Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} outputs 7,708 W AC at 240 V (32.1 A continuous, 45 A OCPD), ranking #1,019 of 2,343 CEC inverters at 96.99% efficiency with a 300-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 7,708 W
- AC Voltage
- 240 V
- Min PV Breaker
- 45 A (8 AWG Cu)
- CEC Efficiency
- 96.99%
How Does Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} Compare Against Peer CEC Listings?
Breaker sizing (45 A), 8 AWG Cu wire rules, and DC input limits for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}.
Classified as a hybrid battery-capable inverter (listed since 2025-08-01), Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} requires 40.1 A design capacity -> 45 A breaker using 8 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 96.99% (+0.17 pts vs overall CEC median) across 2,343 CEC models, while its 45 a backfeed breaker exceeds a 200a/200a panel's 40 a ceiling, requiring a 175 a main derate, 225 a busbar, or nec 705.11 tap.
Where Does Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} Fall Across Listed CEC Models?
Output power comparison showing where Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} sits among all 2,343 CEC-listed grid-support inverters.
What Dataset Percentiles Define Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?
Relative ranking of Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?
Snapshot of Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} efficiency rank (#1,019), OCPD breaker size, MPPT span, and busbar verdict.
96.99% CEC Weighted Efficiency
+0.31 pts vs the 96.68% 240 V median; overall power rank #1,160 (7,708 W, top 49.5%; higher than 50.5% of peers).
45 A Required Backfeed OCPD
125% x 32.1 A = 40.1 A -> 45 A standard OCPD using 8 AWG Cu (75 C).
300 V - 480 V (Max 480 V DC)
Tracking span of 180.0 V; listed since 2025-08-01 (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 7708.0W / 240 V -> 32.1 A | Breaker >= 1.25 * 32.1 = 40.1 A -> 45 A
CEC Inverters.csv for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}: Paco=7708.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.99%.
Result: Min 45 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 7,708 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 300 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 20.9133 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.99% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2025-08-01 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?
NEC 705.12(B)(3)(2) backfeed compliance table for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} at 240 V.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 45 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 45 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 45 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 45 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 45 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?
Minimum and maximum series solar module strings fitting Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} MPPT and 480 V limits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 9 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 9 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 11 panels (fixed) | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?
Peer 240 V CEC inverters near 7,708 W AC output such as Delta Electronics: E8_BDI {240V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: E8_BDI {240V} Delta Electronics |
7,716 W | +8 W | 240.0 V | 480.0 V | 97.27% |
| Delta Electronics: E8 Plus-TL-US {240V} Delta Electronics |
7,716 W | +8 W | 240.0 V | 480.0 V | 97.27% |
| Delta Electronics: E8 Plus-TL-US(AC) {240V} Delta Electronics |
7,720 W | +12 W | 240.0 V | 480.0 V | 97.97% |
| Anker Innovations Limited: A17E1 {240V} Anker Innovations Limited |
7,687 W | -21 W | 240.0 V | 450.0 V | 95.96% |
What Are the Interconnection Limits and Best-Fit Uses for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}?
Check Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} (7,708 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V}.
Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (32.1 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.99%) and MPPT window (300-480 V) directly against Delta Electronics: E8_BDI {240V} (7,716 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} by Hoymiles Power Electronics Inc covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} require?
At 7,708 W continuous AC (240 V), continuous current is 32.1 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.
Does Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 45 A at 240 V means Needs Derate / Tap 705.11.
How does Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} compare to Delta Electronics: E8_BDI {240V}?
Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V} delivers 7,708 W AC at 96.99% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: E8_BDI {240V} outputs 7,716 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)