Delta Electronics: E6_BDI {208V} outputs 5,025 W AC at 208 V, commercial single-phase (24.2 A continuous, 35 A OCPD), ranking #856 of 2,343 CEC inverters at 97.13% efficiency with a 280-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 5,025 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 35 A (8 AWG Cu)
- CEC Efficiency
- 97.13%
How Does Delta Electronics: E6_BDI {208V} Compare Against Peer CEC Listings?
CEC efficiency rank (#856), 280-480 V MPPT tracking, and panel fit for Delta Electronics: E6_BDI {208V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Operating at 208 V, commercial single-phase, Delta Electronics: E6_BDI {208V} converts DC array energy at 97.13% CEC weighted efficiency (top 37.0%; higher than 63.0% of peers) with a 480 V max DC input and 13.6146 A max input current for NEC 690.7 string safety. Compare this 5,025 W hybrid battery-capable inverter directly with ABB: PVI-5000-OUTD-US-A {208V} (5,000 W). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
Where Does Delta Electronics: E6_BDI {208V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Delta Electronics: E6_BDI {208V} at 5,025 W continuous AC output. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Delta Electronics: E6_BDI {208V}?
Dataset percentiles comparing Delta Electronics: E6_BDI {208V} against 2,343 certified grid-support inverters nationwide. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Do the Dataset Ranks Show for Delta Electronics: E6_BDI {208V}?
Engineering highlights for Delta Electronics: E6_BDI {208V} covering efficiency, 8 AWG Cu feeder, and panel compatibility. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
97.13% CEC Weighted Efficiency
+0.72 pts vs the 96.41% 208 V median; overall power rank #1,496 (5,025 W, below CEC median; higher than 36.2% of peers).
35 A Required Backfeed OCPD
125% x 24.2 A = 30.2 A -> 35 A standard OCPD using 8 AWG Cu (75 C).
280 V - 480 V (Max 480 V DC)
Tracking span of 200.0 V; listed since 2024-04-02 (hybrid battery-capable inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 5025.0W / 208 V -> 24.2 A | Breaker >= 1.25 * 24.2 = 30.2 A -> 35 A
CEC Inverters.csv for Delta Electronics: E6_BDI {208V}: Paco=5025.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=97.13%.
Result: Min 35 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Delta Electronics: E6_BDI {208V}?
California Energy Commission Solar Equipment List parameters for Delta Electronics: E6_BDI {208V} (hybrid battery-capable inverter) interconnection. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 5,025 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 280 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 13.6146 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.13% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2024-04-02 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Delta Electronics: E6_BDI {208V} (208 V, commercial single-phase)?
Panelboard and switchgear backfeed allowances for Delta Electronics: E6_BDI {208V} (35 A OCPD). Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 35 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (208V) | 80 A | 35 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 35 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 35 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 35 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Delta Electronics: E6_BDI {208V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Delta Electronics: E6_BDI {208V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 9 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 9 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 10 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Delta Electronics: E6_BDI {208V}?
Four alternative CEC inverters matched to Delta Electronics: E6_BDI {208V} (5,025 W AC), led by ABB: PVI-5000-OUTD-US-A {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| ABB: PVI-5000-OUTD-US-A {208V} ABB |
5,000 W | -25 W | 208.0 V | 480.0 V | 96.0% |
| ABB: PVI-5000-OUTD-US-Z-A {208V} ABB |
5,000 W | -25 W | 208.0 V | 480.0 V | 96.0% |
| ABB: PVI-5000-OUTD-US-Z-M-A {208V} ABB |
5,000 W | -25 W | 208.0 V | 480.0 V | 96.0% |
| ABB: UNO-DM-50-TL-PLUS-US-SB-RA {208V} ABB |
4,600 W | -425 W | 208.0 V | 480.0 V | 96.31% |
What Are the Interconnection Limits and Best-Fit Uses for Delta Electronics: E6_BDI {208V}?
Check Delta Electronics: E6_BDI {208V} (5,025 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Delta Electronics: E6_BDI {208V}.
Delta Electronics: E6_BDI {208V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (24.2 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.13%) and MPPT window (280-480 V) directly against ABB: PVI-5000-OUTD-US-A {208V} (5,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Delta Electronics: E6_BDI {208V} by Delta Electronics covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does Delta Electronics: E6_BDI {208V} require?
At 5,025 W continuous AC (208 V, commercial single-phase), continuous current is 24.2 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Delta Electronics: E6_BDI {208V} require?
At 5,025 W AC and 208 V, commercial single-phase, continuous line current is 24.2 A, requiring a 35 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Delta Electronics: E6_BDI {208V} compare to ABB: PVI-5000-OUTD-US-A {208V}?
Delta Electronics: E6_BDI {208V} delivers 5,025 W AC at 97.13% CEC efficiency with a 480 V DC ceiling, while ABB: PVI-5000-OUTD-US-A {208V} outputs 5,000 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)