Zebra Energy ZBR-240PA — CEC Solar Module Specifications

Manufacturer: Zebra Energy Registry: CEC Verified Engineering Specification

Zebra Energy ZBR-240PA is a 240.0 W STC (216.8 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.69% efficiency, 36.2 V Voc at 25 C, and 40.99 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
240.0 W
PTC Wattage
216.8 W
Voc @ 25C
36.2 V
Efficiency
14.69%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Zebra Energy ZBR-240PA Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Zebra Energy ZBR-240PA (Multi-c-Si) residential solar systems.

Homeowners evaluating Zebra Energy ZBR-240PA need 25 panels for 6 kW or 34 panels (598 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (598 sq ft). Under NEC 690.7(A), beta_Voc (-0.378%/C) pushes open-circuit voltage to 40.99 V at 14 F and 42.36 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Zebra Energy ZBR-240PA Fall Across Listed CEC Models?

Comparison of Zebra Energy ZBR-240PA (240.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Zebra Energy ZBR-240PA (240.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZebra Energy ZBR-2: 240.0 W

What Dataset Percentiles Define Zebra Energy ZBR-240PA?

Relative ranking of Zebra Energy ZBR-240PA across nameplate watts, 90.3% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Zebra Energy ZBR-240PA Engineering BenchmarksPercentile comparison of Zebra Energy ZBR-240PA wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage240.0 WPTC/STC Retention90.3%Module Efficiency14.69%

What Do the Dataset Ranks Show for Zebra Energy ZBR-240PA?

Summary of Zebra Energy ZBR-240PA output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.

Rank #20,160 / 21,677

240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,164

14.69% Aperture Efficiency

Power density 147.0 W/m2 (5.22 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.99 V at -10 C (573.9 V string) and 42.36 V at -20 C (14 max).

8 kW Reference Array

34 Panels = 8,160 W STC

Occupies 55.5 m2 (598 sq ft) producing 7,371 W PTC; NEC 690.8 OCPD floor is 13.85 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.2 * (1 + (-0.378/100) * (-10 - 25)) = 40.99 V | OCPD = 1.56 * 8.88 = 13.85 A

Inputs from CEC Modules.csv for Zebra Energy ZBR-240PA: Voc=36.2 V, beta_Voc=-0.378%/C, Isc=8.88 A, STC=240.0 W, Area=1.633 m2.

Result: 14 panels max on 600 V (573.9 V); 34 panels for 8 kW (598 sq ft).

What Are the Published CEC Specifications for Zebra Energy ZBR-240PA?

Complete CEC test sheet for Zebra Energy ZBR-240PA including Isc (8.88 A), Voc (36.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Zebra Energy ZBR-240PA.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 240.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 216.8 W (90.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.88 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.7 V / 8.08 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.378 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.69% (1.633 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Zebra Energy ZBR-240PA Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Zebra Energy ZBR-240PA.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.0 kW 439 sq ft $1,502 $2,539
8 kW Class 34 8.16 kW 598 sq ft $2,042 $3,454
10 kW Class 42 10.08 kW 738 sq ft $2,523 $4,266

How Many Zebra Energy ZBR-240PA Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Zebra Energy ZBR-240PA (36.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=36.2V and beta_Voc=-0.378%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.36 V 14 panels 593.0 V 23 panels
-10 C (14 F) 40.99 V 14 panels 573.9 V 24 panels
0 C (32 F) 39.62 V 15 panels 594.3 V 25 panels
25 C (77 F STC) 36.2 V 16 panels 579.2 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Zebra Energy ZBR-240PA?

Four comparable CEC modules such as Chinaland Solar Energy HSE240-60P (240.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Chinaland Solar Energy HSE240-60P
Chinaland Solar Energy
240.0 W Tie (0 W) 35.7 V 14.78% 88.4%
Chinaland Solar Energy HSE240-60P-B
Chinaland Solar Energy
240.0 W Tie (0 W) 35.7 V 14.04% 88.8%
Centrosolar America DM60 240
Centrosolar America
240.0 W Tie (0 W) 36.8 V 14.64% 90.6%
Heliene 60M240
Heliene
240.0 W Tie (0 W) 36.8 V 14.43% 90.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Zebra Energy ZBR-240PA?

Evaluate Zebra Energy ZBR-240PA (240.0 W STC, 36.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Zebra Energy ZBR-240PA reaches 42.36 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 34 panels for an 8 kW build require 598 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (598 sq ft).
  • 2026 tax credit baseline: cash residential installs of Zebra Energy ZBR-240PA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Zebra Energy ZBR-240PA 8 kW Residential Fit

Needs 34 modules (598 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Chinaland Solar Energy HSE240-60P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 216.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Zebra Energy ZBR-240PA by Zebra Energy grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Zebra Energy ZBR-240PA PTC wattage (216.8 W) lower than STC (240.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 216.8 W PTC (90.3% retention) across Zebra Energy ZBR-240PA's 1.633 m2 aperture.

Who should skip Zebra Energy ZBR-240PA on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 34 Zebra Energy ZBR-240PA panels (598 sq ft) leave unusable roof gaps vs. Chinaland Solar Energy HSE240-60P.

What is the 1,000 V commercial string limit for Zebra Energy ZBR-240PA?

On 1,000 V commercial inverters at -10 C (40.99 V cold Voc), Zebra Energy ZBR-240PA fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Zebra Energy ZBR-240PA.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.