Altenergy Power System Inc: ELS-76 {208V} outputs 6,606 W AC at 208 V, commercial single-phase (31.8 A continuous, 40 A OCPD), ranking #2,317 of 2,343 CEC inverters at 93.96% efficiency with a 51-60 V MPPT window and 60 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 6,606 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 40 A (8 AWG Cu)
- CEC Efficiency
- 93.96%
How Does Altenergy Power System Inc: ELS-76 {208V} Compare Against Peer CEC Listings?
Breaker sizing (40 A), 8 AWG Cu wire rules, and DC input limits for Altenergy Power System Inc: ELS-76 {208V}.
Classified as a grid-tied PV inverter (listed since 2025-01-13), Altenergy Power System Inc: ELS-76 {208V} requires 39.8 A design capacity -> 40 A breaker using 8 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 93.96% (-2.86 pts vs overall CEC median) across 2,343 CEC models, while commercial 208 v, commercial single-phase switchgear interconnection uses 1,200a bus / 1,200a main (208v) or nec 705.11 supply-side tap.
Where Does Altenergy Power System Inc: ELS-76 {208V} Fall Across Listed CEC Models?
Output power comparison showing where Altenergy Power System Inc: ELS-76 {208V} sits among all 2,343 CEC-listed grid-support inverters.
What Dataset Percentiles Define Altenergy Power System Inc: ELS-76 {208V}?
Relative ranking of Altenergy Power System Inc: ELS-76 {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for Altenergy Power System Inc: ELS-76 {208V}?
Snapshot of Altenergy Power System Inc: ELS-76 {208V} efficiency rank (#2,317), OCPD breaker size, MPPT span, and busbar verdict.
93.96% CEC Weighted Efficiency
-2.45 pts vs the 96.41% 208 V median; overall power rank #1,330 (6,606 W, below CEC median; higher than 43.2% of peers).
40 A Required Backfeed OCPD
125% x 31.8 A = 39.8 A -> 40 A standard OCPD using 8 AWG Cu (75 C).
51 V - 60 V (Max 60 V DC)
Tracking span of 9.0 V; listed since 2025-01-13 (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 6606.0W / 208 V -> 31.8 A | Breaker >= 1.25 * 31.8 = 39.8 A -> 40 A
CEC Inverters.csv for Altenergy Power System Inc: ELS-76 {208V}: Paco=6606.0 W, Vac=208 V, Vdcmax=60.0 V, Eff=93.96%.
Result: Min 40 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Altenergy Power System Inc: ELS-76 {208V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Altenergy Power System Inc: ELS-76 {208V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 6,606 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 60 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 51 V - 60 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 125.551 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 93.96% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2025-01-13 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Altenergy Power System Inc: ELS-76 {208V} (208 V, commercial single-phase)?
NEC 705.12(B)(3)(2) backfeed compliance table for Altenergy Power System Inc: ELS-76 {208V} at 208 V, commercial single-phase.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 40 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (208V) | 80 A | 40 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 40 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 40 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 40 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Altenergy Power System Inc: ELS-76 {208V}?
Minimum and maximum series solar module strings fitting Altenergy Power System Inc: ELS-76 {208V} MPPT and 60 V limits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 1 panel (micro/module) | 0.59 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: ELS-76 {208V}?
Peer 208 V, commercial single-phase CEC inverters near 6,606 W AC output such as Delta Electronics: SOLIVIA 66 NA G4 TL {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: SOLIVIA 66 NA G4 TL {208V} Delta Electronics |
6,600 W | -6 W | 208.0 V | 500.0 V | 97.02% |
| Delta Electronics: SOLIVIA 76 NA G4 TL {208V} Delta Electronics |
6,600 W | -6 W | 208.0 V | 500.0 V | 97.02% |
| Delta Electronics: E8-TL-US {208V} Delta Electronics |
6,656 W | +50 W | 208.0 V | 480.0 V | 97.21% |
| Delta Electronics: M8-TL-US {208V} Delta Electronics |
6,660 W | +54 W | 208.0 V | 480.0 V | 97.23% |
What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: ELS-76 {208V}?
Check Altenergy Power System Inc: ELS-76 {208V} (6,606 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 60 V DC on Altenergy Power System Inc: ELS-76 {208V}.
Altenergy Power System Inc: ELS-76 {208V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (31.8 A continuous).
Alternative Inverter Comparison
Compare efficiency (93.96%) and MPPT window (51-60 V) directly against Delta Electronics: SOLIVIA 66 NA G4 TL {208V} (6,600 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Altenergy Power System Inc: ELS-76 {208V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does Altenergy Power System Inc: ELS-76 {208V} require?
At 6,606 W continuous AC (208 V, commercial single-phase), continuous current is 31.8 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Altenergy Power System Inc: ELS-76 {208V} require?
At 6,606 W AC and 208 V, commercial single-phase, continuous line current is 31.8 A, requiring a 40 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Altenergy Power System Inc: ELS-76 {208V} compare to Delta Electronics: SOLIVIA 66 NA G4 TL {208V}?
Altenergy Power System Inc: ELS-76 {208V} delivers 6,606 W AC at 93.96% CEC efficiency with a 60 V DC ceiling, while Delta Electronics: SOLIVIA 66 NA G4 TL {208V} outputs 6,600 W at 208 V, commercial single-phase.