Skip to main content
WireAndSun
Calculators
CEC PV Module

Zebra Energy ZBR-290P — CEC Solar Module Specifications

Manufacturer: Zebra Energy Registry: CEC Verified Engineering Specification

Zebra Energy ZBR-290P is a 290.0 W STC (262.3 W PTC) Multi-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.97% efficiency, 44.2 V Voc at 25 C, and 49.99 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
290.0 W
PTC Wattage
262.3 W
Voc @ 25C
44.2 V
Efficiency
14.97%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Zebra Energy ZBR-290P Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Zebra Energy ZBR-290P (Multi-c-Si) residential solar systems.

Zebra Energy ZBR-290P delivers 149.7 W/m2 (4.94 percentage points below 19.91% CEC median) and typical 90.4% PTC-to-STC thermal output (262.3 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (584 sq ft). At -4 F (-20 C), string voltage climbs to 51.64 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Centrosolar America DM72 290 (290.0 W).

Where Does Zebra Energy ZBR-290P Fall Across Listed CEC Models?

Comparison of Zebra Energy ZBR-290P (290.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Zebra Energy ZBR-290P (290.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZebra Energy ZBR-2: 290.0 W

What Dataset Percentiles Define Zebra Energy ZBR-290P?

Relative ranking of Zebra Energy ZBR-290P across nameplate watts, 90.4% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Zebra Energy ZBR-290P Engineering BenchmarksPercentile comparison of Zebra Energy ZBR-290P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage290.0 WPTC/STC Retention90.4%Module Efficiency14.97%

What Do the Dataset Ranks Show for Zebra Energy ZBR-290P?

Summary of Zebra Energy ZBR-290P output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #17,253 / 21,677

290.0 W STC · Higher Than 18.8%

290.0 W STC (-95.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,768

14.97% Aperture Efficiency

Power density 149.7 W/m2 (4.94 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.99 V at -10 C (599.9 V string) and 51.64 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,120 W STC

Occupies 54.2 m2 (584 sq ft) producing 7,344 W PTC; NEC 690.8 OCPD floor is 13.7 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.2 * (1 + (-0.374/100) * (-10 - 25)) = 49.99 V | OCPD = 1.56 * 8.78 = 13.7 A

Inputs from CEC Modules.csv for Zebra Energy ZBR-290P: Voc=44.2 V, beta_Voc=-0.374%/C, Isc=8.78 A, STC=290.0 W, Area=1.937 m2.

Result: 12 panels max on 600 V (599.9 V); 28 panels for 8 kW (584 sq ft).

What Are the Published CEC Specifications for Zebra Energy ZBR-290P?

Complete CEC test sheet for Zebra Energy ZBR-290P including Isc (8.78 A), Voc (44.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Zebra Energy ZBR-290P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 290.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 262.3 W (90.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.78 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.0 V / 8.06 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.374 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.97% (1.937 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Zebra Energy ZBR-290P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Zebra Energy ZBR-290P.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.09 kW 438 sq ft $1,524 $2,577
8 kW Class 28 8.12 kW 584 sq ft $2,032 $3,437
10 kW Class 35 10.15 kW 730 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This Zebra Energy Series?

Related Zebra Energy power steps and black/silver trims consolidated into this Zebra Energy ZBR-290P series guide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Zebra Energy ZBR-290P wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Zebra Energy ZBR-280P 280.0 W 252.2 W 45.29 V 36.48 V 14.45%
Zebra Energy ZBR-285P 285.0 W 257.7 W 43.8 V 35.8 V 14.71%
Zebra Energy ZBR-290P 290.0 W 262.3 W 44.2 V 36.0 V 14.97%
Zebra Energy ZBR-295P 295.0 W 267.0 W 44.3 V 36.1 V 15.23%

How Many Zebra Energy ZBR-290P Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Zebra Energy ZBR-290P (44.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.2V and beta_Voc=-0.374%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.64 V 11 panels 568.0 V 19 panels
-10 C (14 F) 49.99 V 12 panels 599.9 V 20 panels
0 C (32 F) 48.33 V 12 panels 580.0 V 20 panels
25 C (77 F STC) 44.2 V 13 panels 574.6 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Zebra Energy ZBR-290P?

Four comparable CEC modules such as Centrosolar America DM72 290 (290.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM72 290
Centrosolar America
290.0 W Tie (0 W) 44.4 V 14.92% 90.6%
Gintung Energy GTEC-290G6M
Gintung Energy
290.0 W Tie (0 W) 44.61 V 14.83% 89.6%
Gintung Energy GTEC-290G6S
Gintung Energy
290.0 W Tie (0 W) 44.84 V 14.83% 89.7%
AXITEC AC-290M/156-72S
AXITEC
290.0 W Tie (0 W) 44.98 V 14.95% 90.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Zebra Energy ZBR-290P?

Evaluate Zebra Energy ZBR-290P (290.0 W STC, 44.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Zebra Energy ZBR-290P reaches 51.64 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 584 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (584 sq ft).
  • 2026 tax credit baseline: cash residential installs of Zebra Energy ZBR-290P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Zebra Energy ZBR-290P 8 kW Residential Fit

Needs 28 modules (584 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 290.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 262.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Zebra Energy ZBR-290P by Zebra Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Zebra Energy ZBR-290P panels fit on a 600 V winter solar string?

At -10 C (14 F), Zebra Energy ZBR-290P cold Voc rises from 44.2 V to 49.99 V (beta_Voc -0.374%/C), capping a 600 V string at 12 panels (599.9 V).

How much roof area does an 8 kW array of Zebra Energy ZBR-290P need?

An 8 kW DC system uses 28 Zebra Energy ZBR-290P modules (8,120 W STC / 7,344 W PTC), covering roughly 584 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

How does Zebra Energy ZBR-290P compare against Centrosolar America DM72 290?

Zebra Energy ZBR-290P outputs 290.0 W STC (44.2 V Voc, rank #17,253 of 21,677), while Centrosolar America DM72 290 delivers 290.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.