiles Power Electronics Inc: MIS-500-1NA {240V} outputs 476 W AC at 240 V (2.0 A continuous, 15 A OCPD), ranking #1,239 of 2,343 CEC inverters at 96.75% efficiency with a 32-48 V MPPT window and 48 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
476 W
AC Voltage
240 V
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.75%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hoymiles Power Electronics Inc: MIS-500-1NA {240V} Compare Against Peer CEC Listings?

How Hoymiles Power Electronics Inc Hoymiles Power Electronics Inc: MIS-500-1NA {240V} compares on 96.75% efficiency, MPPT span, and 120% busbar interconnection.

Hoymiles Power Electronics Inc certifies Hoymiles Power Electronics Inc: MIS-500-1NA {240V} (grid-tied PV inverter, active in CEC directory) at 476 W AC (5,300 W below the 5,776 W 240 V median). Its 48 V DC ceiling pairs with an MPPT window of 32-48 V (span 16.0 V). Under NEC 690.8/705.12, 125% sizing demands 14 AWG Cu conductors on a 15 A OCPD.

Where Does Hoymiles Power Electronics Inc: MIS-500-1NA {240V} Fall Across Listed CEC Models?

Position of Hoymiles Power Electronics Inc: MIS-500-1NA {240V} (476 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Hoymiles Power Electronics Inc: MIS-500-1NA {240V} (476 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACHoymiles Power Ele: 476 W

What Dataset Percentiles Define Hoymiles Power Electronics Inc: MIS-500-1NA {240V}?

Percentile placement of Hoymiles Power Electronics Inc: MIS-500-1NA {240V} across AC power class, conversion efficiency, and backfeed breaker size.

Hoymiles Power Electronics Inc: MIS-500-1NA {240V} Technical ThresholdsPercentile comparison for Hoymiles Power Electronics Inc: MIS-500-1NA {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output476 WCEC Efficiency96.75%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Hoymiles Power Electronics Inc: MIS-500-1NA {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Hoymiles Power Electronics Inc: MIS-500-1NA {240V}.

Eff #1,239 / 2,343

96.75% CEC Weighted Efficiency

+0.07 pts vs the 96.68% 240 V median; overall power rank #1,961 (476 W, below CEC median; higher than 16.3% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 2.0 A = 2.5 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

32 V - 48 V (Max 48 V DC)

Tracking span of 16.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 476.4W / 240 V -> 2.0 A | Breaker >= 1.25 * 2.0 = 2.5 A -> 15 A

CEC Inverters.csv for Hoymiles Power Electronics Inc: MIS-500-1NA {240V}: Paco=476.4 W, Vac=240 V, Vdcmax=48.0 V, Eff=96.75%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Hoymiles Power Electronics Inc: MIS-500-1NA {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Hoymiles Power Electronics Inc: MIS-500-1NA {240V}.

Official California Energy Commission (NREL SAM) test parameters for Hoymiles Power Electronics Inc: MIS-500-1NA {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 476 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 48 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 32 V - 48 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 12.309 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.75% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Hoymiles Power Electronics Inc: MIS-500-1NA {240V}?

Check whether Hoymiles Power Electronics Inc: MIS-500-1NA {240V} (15 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Hoymiles Power Electronics Inc: MIS-500-1NA {240V} (15 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 15 A PASS (120% Rule)
150A Bus / 150A Main 30 A 15 A PASS (120% Rule)
200A Bus / 200A Main 40 A 15 A PASS (120% Rule)
200A Bus / 175A Main 65 A 15 A PASS (120% Rule)
225A Bus / 200A Main 70 A 15 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Hoymiles Power Electronics Inc: MIS-500-1NA {240V}?

Verified cold-weather (-10 C) series module counts matched to Hoymiles Power Electronics Inc: MIS-500-1NA {240V}'s 48 V DC ceiling.

Sampled CEC PV modules aligned within 32.0-48.0 V MPPT and 48.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW 270.0 W 42.56 V 1 panel (micro/module) 0.27 kW

Which Competing Grid-Support Inverters Compare to Hoymiles Power Electronics Inc: MIS-500-1NA {240V}?

Alternative CEC inverters comparable to Hoymiles Power Electronics Inc: MIS-500-1NA {240V}, including Altenergy Power System Inc: YC600 {240V} (550 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Altenergy Power System Inc: YC600 {240V}
Altenergy Power System Inc
550 W +74 W 240.0 V 45.0 V 96.51%
Aptos Solar Technology LLC: MAC-400 {240V}
Aptos Solar Technology LLC
382 W -94 W 240.0 V 48.0 V 96.52%
Aptos Solar Technology LLC: MAC-400R {240V}
Aptos Solar Technology LLC
382 W -94 W 240.0 V 48.0 V 96.52%
Cherry Solution Co Ltd: CMI-600S-SA {240V}
Cherry Solution Co Ltd
604 W +128 W 240.0 V 50.0 V 96.12%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Hoymiles Power Electronics Inc: MIS-500-1NA {240V}?

Check Hoymiles Power Electronics Inc: MIS-500-1NA {240V} (476 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 48 V DC on Hoymiles Power Electronics Inc: MIS-500-1NA {240V}.

Hoymiles Power Electronics Inc: MIS-500-1NA {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.75%) and MPPT window (32-48 V) directly against Altenergy Power System Inc: YC600 {240V} (550 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Hoymiles Power Electronics Inc: MIS-500-1NA {240V} by Hoymiles Power Electronics Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Hoymiles Power Electronics Inc: MIS-500-1NA {240V} require?

At 476 W continuous AC (240 V), continuous current is 2.0 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

Does Hoymiles Power Electronics Inc: MIS-500-1NA {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

How does Hoymiles Power Electronics Inc: MIS-500-1NA {240V} compare to Altenergy Power System Inc: YC600 {240V}?

Hoymiles Power Electronics Inc: MIS-500-1NA {240V} delivers 476 W AC at 96.75% CEC efficiency with a 48 V DC ceiling, while Altenergy Power System Inc: YC600 {240V} outputs 550 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.