Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Altenergy Power System Inc: YC600 {240V} — CEC Inverter Specifications

Manufacturer: Altenergy Power System Inc Registry: CEC Verified Engineering Specification

Altenergy Power System Inc: YC600 {240V} outputs 550 W AC at 240 V (2.3 A continuous, 15 A OCPD), ranking #1,537 of 2,343 CEC inverters at 96.51% efficiency with a 24-45 V MPPT window and 45 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
550 W
AC Voltage
240 V
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Altenergy Power System Inc: YC600 {240V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Altenergy Power System Inc: YC600 {240V}.

Classified as a grid-tied PV inverter (listed since 2020-04-13), Altenergy Power System Inc: YC600 {240V} requires 2.9 A design capacity -> 15 A breaker using 14 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 96.51% (-0.31 pts vs overall CEC median) across 2,343 CEC models, while module-level microinverter output eliminates high-voltage dc rooftop strings and connects via a 240v ac trunk circuit.

Where Does Altenergy Power System Inc: YC600 {240V} Fall Across Listed CEC Models?

Output power comparison showing where Altenergy Power System Inc: YC600 {240V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Altenergy Power System Inc: YC600 {240V} (550 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACAltenergy Power Sy: 550 W

What Dataset Percentiles Define Altenergy Power System Inc: YC600 {240V}?

Relative ranking of Altenergy Power System Inc: YC600 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Altenergy Power System Inc: YC600 {240V} Technical ThresholdsPercentile comparison for Altenergy Power System Inc: YC600 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output550 WCEC Efficiency96.51%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Altenergy Power System Inc: YC600 {240V}?

Snapshot of Altenergy Power System Inc: YC600 {240V} efficiency rank (#1,537), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,537 / 2,343

96.51% CEC Weighted Efficiency

-0.17 pts vs the 96.68% 240 V median; overall power rank #1,941 (550 W, below CEC median; higher than 17.1% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 2.3 A = 2.9 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

24 V - 45 V (Max 45 V DC)

Tracking span of 21.0 V; listed since 2020-04-13 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 550.0W / 240 V -> 2.3 A | Breaker >= 1.25 * 2.3 = 2.9 A -> 15 A

CEC Inverters.csv for Altenergy Power System Inc: YC600 {240V}: Paco=550.0 W, Vac=240 V, Vdcmax=45.0 V, Eff=96.51%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Altenergy Power System Inc: YC600 {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Altenergy Power System Inc: YC600 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Altenergy Power System Inc: YC600 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 550 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 45 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 24 V - 45 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 15.8306 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.51% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2020-04-13 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Altenergy Power System Inc: YC600 {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Altenergy Power System Inc: YC600 {240V} at 240 V.

Evaluates Altenergy Power System Inc: YC600 {240V} (15 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 15 A PASS (120% Rule)
150A Bus / 150A Main 30 A 15 A PASS (120% Rule)
200A Bus / 200A Main 40 A 15 A PASS (120% Rule)
200A Bus / 175A Main 65 A 15 A PASS (120% Rule)
225A Bus / 200A Main 70 A 15 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Altenergy Power System Inc: YC600 {240V}?

Minimum and maximum series solar module strings fitting Altenergy Power System Inc: YC600 {240V} MPPT and 45 V limits.

Sampled CEC PV modules aligned within 24.0-45.0 V MPPT and 45.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW 270.0 W 42.56 V 1 panel (micro/module) 0.27 kW

Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: YC600 {240V}?

Peer 240 V CEC inverters near 550 W AC output such as Cherry Solution Co Ltd: CMI-600S-SA {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Cherry Solution Co Ltd: CMI-600S-SA {240V}
Cherry Solution Co Ltd
604 W +54 W 240.0 V 50.0 V 96.12%
Cherry Solution Co Ltd: CMI-600S-WA {240V}
Cherry Solution Co Ltd
604 W +54 W 240.0 V 50.0 V 96.12%
Anker Innovations Limited: MI80S {240V}
Anker Innovations Limited
656 W +106 W 240.0 V 43.0 V 97.23%
Aptos Solar Technology LLC: MAC-400 {240V}
Aptos Solar Technology LLC
382 W -168 W 240.0 V 48.0 V 96.52%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: YC600 {240V}?

Check Altenergy Power System Inc: YC600 {240V} (550 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 45 V DC on Altenergy Power System Inc: YC600 {240V}.

Altenergy Power System Inc: YC600 {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.51%) and MPPT window (24-45 V) directly against Cherry Solution Co Ltd: CMI-600S-SA {240V} (604 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Altenergy Power System Inc: YC600 {240V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Altenergy Power System Inc: YC600 {240V} require?

At 550 W continuous AC (240 V), continuous current is 2.3 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

Does Altenergy Power System Inc: YC600 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

How does Altenergy Power System Inc: YC600 {240V} compare to Cherry Solution Co Ltd: CMI-600S-SA {240V}?

Altenergy Power System Inc: YC600 {240V} delivers 550 W AC at 96.51% CEC efficiency with a 45 V DC ceiling, while Cherry Solution Co Ltd: CMI-600S-SA {240V} outputs 604 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.