Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Altenergy Power System Inc: ELS-96 {208V} — CEC Inverter Specifications

Manufacturer: Altenergy Power System Inc Registry: CEC Verified Engineering Specification

Altenergy Power System Inc: ELS-96 {208V} outputs 8,308 W AC at 208 V, commercial single-phase (39.9 A continuous, 50 A OCPD), ranking #2,323 of 2,343 CEC inverters at 93.5% efficiency with a 51-60 V MPPT window and 60 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
8,308 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
50 A (8 AWG Cu)
CEC Efficiency
93.5%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Altenergy Power System Inc: ELS-96 {208V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 208 V, commercial single-phase grid-support overview for Altenergy Power System Inc: ELS-96 {208V}.

Ranking #1,082 of 2,343 CEC inverters (top 46.2%; higher than 53.8% of peers), Altenergy Power System Inc: ELS-96 {208V} is a grid-tied PV inverter delivering 8,308 W continuous AC at 208 V, commercial single-phase (39.9 A continuous). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 93.5% (-2.91 pts vs the 96.41% 208 V median) against peers like Delta Electronics: E10-TL-US(AC) {208V} (8,327 W).

Where Does Altenergy Power System Inc: ELS-96 {208V} Fall Across Listed CEC Models?

Marks Altenergy Power System Inc: ELS-96 {208V} (8,308 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Altenergy Power System Inc: ELS-96 {208V} (8,308 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACAltenergy Power Sy: 8,308 W

What Dataset Percentiles Define Altenergy Power System Inc: ELS-96 {208V}?

Benchmarks Altenergy Power System Inc: ELS-96 {208V} continuous AC output, 93.5% CEC weighted efficiency, and 50 A OCPD breaker demand.

Altenergy Power System Inc: ELS-96 {208V} Technical ThresholdsPercentile comparison for Altenergy Power System Inc: ELS-96 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output8,308 WCEC Efficiency93.5%Backfeed Breaker50 A

What Do the Dataset Ranks Show for Altenergy Power System Inc: ELS-96 {208V}?

Four key NEC 705.12 and California Energy Commission metrics defining Altenergy Power System Inc: ELS-96 {208V} by Altenergy Power System Inc.

Eff #2,323 / 2,343

93.5% CEC Weighted Efficiency

-2.91 pts vs the 96.41% 208 V median; overall power rank #1,082 (8,308 W, top 46.2%; higher than 53.8% of peers).

NEC 705.12 Check

50 A Required Backfeed OCPD

125% x 39.9 A = 49.9 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

51 V - 60 V (Max 60 V DC)

Tracking span of 9.0 V; listed since 2025-01-13 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 8308.0W / 208 V -> 39.9 A | Breaker >= 1.25 * 39.9 = 49.9 A -> 50 A

CEC Inverters.csv for Altenergy Power System Inc: ELS-96 {208V}: Paco=8308.0 W, Vac=208 V, Vdcmax=60.0 V, Eff=93.5%.

Result: Min 50 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Altenergy Power System Inc: ELS-96 {208V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Altenergy Power System Inc: ELS-96 {208V}.

Official California Energy Commission (NREL SAM) test parameters for Altenergy Power System Inc: ELS-96 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 8,308 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 60 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 51 V - 60 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 158.678 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 93.5% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-01-13 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Altenergy Power System Inc: ELS-96 {208V} (208 V, commercial single-phase)?

Evaluates Altenergy Power System Inc: ELS-96 {208V} (50 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Altenergy Power System Inc: ELS-96 {208V} (50 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 50 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 50 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 50 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 50 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 50 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Altenergy Power System Inc: ELS-96 {208V}?

Sample PV string lengths aligned within 51-60 V MPPT and 60 V DC max at -10 C. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sampled CEC PV modules aligned within 51.0-60.0 V MPPT and 60.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 1 panel (micro/module) 0.59 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW

Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: ELS-96 {208V}?

Competing CEC grid-support inverters near 8,308 W AC and 208 V, commercial single-phase, led by Delta Electronics: E10-TL-US(AC) {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: E10-TL-US(AC) {208V}
Delta Electronics
8,327 W +19 W 208.0 V 480.0 V 97.45%
Delta Electronics: M10-TL-US {208V}
Delta Electronics
8,360 W +52 W 208.0 V 480.0 V 96.83%
Delta Electronics: M10-4-TL-US {208V}
Delta Electronics
8,385 W +77 W 208.0 V 480.0 V 96.94%
Delta Electronics: E10_BDI {208V}
Delta Electronics
8,400 W +92 W 208.0 V 480.0 V 96.86%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: ELS-96 {208V}?

Check Altenergy Power System Inc: ELS-96 {208V} (8,308 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 60 V DC on Altenergy Power System Inc: ELS-96 {208V}.

Altenergy Power System Inc: ELS-96 {208V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (39.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (93.5%) and MPPT window (51-60 V) directly against Delta Electronics: E10-TL-US(AC) {208V} (8,327 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Altenergy Power System Inc: ELS-96 {208V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Altenergy Power System Inc: ELS-96 {208V} require?

At 8,308 W continuous AC (208 V, commercial single-phase), continuous current is 39.9 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Altenergy Power System Inc: ELS-96 {208V} require?

At 8,308 W AC and 208 V, commercial single-phase, continuous line current is 39.9 A, requiring a 50 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Altenergy Power System Inc: ELS-96 {208V} compare to Delta Electronics: E10-TL-US(AC) {208V}?

Altenergy Power System Inc: ELS-96 {208V} delivers 8,308 W AC at 93.5% CEC efficiency with a 60 V DC ceiling, while Delta Electronics: E10-TL-US(AC) {208V} outputs 8,327 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.