Zebra Energy ZBR-260P is a 260.0 W STC (233.8 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 13.42% efficiency, 42.26 V Voc at 25 C, and 48.13 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 233.8 W
- Voc @ 25C
- 42.26 V
- Efficiency
- 13.42%
How Does Zebra Energy ZBR-260P Compare Against Peer CEC Listings?
Solar engineering breakdown for Zebra Energy ZBR-260P: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Measured at 260.0 W STC and 233.8 W PTC, Zebra Energy ZBR-260P sits -125.0 W vs all-CEC median (below all-CEC median; higher than 10.4% of peers) among 21,677 listed modules. Power density reaches 134.2 W/m2 (6.49 percentage points below 19.91% CEC median). Mid-range 42.26 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer Gintung Energy ASEC-260G6M6B rates 260.0 W.
Where Does Zebra Energy ZBR-260P Fall Across Listed CEC Models?
Distribution marker showing Zebra Energy ZBR-260P (260.0 W) relative to the 385.0 W all-CEC solar panel median. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define Zebra Energy ZBR-260P?
Dataset percentiles tracking Zebra Energy ZBR-260P power output, thermal retention ratio, and aperture efficiency against 21,677 models. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for Zebra Energy ZBR-260P?
Benchmark highlights for Zebra Energy ZBR-260P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.42% Aperture Efficiency
Power density 134.2 W/m2 (6.49 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 48.13 V at -10 C (577.6 V string) and 49.81 V at -20 C (12 max).
31 Panels = 8,060 W STC
Occupies 60.0 m2 (646 sq ft) producing 7,248 W PTC; NEC 690.8 OCPD floor is 13.4 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 42.26 * (1 + (-0.397/100) * (-10 - 25)) = 48.13 V | OCPD = 1.56 * 8.59 = 13.4 A
Inputs from CEC Modules.csv for Zebra Energy ZBR-260P: Voc=42.26 V, beta_Voc=-0.397%/C, Isc=8.59 A, STC=260.0 W, Area=1.937 m2.
Result: 12 panels max on 600 V (577.6 V); 31 panels for 8 kW (646 sq ft).
What Are the Published CEC Specifications for Zebra Energy ZBR-260P?
Official CEC datasheet figures for Zebra Energy ZBR-260P (Multi-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 233.8 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 42.26 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.9 V / 7.45 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.397 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.42% (1.937 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Zebra Energy ZBR-260P Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Zebra Energy ZBR-260P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 500 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 646 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 813 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Zebra Energy Series?
Consolidated Zebra Energy wattage variants sharing the Zebra Energy ZBR-260P mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Zebra Energy ZBR-250P | 250.0 W | 224.6 W | 40.9 V | 34.6 V | 12.9% |
| Zebra Energy ZBR-260P | 260.0 W | 233.8 W | 42.26 V | 34.9 V | 13.42% |
| Zebra Energy ZBR-270P | 270.0 W | 243.0 W | 44.5 V | 35.38 V | 13.94% |
How Many Zebra Energy ZBR-260P Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Zebra Energy ZBR-260P (48.13 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 49.81 V | 12 panels | 597.7 V | 20 panels |
| -10 C (14 F) | 48.13 V | 12 panels | 577.6 V | 20 panels |
| 0 C (32 F) | 46.45 V | 12 panels | 557.4 V | 21 panels |
| 25 C (77 F STC) | 42.26 V | 14 panels | 591.6 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Zebra Energy ZBR-260P?
Competing CEC solar panels closest to Zebra Energy ZBR-260P in nameplate wattage and Voc, starting with Gintung Energy ASEC-260G6M6B.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-260G6M6B Gintung Energy |
260.0 W | Tie (0 W) | 41.21 V | 14.66% | 87.8% |
| Anhui Rinengzhongtian Semiconductor Development QJP265-72 Anhui Rinengzhongtian Semiconductor Development |
265.0 W | +5.0 W | 42.3 V | 13.66% | 89.1% |
| Gintung Energy ASEC-260G6M Gintung Energy |
260.0 W | Tie (0 W) | 43.84 V | 13.29% | 89.3% |
| BYD Company Limited BYD 265P6C-36 BYD Company Limited |
265.0 W | +5.0 W | 43.11 V | 13.66% | 90.9% |
What Are the Design Limits and Best-Fit Uses for Zebra Energy ZBR-260P?
Evaluate Zebra Energy ZBR-260P (260.0 W STC, 42.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Zebra Energy ZBR-260P reaches 49.81 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 646 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (646 sq ft).
- 2026 tax credit baseline: cash residential installs of Zebra Energy ZBR-260P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Zebra Energy ZBR-260P 8 kW Residential Fit
Needs 31 modules (646 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Gintung Energy ASEC-260G6M6B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 233.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Zebra Energy ZBR-260P by Zebra Energy grounded in CEC test data and NEC 690.7/690.8 limits.
How many Zebra Energy ZBR-260P panels fit on a 600 V winter solar string?
At -10 C (14 F), Zebra Energy ZBR-260P cold Voc rises from 42.26 V to 48.13 V (beta_Voc -0.397%/C), capping a 600 V string at 12 panels (577.6 V).
How much roof area does an 8 kW array of Zebra Energy ZBR-260P need?
An 8 kW DC system uses 31 Zebra Energy ZBR-260P modules (8,060 W STC / 7,248 W PTC), covering roughly 646 sq ft and saving ~$2,017/yr at 18.54 c/kWh.
How does Zebra Energy ZBR-260P compare against Gintung Energy ASEC-260G6M6B?
Zebra Energy ZBR-260P outputs 260.0 W STC (42.26 V Voc, rank #19,146 of 21,677), while Gintung Energy ASEC-260G6M6B delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)