Altenergy Power System Inc: ELS-114 {208V} outputs 10,011 W AC at 208 V, commercial single-phase (48.1 A continuous, 70 A OCPD), ranking #2,329 of 2,343 CEC inverters at 92.83% efficiency with a 51-60 V MPPT window and 60 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 10,011 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 70 A (4 AWG Cu)
- CEC Efficiency
- 92.83%
How Does Altenergy Power System Inc: ELS-114 {208V} Compare Against Peer CEC Listings?
CEC efficiency rank (#2,329), 51-60 V MPPT tracking, and panel fit for Altenergy Power System Inc: ELS-114 {208V}.
Altenergy Power System Inc: ELS-114 {208V} from Altenergy Power System Inc outputs 48.1 A continuous AC at 208 V, commercial single-phase (10,011 W AC, rank #884). Paired with 4 AWG Cu conductors and a 70 A OCPD, its 92.83% CEC efficiency compares closely with Delta Electronics: S12_BDI {208V} (10,057 W). Keep NEC 690.7 winter string Voc below 60 V DC.
Where Does Altenergy Power System Inc: ELS-114 {208V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Altenergy Power System Inc: ELS-114 {208V} at 10,011 W continuous AC output. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define Altenergy Power System Inc: ELS-114 {208V}?
Dataset percentiles comparing Altenergy Power System Inc: ELS-114 {208V} against 2,343 certified grid-support inverters nationwide. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Do the Dataset Ranks Show for Altenergy Power System Inc: ELS-114 {208V}?
Engineering highlights for Altenergy Power System Inc: ELS-114 {208V} covering efficiency, 4 AWG Cu feeder, and panel compatibility.
92.83% CEC Weighted Efficiency
-3.58 pts vs the 96.41% 208 V median; overall power rank #884 (10,011 W, top 37.8%; higher than 62.2% of peers).
70 A Required Backfeed OCPD
125% x 48.1 A = 60.1 A -> 70 A standard OCPD using 4 AWG Cu (75 C).
51 V - 60 V (Max 60 V DC)
Tracking span of 9.0 V; listed since 2025-01-13 (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 10011.0W / 208 V -> 48.1 A | Breaker >= 1.25 * 48.1 = 60.1 A -> 70 A
CEC Inverters.csv for Altenergy Power System Inc: ELS-114 {208V}: Paco=10011.0 W, Vac=208 V, Vdcmax=60.0 V, Eff=92.83%.
Result: Min 70 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Altenergy Power System Inc: ELS-114 {208V}?
California Energy Commission Solar Equipment List parameters for Altenergy Power System Inc: ELS-114 {208V} (grid-tied PV inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 10,011 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 60 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 51 V - 60 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 192.573 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 92.83% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2025-01-13 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Altenergy Power System Inc: ELS-114 {208V} (208 V, commercial single-phase)?
Panelboard and switchgear backfeed allowances for Altenergy Power System Inc: ELS-114 {208V} (70 A OCPD). Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 70 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (208V) | 80 A | 70 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 70 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 70 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 70 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Altenergy Power System Inc: ELS-114 {208V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Altenergy Power System Inc: ELS-114 {208V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 1 panel (micro/module) | 0.59 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: ELS-114 {208V}?
Four alternative CEC inverters matched to Altenergy Power System Inc: ELS-114 {208V} (10,011 W AC), led by Delta Electronics: S12_BDI {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: S12_BDI {208V} Delta Electronics |
10,057 W | +46 W | 208.0 V | 480.0 V | 96.7% |
| Chint Power Systems America: CPS ECH96KTL/US {208V} Chint Power Systems America |
9,550 W | -461 W | 208.0 V | 480.0 V | 96.73% |
| EG4 Electronics LLC: 18KPV-12LV {208V} EG4 Electronics LLC |
10,499 W | +488 W | 208.0 V | 480.0 V | 96.07% |
| EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V} EG4 Electronics LLC |
11,325 W | +1314 W | 208.0 V | 440.0 V | 96.79% |
What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: ELS-114 {208V}?
Check Altenergy Power System Inc: ELS-114 {208V} (10,011 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 60 V DC on Altenergy Power System Inc: ELS-114 {208V}.
Altenergy Power System Inc: ELS-114 {208V} Panel & Wire Spec
Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (48.1 A continuous).
Alternative Inverter Comparison
Compare efficiency (92.83%) and MPPT window (51-60 V) directly against Delta Electronics: S12_BDI {208V} (10,057 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Altenergy Power System Inc: ELS-114 {208V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does Altenergy Power System Inc: ELS-114 {208V} require?
At 10,011 W continuous AC (208 V, commercial single-phase), continuous current is 48.1 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Altenergy Power System Inc: ELS-114 {208V} require?
At 10,011 W AC and 208 V, commercial single-phase, continuous line current is 48.1 A, requiring a 70 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Altenergy Power System Inc: ELS-114 {208V} compare to Delta Electronics: S12_BDI {208V}?
Altenergy Power System Inc: ELS-114 {208V} delivers 10,011 W AC at 92.83% CEC efficiency with a 60 V DC ceiling, while Delta Electronics: S12_BDI {208V} outputs 10,057 W at 208 V, commercial single-phase.