Cherry Solution Co Ltd: CMI-600S-SA {240V} outputs 604 W AC at 240 V (2.5 A continuous, 15 A OCPD), ranking #1,877 of 2,343 CEC inverters at 96.12% efficiency with a 35-50 V MPPT window and 50 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 604 W
- AC Voltage
- 240 V
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 96.12%
How Does Cherry Solution Co Ltd: CMI-600S-SA {240V} Compare Against Peer CEC Listings?
How Cherry Solution Co Ltd Cherry Solution Co Ltd: CMI-600S-SA {240V} compares on 96.12% efficiency, MPPT span, and 120% busbar interconnection.
With a 35-50 V MPPT tracking band and 50 V DC ceiling, Cherry Solution Co Ltd: CMI-600S-SA {240V} handles 604 W continuous AC (5,172 W below the 5,776 W 240 V median). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Installers comparing Cherry Solution Co Ltd against Altenergy Power System Inc: DS3-S {240V} (656 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.
Where Does Cherry Solution Co Ltd: CMI-600S-SA {240V} Fall Across Listed CEC Models?
Position of Cherry Solution Co Ltd: CMI-600S-SA {240V} (604 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Cherry Solution Co Ltd: CMI-600S-SA {240V}?
Percentile placement of Cherry Solution Co Ltd: CMI-600S-SA {240V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Cherry Solution Co Ltd: CMI-600S-SA {240V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Cherry Solution Co Ltd: CMI-600S-SA {240V}.
96.12% CEC Weighted Efficiency
-0.56 pts vs the 96.68% 240 V median; overall power rank #1,928 (604 W, below CEC median; higher than 17.7% of peers).
15 A Required Backfeed OCPD
125% x 2.5 A = 3.1 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
35 V - 50 V (Max 50 V DC)
Tracking span of 15.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 604.0W / 240 V -> 2.5 A | Breaker >= 1.25 * 2.5 = 3.1 A -> 15 A
CEC Inverters.csv for Cherry Solution Co Ltd: CMI-600S-SA {240V}: Paco=604.0 W, Vac=240 V, Vdcmax=50.0 V, Eff=96.12%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Cherry Solution Co Ltd: CMI-600S-SA {240V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Cherry Solution Co Ltd: CMI-600S-SA {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 604 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 50 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 35 V - 50 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 14.9613 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.12% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Cherry Solution Co Ltd: CMI-600S-SA {240V}?
Check whether Cherry Solution Co Ltd: CMI-600S-SA {240V} (15 A breaker) fits without main breaker derate or supply-side taps.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 15 A | PASS (120% Rule) |
| 150A Bus / 150A Main | 30 A | 15 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 15 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 15 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 15 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Cherry Solution Co Ltd: CMI-600S-SA {240V}?
Verified cold-weather (-10 C) series module counts matched to Cherry Solution Co Ltd: CMI-600S-SA {240V}'s 50 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |
Which Competing Grid-Support Inverters Compare to Cherry Solution Co Ltd: CMI-600S-SA {240V}?
Alternative CEC inverters comparable to Cherry Solution Co Ltd: CMI-600S-SA {240V}, including Altenergy Power System Inc: DS3-S {240V} (656 W) at 240 V.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Altenergy Power System Inc: DS3-S {240V} Altenergy Power System Inc |
656 W | +52 W | 240.0 V | 43.0 V | 97.23% |
| Anker Innovations Limited: MI80S {240V} Anker Innovations Limited |
656 W | +52 W | 240.0 V | 43.0 V | 97.23% |
| Altenergy Power System Inc: YC600 {240V} Altenergy Power System Inc |
550 W | -54 W | 240.0 V | 45.0 V | 96.51% |
| Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {240V} Chilicon Power LLC |
721 W | +117 W | 240.0 V | 70.0 V | 95.35% |
What Are the Interconnection Limits and Best-Fit Uses for Cherry Solution Co Ltd: CMI-600S-SA {240V}?
Check Cherry Solution Co Ltd: CMI-600S-SA {240V} (604 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 50 V DC on Cherry Solution Co Ltd: CMI-600S-SA {240V}.
Cherry Solution Co Ltd: CMI-600S-SA {240V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.5 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.12%) and MPPT window (35-50 V) directly against Altenergy Power System Inc: DS3-S {240V} (656 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Cherry Solution Co Ltd: CMI-600S-SA {240V} by Cherry Solution Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Cherry Solution Co Ltd: CMI-600S-SA {240V} require?
At 604 W continuous AC (240 V), continuous current is 2.5 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
Does Cherry Solution Co Ltd: CMI-600S-SA {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).
How does Cherry Solution Co Ltd: CMI-600S-SA {240V} compare to Altenergy Power System Inc: DS3-S {240V}?
Cherry Solution Co Ltd: CMI-600S-SA {240V} delivers 604 W AC at 96.12% CEC efficiency with a 50 V DC ceiling, while Altenergy Power System Inc: DS3-S {240V} outputs 656 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)