Manufacturer: Zebra Energy Registry: CEC Verified Engineering Specification

Zebra Energy ZBR-260P is a 260.0 W STC (233.8 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 13.42% efficiency, 42.26 V Voc at 25 C, and 48.13 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
233.8 W
Voc @ 25C
42.26 V
Efficiency
13.42%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Zebra Energy ZBR-260P Compare Against Peer CEC Listings?

Solar engineering breakdown for Zebra Energy ZBR-260P: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Measured at 260.0 W STC and 233.8 W PTC, Zebra Energy ZBR-260P sits -125.0 W vs all-CEC median (below all-CEC median; higher than 10.4% of peers) among 21,677 listed modules. Power density reaches 134.2 W/m2 (6.49 percentage points below 19.91% CEC median). Mid-range 42.26 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer Gintung Energy ASEC-260G6M6B rates 260.0 W.

Where Does Zebra Energy ZBR-260P Fall Across Listed CEC Models?

Distribution marker showing Zebra Energy ZBR-260P (260.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Zebra Energy ZBR-260P (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZebra Energy ZBR-2: 260.0 W

What Dataset Percentiles Define Zebra Energy ZBR-260P?

Dataset percentiles tracking Zebra Energy ZBR-260P power output, thermal retention ratio, and aperture efficiency against 21,677 models. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Zebra Energy ZBR-260P Engineering BenchmarksPercentile comparison of Zebra Energy ZBR-260P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention89.9%Module Efficiency13.42%

What Do the Dataset Ranks Show for Zebra Energy ZBR-260P?

Benchmark highlights for Zebra Energy ZBR-260P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,244

13.42% Aperture Efficiency

Power density 134.2 W/m2 (6.49 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.13 V at -10 C (577.6 V string) and 49.81 V at -20 C (12 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 60.0 m2 (646 sq ft) producing 7,248 W PTC; NEC 690.8 OCPD floor is 13.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.26 * (1 + (-0.397/100) * (-10 - 25)) = 48.13 V | OCPD = 1.56 * 8.59 = 13.4 A

Inputs from CEC Modules.csv for Zebra Energy ZBR-260P: Voc=42.26 V, beta_Voc=-0.397%/C, Isc=8.59 A, STC=260.0 W, Area=1.937 m2.

Result: 12 panels max on 600 V (577.6 V); 31 panels for 8 kW (646 sq ft).

What Are the Published CEC Specifications for Zebra Energy ZBR-260P?

Official CEC datasheet figures for Zebra Energy ZBR-260P (Multi-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for Zebra Energy ZBR-260P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 233.8 W (89.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 42.26 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.9 V / 7.45 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.397 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.42% (1.937 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Zebra Energy ZBR-260P Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Zebra Energy ZBR-260P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 500 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 646 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 813 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Zebra Energy Series?

Consolidated Zebra Energy wattage variants sharing the Zebra Energy ZBR-260P mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the Zebra Energy ZBR-260P wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Zebra Energy ZBR-250P 250.0 W 224.6 W 40.9 V 34.6 V 12.9%
Zebra Energy ZBR-260P 260.0 W 233.8 W 42.26 V 34.9 V 13.42%
Zebra Energy ZBR-270P 270.0 W 243.0 W 44.5 V 35.38 V 13.94%

How Many Zebra Energy ZBR-260P Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Zebra Energy ZBR-260P (48.13 V at 14 F).

Computed from Voc=42.26V and beta_Voc=-0.397%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.81 V 12 panels 597.7 V 20 panels
-10 C (14 F) 48.13 V 12 panels 577.6 V 20 panels
0 C (32 F) 46.45 V 12 panels 557.4 V 21 panels
25 C (77 F STC) 42.26 V 14 panels 591.6 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Zebra Energy ZBR-260P?

Competing CEC solar panels closest to Zebra Energy ZBR-260P in nameplate wattage and Voc, starting with Gintung Energy ASEC-260G6M6B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-260G6M6B
Gintung Energy
260.0 W Tie (0 W) 41.21 V 14.66% 87.8%
Anhui Rinengzhongtian Semiconductor Development QJP265-72
Anhui Rinengzhongtian Semiconductor Development
265.0 W +5.0 W 42.3 V 13.66% 89.1%
Gintung Energy ASEC-260G6M
Gintung Energy
260.0 W Tie (0 W) 43.84 V 13.29% 89.3%
BYD Company Limited BYD 265P6C-36
BYD Company Limited
265.0 W +5.0 W 43.11 V 13.66% 90.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Zebra Energy ZBR-260P?

Evaluate Zebra Energy ZBR-260P (260.0 W STC, 42.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Zebra Energy ZBR-260P reaches 49.81 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 646 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (646 sq ft).
  • 2026 tax credit baseline: cash residential installs of Zebra Energy ZBR-260P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Zebra Energy ZBR-260P 8 kW Residential Fit

Needs 31 modules (646 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Gintung Energy ASEC-260G6M6B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 233.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Zebra Energy ZBR-260P by Zebra Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Zebra Energy ZBR-260P panels fit on a 600 V winter solar string?

At -10 C (14 F), Zebra Energy ZBR-260P cold Voc rises from 42.26 V to 48.13 V (beta_Voc -0.397%/C), capping a 600 V string at 12 panels (577.6 V).

How much roof area does an 8 kW array of Zebra Energy ZBR-260P need?

An 8 kW DC system uses 31 Zebra Energy ZBR-260P modules (8,060 W STC / 7,248 W PTC), covering roughly 646 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does Zebra Energy ZBR-260P compare against Gintung Energy ASEC-260G6M6B?

Zebra Energy ZBR-260P outputs 260.0 W STC (42.26 V Voc, rank #19,146 of 21,677), while Gintung Energy ASEC-260G6M6B delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.