DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} outputs 582,490 W AC at 350 V, 3-phase (960.9 A continuous, 1,250 A OCPD), ranking #699 of 2,343 CEC inverters at 97.27% efficiency with a 530-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 582,490 W
- AC Voltage
- 350 V, 3-phase
- Min PV Breaker
- 1,250 A (parallel Cu feeders)
- CEC Efficiency
- 97.27%
How Does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 350 V, 3-phase grid-support overview for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V}.
Rated at 582,490 W AC (960.9 A continuous), DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} ranks #699 of 2,343 CEC units at 97.27% efficiency (-0.19 pts vs the 97.46% 350 V median). Minimum 75 C copper conductor sizing for its 1,250 A circuit is parallel Cu feeders per NEC Table 310.16. Cold-weather string Voc must remain under 1,500 V DC at record local winter lows.
Where Does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} Fall Across Listed CEC Models?
Marks DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} (582,490 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V}?
Benchmarks DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} continuous AC output, 97.27% CEC weighted efficiency, and 1,250 A OCPD breaker demand.
What Do the Dataset Ranks Show for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V}?
Four key NEC 705.12 and California Energy Commission metrics defining DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} by DYNAPOWER COMPANY LLC.
97.27% CEC Weighted Efficiency
-0.19 pts vs the 97.46% 350 V median; overall power rank #188 (582,490 W, top 8.0%; higher than 92.0% of peers).
1,250 A Required Backfeed OCPD
125% x 960.9 A = 1201.1 A -> 1,250 A standard OCPD using parallel Cu feeders (75 C).
530 V - 1,500 V (Max 1,500 V DC)
Tracking span of 970.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 350 V, 3-phase switchgear (200A Bus / 200A Main (350V) to 1,200A Bus / 1,200A Main (350V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 582490.0W / 350 V 3-phase -> 960.9 A | Breaker >= 1.25 * 960.9 = 1201.1 A -> 1,250 A
CEC Inverters.csv for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V}: Paco=582490.0 W, Vac=350 V, Vdcmax=1500.0 V, Eff=97.27%.
Result: Min 1,250 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (350V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 582,490 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 350 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 530 V - 1,500 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 598.834 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.27% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} (350 V, 3-phase)?
Evaluates DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} (1,250 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (350V) | 40 A | 1,250 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (350V) | 80 A | 1,250 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (350V) | 120 A | 1,250 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (350V) | 160 A | 1,250 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (350V) | 240 A | 1,250 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V}?
Sample PV string lengths aligned within 530-1,500 V MPPT and 1,500 V DC max at -10 C. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 13 to 26 panels | 15.34 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 16 to 35 panels | 15.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 16 to 33 panels | 14.03 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 19 to 36 panels | 7.2 kW |
Which Competing Grid-Support Inverters Compare to DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V}?
Competing CEC grid-support inverters near 582,490 W AC and 350 V, 3-phase, led by EPC Power Corp: 50-200100 {720V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| EPC Power Corp: 50-200100 {720V} EPC Power Corp |
561,806 W | -20684 W | 720.0 V | 1500.0 V | 98.58% |
| ABB: PVS-175-TL-POWER-MODULE-1-US {800V} ABB |
179,574 W | -402916 W | 800.0 V | 1200.0 V | 97.39% |
| LS Energy Solutions LLC: PBE-6140-R61-1A0-1000 {600V} LS Energy Solutions LLC |
139,449 W | -443041 W | 600.0 V | 1350.0 V | 98.27% |
| JingTsing Technology Ltd: JTES-PCS125K-1000/480-L03C1 {480V} JingTsing Technology Ltd |
127,819 W | -454671 W | 480.0 V | 950.0 V | 98.0% |
What Are the Interconnection Limits and Best-Fit Uses for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V}?
Check DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} (582,490 W AC, 1,250 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 350 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (350V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V}.
DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 1,250 A OCPD breaker (960.9 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.27%) and MPPT window (530-1,500 V) directly against EPC Power Corp: 50-200100 {720V} (561,806 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} by DYNAPOWER COMPANY LLC covering breaker sizing, MPPT limits, and 350 V, 3-phase interconnection.
What breaker and wire size does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} require?
At 582,490 W continuous AC (350 V, 3-phase), continuous current is 960.9 A; 125% NEC 690.8/705.12 sizing requires a 1,250 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} require?
At 582,490 W AC and 350 V, 3-phase, continuous line current is 960.9 A, requiring a 1,250 A OCPD and 1,200A Bus / 1,200A Main (350V) or NEC 705.11 interconnection.
How does DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} compare to EPC Power Corp: 50-200100 {720V}?
DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V} delivers 582,490 W AC at 97.27% CEC efficiency with a 1,500 V DC ceiling, while EPC Power Corp: 50-200100 {720V} outputs 561,806 W at 350 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)