ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P is a 240.0 W STC (214.9 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.73% efficiency, 37.5 V Voc at 25 C, and 41.92 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 240.0 W
- PTC Wattage
- 214.9 W
- Voc @ 25C
- 37.5 V
- Efficiency
- 14.73%
How Does ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P Compare Against Peer CEC Listings?
Solar engineering breakdown for ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from ZNSHINE PV-TECH Co Ltd and peers, ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P stands 170.0 W below the 410.0 W Mono-c-Si median and typical 89.5% PTC-to-STC thermal output (214.9 W real-world rating). Sizing 6 kW (25 panels) to 10 kW (42 panels) yields $1,502-$2,523/yr in baseline US bill offset. Lower 37.5 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P Fall Across Listed CEC Models?
Distribution marker showing ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P (240.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P?
Dataset percentiles tracking ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P?
Benchmark highlights for ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
240.0 W STC · Higher Than 6.1%
240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.73% Aperture Efficiency
Power density 147.3 W/m2 (5.18 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.92 V at -10 C (586.9 V string) and 43.19 V at -20 C (13 max).
34 Panels = 8,160 W STC
Occupies 55.4 m2 (596 sq ft) producing 7,307 W PTC; NEC 690.8 OCPD floor is 13.14 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.5 * (1 + (-0.337/100) * (-10 - 25)) = 41.92 V | OCPD = 1.56 * 8.42 = 13.14 A
Inputs from CEC Modules.csv for ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P: Voc=37.5 V, beta_Voc=-0.337%/C, Isc=8.42 A, STC=240.0 W, Area=1.629 m2.
Result: 14 panels max on 600 V (586.9 V); 34 panels for 8 kW (596 sq ft).
What Are the Published CEC Specifications for ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P?
Official CEC datasheet figures for ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 214.9 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.42 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.74 V / 8.07 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.337 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.73% (1.629 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.0 kW | 438 sq ft | $1,502 | $2,539 |
| 8 kW Class | 34 | 8.16 kW | 596 sq ft | $2,042 | $3,454 |
| 10 kW Class | 42 | 10.08 kW | 736 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This ZNSHINE PV-TECH Co Ltd Series?
Consolidated ZNSHINE PV-TECH Co Ltd wattage variants sharing the ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| ZNSHINE PV-TECH Co Ltd ZXP6-D60-235/P | 235.0 W | 210.3 W | 37.33 V | 29.55 V | 14.43% |
| ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P | 240.0 W | 214.9 W | 37.5 V | 29.74 V | 14.73% |
| ZNSHINE PV-TECH Co Ltd ZXP6-D60-245/P | 245.0 W | 219.5 W | 37.64 V | 29.95 V | 15.04% |
How Many ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P (41.92 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.19 V | 13 panels | 561.5 V | 23 panels |
| -10 C (14 F) | 41.92 V | 14 panels | 586.9 V | 23 panels |
| 0 C (32 F) | 40.66 V | 14 panels | 569.2 V | 24 panels |
| 25 C (77 F STC) | 37.5 V | 16 panels | 600.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P?
Competing CEC solar panels closest to ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P in nameplate wattage and Voc, starting with AXITEC AC-240M/156-60S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-240M/156-60S AXITEC |
240.0 W | Tie (0 W) | 37.47 V | 14.79% | 90.4% |
| Heliene 60P240 Heliene |
240.0 W | Tie (0 W) | 37.55 V | 14.62% | 89.2% |
| AXITEC AC-240P/156-60B AXITEC |
240.0 W | Tie (0 W) | 37.4 V | 14.79% | 89.5% |
| Centrosolar America EP6 240 BW Centrosolar America |
240.0 W | Tie (0 W) | 37.64 V | 14.68% | 88.6% |
What Are the Design Limits and Best-Fit Uses for ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P?
Evaluate ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P (240.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P reaches 43.19 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 596 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (596 sq ft).
- 2026 tax credit baseline: cash residential installs of ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P 8 kW Residential Fit
Needs 34 modules (596 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-240M/156-60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 214.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P by ZNSHINE PV-TECH Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P?
Multiplying ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P's 8.42 A short-circuit current by 1.56 equals 13.14 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.92 V cold Voc at 14 F and handles 8.42 A Isc; string inverters cap ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P at 14 panels on 600 V.
Is ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)