Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} — CEC Inverter Specifications

Manufacturer: Hoymiles Power Electronics Inc Registry: CEC Verified Engineering Specification

Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} outputs 7,708 W AC at 240 V (32.1 A continuous, 45 A OCPD), ranking #1,019 of 2,343 CEC inverters at 96.99% efficiency with a 300-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
7,708 W
AC Voltage
240 V
Min PV Breaker
45 A (8 AWG Cu)
CEC Efficiency
96.99%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} Compare Against Peer CEC Listings?

Breaker sizing (45 A), 8 AWG Cu wire rules, and DC input limits for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}.

Classified as a hybrid battery-capable inverter (listed since 2025-08-01), Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} requires 40.1 A design capacity -> 45 A breaker using 8 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 96.99% (+0.17 pts vs overall CEC median) across 2,343 CEC models, while its 45 a backfeed breaker exceeds a 200a/200a panel's 40 a ceiling, requiring a 175 a main derate, 225 a busbar, or nec 705.11 tap.

Where Does Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} Fall Across Listed CEC Models?

Output power comparison showing where Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} (7,708 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACHoymiles Power Ele: 7,708 W

What Dataset Percentiles Define Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?

Relative ranking of Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} Technical ThresholdsPercentile comparison for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output7,708 WCEC Efficiency96.99%Backfeed Breaker45 A

What Do the Dataset Ranks Show for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?

Snapshot of Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} efficiency rank (#1,019), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,019 / 2,343

96.99% CEC Weighted Efficiency

+0.31 pts vs the 96.68% 240 V median; overall power rank #1,160 (7,708 W, top 49.5%; higher than 50.5% of peers).

NEC 705.12 Check

45 A Required Backfeed OCPD

125% x 32.1 A = 40.1 A -> 45 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

300 V - 480 V (Max 480 V DC)

Tracking span of 180.0 V; listed since 2025-08-01 (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7708.0W / 240 V -> 32.1 A | Breaker >= 1.25 * 32.1 = 40.1 A -> 45 A

CEC Inverters.csv for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}: Paco=7708.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.99%.

Result: Min 45 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 7,708 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 300 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 20.9133 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.99% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-08-01 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} at 240 V.

Evaluates Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} (45 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 45 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 45 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 45 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 45 A PASS (120% Rule)
225A Bus / 200A Main 70 A 45 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?

Minimum and maximum series solar module strings fitting Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} MPPT and 480 V limits.

Sampled CEC PV modules aligned within 300.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 7 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 9 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 9 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 11 panels (fixed) 2.2 kW

Which Competing Grid-Support Inverters Compare to Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?

Peer 240 V CEC inverters near 7,708 W AC output such as Delta Electronics: E8_BDI {240V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: E8_BDI {240V}
Delta Electronics
7,716 W +8 W 240.0 V 480.0 V 97.27%
Delta Electronics: E8 Plus-TL-US {240V}
Delta Electronics
7,716 W +8 W 240.0 V 480.0 V 97.27%
Delta Electronics: E8 Plus-TL-US(AC) {240V}
Delta Electronics
7,720 W +12 W 240.0 V 480.0 V 97.97%
Anker Innovations Limited: A17E1 {240V}
Anker Innovations Limited
7,687 W -21 W 240.0 V 450.0 V 95.96%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?

Check Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} (7,708 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}.

Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (32.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.99%) and MPPT window (300-480 V) directly against Delta Electronics: E8_BDI {240V} (7,716 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} by Hoymiles Power Electronics Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} require?

At 7,708 W continuous AC (240 V), continuous current is 32.1 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.

Does Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 45 A at 240 V means Needs Derate / Tap 705.11.

How does Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} compare to Delta Electronics: E8_BDI {240V}?

Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} delivers 7,708 W AC at 96.99% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: E8_BDI {240V} outputs 7,716 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.