ABB: PVI-5000-OUTD-US-A {208V} — CEC Inverter Specifications

Manufacturer: ABB Registry: CEC Verified Engineering Specification

ABB: PVI-5000-OUTD-US-A {208V} outputs 5,000 W AC at 208 V, commercial single-phase (24.0 A continuous, 30 A OCPD), ranking #1,958 of 2,343 CEC inverters at 96.0% efficiency with a 100-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
5,000 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
30 A (10 AWG Cu)
CEC Efficiency
96.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ABB: PVI-5000-OUTD-US-A {208V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 208 V, commercial single-phase grid-support overview for ABB: PVI-5000-OUTD-US-A {208V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rated at 5,000 W AC (24.0 A continuous), ABB: PVI-5000-OUTD-US-A {208V} ranks #1,958 of 2,343 CEC units at 96.0% efficiency (-0.41 pts vs the 96.41% 208 V median). Minimum 75 C copper conductor sizing for its 30 A circuit is 10 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 480 V DC at record local winter lows.

Where Does ABB: PVI-5000-OUTD-US-A {208V} Fall Across Listed CEC Models?

Marks ABB: PVI-5000-OUTD-US-A {208V} (5,000 W AC) across the California Energy Commission inverter AC capacity distribution. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where ABB: PVI-5000-OUTD-US-A {208V} (5,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACABB: PVI-5000-OUTD: 5,000 W

What Dataset Percentiles Define ABB: PVI-5000-OUTD-US-A {208V}?

Benchmarks ABB: PVI-5000-OUTD-US-A {208V} continuous AC output, 96.0% CEC weighted efficiency, and 30 A OCPD breaker demand. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

ABB: PVI-5000-OUTD-US-A {208V} Technical ThresholdsPercentile comparison for ABB: PVI-5000-OUTD-US-A {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output5,000 WCEC Efficiency96.0%Backfeed Breaker30 A

What Do the Dataset Ranks Show for ABB: PVI-5000-OUTD-US-A {208V}?

Four key NEC 705.12 and California Energy Commission metrics defining ABB: PVI-5000-OUTD-US-A {208V} by ABB. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Eff #1,958 / 2,343

96.0% CEC Weighted Efficiency

-0.41 pts vs the 96.41% 208 V median; overall power rank #1,516 (5,000 W, below CEC median; higher than 33.9% of peers).

NEC 705.12 Check

30 A Required Backfeed OCPD

125% x 24.0 A = 30.0 A -> 30 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

100 V - 480 V (Max 480 V DC)

Tracking span of 380.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5000.0W / 208 V -> 24.0 A | Breaker >= 1.25 * 24.0 = 30.0 A -> 30 A

CEC Inverters.csv for ABB: PVI-5000-OUTD-US-A {208V}: Paco=5000.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=96.0%.

Result: Min 30 A breaker & 10 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for ABB: PVI-5000-OUTD-US-A {208V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for ABB: PVI-5000-OUTD-US-A {208V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for ABB: PVI-5000-OUTD-US-A {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 5,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 100 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 16.8013 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.0% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to ABB: PVI-5000-OUTD-US-A {208V} (208 V, commercial single-phase)?

Evaluates ABB: PVI-5000-OUTD-US-A {208V} (30 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates ABB: PVI-5000-OUTD-US-A {208V} (30 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 30 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 30 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 30 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 30 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 30 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With ABB: PVI-5000-OUTD-US-A {208V}?

Sample PV string lengths aligned within 100-480 V MPPT and 480 V DC max at -10 C. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sampled CEC PV modules aligned within 100.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 3 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 3 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 3 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 4 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to ABB: PVI-5000-OUTD-US-A {208V}?

Competing CEC grid-support inverters near 5,000 W AC and 208 V, commercial single-phase, led by Delta Electronics: E6-TL-US(AC) {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: E6-TL-US(AC) {208V}
Delta Electronics
5,000 W Tie (0 W) 208.0 V 480.0 V 97.6%
Delta Electronics: E6-TL-US {208V}
Delta Electronics
4,992 W -8 W 208.0 V 480.0 V 97.13%
Delta Electronics: M6-TL-US {208V}
Delta Electronics
4,990 W -10 W 208.0 V 480.0 V 97.13%
Delta Electronics: E6_BDI {208V}
Delta Electronics
5,025 W +25 W 208.0 V 480.0 V 97.13%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for ABB: PVI-5000-OUTD-US-A {208V}?

Check ABB: PVI-5000-OUTD-US-A {208V} (5,000 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on ABB: PVI-5000-OUTD-US-A {208V}.

ABB: PVI-5000-OUTD-US-A {208V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (24.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.0%) and MPPT window (100-480 V) directly against Delta Electronics: E6-TL-US(AC) {208V} (5,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for ABB: PVI-5000-OUTD-US-A {208V} by ABB covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does ABB: PVI-5000-OUTD-US-A {208V} require?

At 5,000 W continuous AC (208 V, commercial single-phase), continuous current is 24.0 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does ABB: PVI-5000-OUTD-US-A {208V} require?

At 5,000 W AC and 208 V, commercial single-phase, continuous line current is 24.0 A, requiring a 30 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does ABB: PVI-5000-OUTD-US-A {208V} compare to Delta Electronics: E6-TL-US(AC) {208V}?

ABB: PVI-5000-OUTD-US-A {208V} delivers 5,000 W AC at 96.0% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: E6-TL-US(AC) {208V} outputs 5,000 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?