Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} — CEC Inverter Specifications

Manufacturer: Dyness Digital Energy Technology Co LTD Registry: CEC Verified Engineering Specification

Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} outputs 9,648 W AC at 240 V (40.2 A continuous, 60 A OCPD), ranking #1,467 of 2,343 CEC inverters at 96.56% efficiency with a 170-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
9,648 W
AC Voltage
240 V
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
96.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,467), 170-500 V MPPT tracking, and panel fit for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}.

Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} from Dyness Digital Energy Technology Co LTD outputs 40.2 A continuous AC at 240 V (9,648 W AC, rank #959). Paired with 6 AWG Cu conductors and a 60 A OCPD, its 96.56% CEC efficiency compares closely with Delta Electronics: E10-TL-US(AC) {240V} (9,632 W). Keep NEC 690.7 winter string Voc below 500 V DC.

Where Does Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} at 9,648 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} (9,648 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDyness Digital Ene: 9,648 W

What Dataset Percentiles Define Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}?

Dataset percentiles comparing Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} against 2,343 certified grid-support inverters nationwide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} Technical ThresholdsPercentile comparison for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output9,648 WCEC Efficiency96.56%Backfeed Breaker60 A

What Do the Dataset Ranks Show for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}?

Engineering highlights for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} covering efficiency, 6 AWG Cu feeder, and panel compatibility.

Eff #1,467 / 2,343

96.56% CEC Weighted Efficiency

-0.12 pts vs the 96.68% 240 V median; overall power rank #959 (9,648 W, top 40.9%; higher than 59.1% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 40.2 A = 50.2 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

170 V - 500 V (Max 500 V DC)

Tracking span of 330.0 V; listed since 2024-01-22 (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 9648.0W / 240 V -> 40.2 A | Breaker >= 1.25 * 40.2 = 50.2 A -> 60 A

CEC Inverters.csv for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}: Paco=9648.0 W, Vac=240 V, Vdcmax=500.0 V, Eff=96.56%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}?

California Energy Commission Solar Equipment List parameters for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 9,648 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 170 V - 500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 25.6192 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.56% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-01-22 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}?

Panelboard and switchgear backfeed allowances for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} (60 A OCPD). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} (60 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 60 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 60 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 60 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 60 A PASS (120% Rule)
225A Bus / 200A Main 70 A 60 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}.

Sampled CEC PV modules aligned within 170.0-500.0 V MPPT and 500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 4 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 5 to 11 panels 4.67 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 6 to 12 panels 2.4 kW

Which Competing Grid-Support Inverters Compare to Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}?

Four alternative CEC inverters matched to Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} (9,648 W AC), led by Delta Electronics: E10-TL-US(AC) {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: E10-TL-US(AC) {240V}
Delta Electronics
9,632 W -16 W 240.0 V 480.0 V 97.79%
Alpha ESS Co Ltd: SMILE-SP96-INV {240V}
Alpha ESS Co Ltd
9,628 W -20 W 240.0 V 480.0 V 96.73%
Delta Electronics: E10_BDI {240V}
Delta Electronics
9,674 W +26 W 240.0 V 480.0 V 97.21%
Delta Electronics: E10-TL-US {240V}
Delta Electronics
9,674 W +26 W 240.0 V 480.0 V 97.21%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}?

Check Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} (9,648 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on Dyness Digital Energy Technology Co LTD: TX96K-HM {240V}.

Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (40.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.56%) and MPPT window (170-500 V) directly against Delta Electronics: E10-TL-US(AC) {240V} (9,632 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} by Dyness Digital Energy Technology Co LTD covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} require?

At 9,648 W continuous AC (240 V), continuous current is 40.2 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

Does Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

How does Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} compare to Delta Electronics: E10-TL-US(AC) {240V}?

Dyness Digital Energy Technology Co LTD: TX96K-HM {240V} delivers 9,648 W AC at 96.56% CEC efficiency with a 500 V DC ceiling, while Delta Electronics: E10-TL-US(AC) {240V} outputs 9,632 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.