Skip to main content
WireAndSun
Calculators
CEC PV Module

ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N — CEC Solar Module Specifications

Manufacturer: ZNSHINE PV-TECH Co Ltd Registry: CEC Verified Engineering Specification

ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N is a 695.0 W STC (664.1 W PTC) Mono-c-Si solar module ranking #226 of 21,677 CEC listings (top 1.1%; higher than 98.9% of peers). It delivers 22.42% efficiency, 48.1 V Voc at 25 C, and 51.89 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
695.0 W
PTC Wattage
664.1 W
Voc @ 25C
48.1 V
Efficiency
22.42%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N Compare Against Peer CEC Listings?

How ZNSHINE PV-TECH Co Ltd ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N handles rooftop heat (664.1 W PTC), 8 kW sizing, and cold winter string voltage.

ZNSHINE PV-TECH Co Ltd builds the ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N (Mono-c-Si) as a large-format commercial and ground-mount module delivering 224.2 W/m2 (2.51 percentage points above 19.91% CEC median). Compared against Nuuko Solar GmbH NKM695N-132BDG12 (695.0 W), this model holds strong 95.6% PTC-to-STC heat retention (#87 of 21,677). Higher 48.1 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 28.44 A overcurrent floor served by a 30 A breaker.

Where Does ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N Fall Across Listed CEC Models?

Where ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N (695.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N (695.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZNSHINE PV-TECH Co: 695.0 W

What Dataset Percentiles Define ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N?

Percentile placement of ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N across power density (224.2 W/m2), thermal retention, and nameplate STC wattage.

ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N Engineering BenchmarksPercentile comparison of ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage695.0 WPTC/STC Retention95.6%Module Efficiency22.42%

What Do the Dataset Ranks Show for ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N?

Four critical engineering numbers homeowners and solar installers check first when reviewing ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N specifications.

Rank #226 / 21,677

Top 1.1% STC Output

695.0 W STC (+310.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,175

22.42% Aperture Efficiency

Power density 224.2 W/m2 (2.51 percentage points above 19.91% CEC median). PTC/STC ratio: 95.6% (rank #87).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.89 V at -10 C (570.8 V string) and 52.97 V at -20 C (11 max).

8 kW Reference Array

12 Panels = 8,340 W STC

Occupies 37.2 m2 (400 sq ft) producing 7,969 W PTC; NEC 690.8 OCPD floor is 28.44 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.1 * (1 + (-0.225/100) * (-10 - 25)) = 51.89 V | OCPD = 1.56 * 18.23 = 28.44 A

Inputs from CEC Modules.csv for ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N: Voc=48.1 V, beta_Voc=-0.225%/C, Isc=18.23 A, STC=695.0 W, Area=3.1 m2.

Result: 11 panels max on 600 V (570.8 V); 12 panels for 8 kW (400 sq ft).

What Are the Published CEC Specifications for ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N.

Official California Energy Commission (NREL SAM) test parameters for ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 695.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 664.1 W (95.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 18.23 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.3 V / 17.25 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.225 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.42% (3.1 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N (695.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 9 6.25 kW 300 sq ft $1,564 $2,645
8 kW Class 12 8.34 kW 400 sq ft $2,087 $3,530
10 kW Class 15 10.43 kW 501 sq ft $2,611 $4,414

How Many ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N Modules Fit in a Cold-Weather String?

Maximum series module counts for ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.1V and beta_Voc=-0.225%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.97 V 11 panels 582.7 V 18 panels
-10 C (14 F) 51.89 V 11 panels 570.8 V 19 panels
0 C (32 F) 50.81 V 11 panels 558.9 V 19 panels
25 C (77 F STC) 48.1 V 12 panels 577.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N?

Alternative CEC solar modules from competing brands near ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N (695.0 W), including Nuuko Solar GmbH NKM695N-132BDG12.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Nuuko Solar GmbH NKM695N-132BDG12
Nuuko Solar GmbH
695.0 W Tie (0 W) 48.24 V 22.35% 94.2%
Thornova Solar TS-BGT66(695)-G12
Thornova Solar
695.0 W Tie (0 W) 48.3 V 22.56% 95.1%
SEG Solar Inc SEG-695-BTC-BG
SEG Solar Inc
695.0 W Tie (0 W) 47.7 V 22.56% 94.5%
Boviet Solar Technology Co Ltd BVM8611M-690-H-HC-BF
Boviet Solar Technology Co Ltd
690.0 W -5.0 W 48.25 V 23.71% 95.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N?

Evaluate ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N (695.0 W STC, 48.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N reaches 52.97 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 12 panels for an 8 kW build require 400 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N 8 kW Residential Fit

Needs 12 modules (400 sq ft) with a 30 A string OCPD, offsetting ~$2,087/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Nuuko Solar GmbH NKM695N-132BDG12.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 664.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N by ZNSHINE PV-TECH Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N?

Multiplying ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N's 18.23 A short-circuit current by 1.56 equals 28.44 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.

Can ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.89 V cold Voc at 14 F and handles 18.23 A Isc; string inverters cap ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N at 11 panels on 600 V.

Is ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N rely on utility bill offset (~$2,087/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.