Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} outputs 9,641 W AC at 240 V (40.2 A continuous, 60 A OCPD), ranking #1,225 of 2,343 CEC inverters at 96.76% efficiency with a 300-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 9,641 W
- AC Voltage
- 240 V
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 96.76%
How Does Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V}.
Ranking #961 of 2,343 CEC inverters (top 41.0%; higher than 59.0% of peers), Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} is a hybrid battery-capable inverter delivering 9,641 W continuous AC at 240 V (40.2 A continuous). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Weighted CEC efficiency reaches 96.76% (+0.08 pts vs the 96.68% 240 V median) against peers like Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} (9,648 W).
Where Does Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} Fall Across Listed CEC Models?
Marks Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} (9,641 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V}?
Benchmarks Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} continuous AC output, 96.76% CEC weighted efficiency, and 60 A OCPD breaker demand.
What Do the Dataset Ranks Show for Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} by Hoymiles Power Electronics Inc.
96.76% CEC Weighted Efficiency
+0.08 pts vs the 96.68% 240 V median; overall power rank #961 (9,641 W, top 41.0%; higher than 59.0% of peers).
60 A Required Backfeed OCPD
125% x 40.2 A = 50.2 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
300 V - 480 V (Max 480 V DC)
Tracking span of 180.0 V; listed since 2025-08-01 (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 9641.0W / 240 V -> 40.2 A | Breaker >= 1.25 * 40.2 = 50.2 A -> 60 A
CEC Inverters.csv for Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V}: Paco=9641.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.76%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 9,641 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 300 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 26.2207 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.76% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2025-08-01 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V}?
Evaluates Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} (60 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 60 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 60 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 60 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V}?
Sample PV string lengths aligned within 300-480 V MPPT and 480 V DC max at -10 C. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 9 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 9 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 11 panels (fixed) | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V}?
Competing CEC grid-support inverters near 9,641 W AC and 240 V, led by Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} Dyness Digital Energy Technology Co LTD |
9,648 W | +7 W | 240.0 V | 500.0 V | 96.56% |
| Delta Electronics: E10-TL-US(AC) {240V} Delta Electronics |
9,632 W | -9 W | 240.0 V | 480.0 V | 97.79% |
| Alpha ESS Co Ltd: SMILE-SP96-INV {240V} Alpha ESS Co Ltd |
9,628 W | -13 W | 240.0 V | 480.0 V | 96.73% |
| Delta Electronics: M10-TL-US {240V} Delta Electronics |
9,620 W | -21 W | 240.0 V | 480.0 V | 97.07% |
What Are the Interconnection Limits and Best-Fit Uses for Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V}?
Check Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} (9,641 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V}.
Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (40.2 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.76%) and MPPT window (300-480 V) directly against Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} (9,648 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} by Hoymiles Power Electronics Inc covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} require?
At 9,641 W continuous AC (240 V), continuous current is 40.2 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
Does Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.
How does Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} compare to Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}?
Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V} delivers 9,641 W AC at 96.76% CEC efficiency with a 480 V DC ceiling, while Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} outputs 9,648 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)