Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Altenergy Power System Inc: ELS-114 {208V} — CEC Inverter Specifications

Manufacturer: Altenergy Power System Inc Registry: CEC Verified Engineering Specification

Altenergy Power System Inc: ELS-114 {208V} outputs 10,011 W AC at 208 V, commercial single-phase (48.1 A continuous, 70 A OCPD), ranking #2,329 of 2,343 CEC inverters at 92.83% efficiency with a 51-60 V MPPT window and 60 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
10,011 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
70 A (4 AWG Cu)
CEC Efficiency
92.83%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Altenergy Power System Inc: ELS-114 {208V} Compare Against Peer CEC Listings?

CEC efficiency rank (#2,329), 51-60 V MPPT tracking, and panel fit for Altenergy Power System Inc: ELS-114 {208V}.

Altenergy Power System Inc: ELS-114 {208V} from Altenergy Power System Inc outputs 48.1 A continuous AC at 208 V, commercial single-phase (10,011 W AC, rank #884). Paired with 4 AWG Cu conductors and a 70 A OCPD, its 92.83% CEC efficiency compares closely with Delta Electronics: S12_BDI {208V} (10,057 W). Keep NEC 690.7 winter string Voc below 60 V DC.

Where Does Altenergy Power System Inc: ELS-114 {208V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Altenergy Power System Inc: ELS-114 {208V} at 10,011 W continuous AC output. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Altenergy Power System Inc: ELS-114 {208V} (10,011 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACAltenergy Power Sy: 10,011 W

What Dataset Percentiles Define Altenergy Power System Inc: ELS-114 {208V}?

Dataset percentiles comparing Altenergy Power System Inc: ELS-114 {208V} against 2,343 certified grid-support inverters nationwide. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Altenergy Power System Inc: ELS-114 {208V} Technical ThresholdsPercentile comparison for Altenergy Power System Inc: ELS-114 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output10,011 WCEC Efficiency92.83%Backfeed Breaker70 A

What Do the Dataset Ranks Show for Altenergy Power System Inc: ELS-114 {208V}?

Engineering highlights for Altenergy Power System Inc: ELS-114 {208V} covering efficiency, 4 AWG Cu feeder, and panel compatibility.

Eff #2,329 / 2,343

92.83% CEC Weighted Efficiency

-3.58 pts vs the 96.41% 208 V median; overall power rank #884 (10,011 W, top 37.8%; higher than 62.2% of peers).

NEC 705.12 Check

70 A Required Backfeed OCPD

125% x 48.1 A = 60.1 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

51 V - 60 V (Max 60 V DC)

Tracking span of 9.0 V; listed since 2025-01-13 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 10011.0W / 208 V -> 48.1 A | Breaker >= 1.25 * 48.1 = 60.1 A -> 70 A

CEC Inverters.csv for Altenergy Power System Inc: ELS-114 {208V}: Paco=10011.0 W, Vac=208 V, Vdcmax=60.0 V, Eff=92.83%.

Result: Min 70 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Altenergy Power System Inc: ELS-114 {208V}?

California Energy Commission Solar Equipment List parameters for Altenergy Power System Inc: ELS-114 {208V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Altenergy Power System Inc: ELS-114 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 10,011 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 60 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 51 V - 60 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 192.573 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 92.83% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-01-13 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Altenergy Power System Inc: ELS-114 {208V} (208 V, commercial single-phase)?

Panelboard and switchgear backfeed allowances for Altenergy Power System Inc: ELS-114 {208V} (70 A OCPD). Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Evaluates Altenergy Power System Inc: ELS-114 {208V} (70 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 70 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 70 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 70 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 70 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 70 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Altenergy Power System Inc: ELS-114 {208V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Altenergy Power System Inc: ELS-114 {208V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 51.0-60.0 V MPPT and 60.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 1 panel (micro/module) 0.59 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW

Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: ELS-114 {208V}?

Four alternative CEC inverters matched to Altenergy Power System Inc: ELS-114 {208V} (10,011 W AC), led by Delta Electronics: S12_BDI {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: S12_BDI {208V}
Delta Electronics
10,057 W +46 W 208.0 V 480.0 V 96.7%
Chint Power Systems America: CPS ECH96KTL/US {208V}
Chint Power Systems America
9,550 W -461 W 208.0 V 480.0 V 96.73%
EG4 Electronics LLC: 18KPV-12LV {208V}
EG4 Electronics LLC
10,499 W +488 W 208.0 V 480.0 V 96.07%
EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V}
EG4 Electronics LLC
11,325 W +1314 W 208.0 V 440.0 V 96.79%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: ELS-114 {208V}?

Check Altenergy Power System Inc: ELS-114 {208V} (10,011 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 60 V DC on Altenergy Power System Inc: ELS-114 {208V}.

Altenergy Power System Inc: ELS-114 {208V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (48.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (92.83%) and MPPT window (51-60 V) directly against Delta Electronics: S12_BDI {208V} (10,057 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Altenergy Power System Inc: ELS-114 {208V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Altenergy Power System Inc: ELS-114 {208V} require?

At 10,011 W continuous AC (208 V, commercial single-phase), continuous current is 48.1 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Altenergy Power System Inc: ELS-114 {208V} require?

At 10,011 W AC and 208 V, commercial single-phase, continuous line current is 48.1 A, requiring a 70 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Altenergy Power System Inc: ELS-114 {208V} compare to Delta Electronics: S12_BDI {208V}?

Altenergy Power System Inc: ELS-114 {208V} delivers 10,011 W AC at 92.83% CEC efficiency with a 60 V DC ceiling, while Delta Electronics: S12_BDI {208V} outputs 10,057 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.