Zebra Energy ZBR-230P — CEC Solar Module Specifications

Manufacturer: Zebra Energy Registry: CEC Verified Engineering Specification

Zebra Energy ZBR-230P is a 230.0 W STC (203.1 W PTC) Multi-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 14.08% efficiency, 37.48 V Voc at 25 C, and 42.07 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
230.0 W
PTC Wattage
203.1 W
Voc @ 25C
37.48 V
Efficiency
14.08%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Zebra Energy ZBR-230P Compare Against Peer CEC Listings?

Engineering position of Zebra Energy ZBR-230P (230.0 W STC) vs. APOS Energy AP230 across 1,407 CEC Multi-c-Si solar modules.

Ranking #20,522 across 21,677 CEC solar panels (below all-CEC median; higher than 4.7% of peers), Zebra Energy ZBR-230P operates as a compact residential or specialty off-grid module sitting 48.8 W below the 278.8 W Multi-c-Si median. Lower 37.48 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 88.3% PTC-to-STC thermal output (203.1 W real-world rating), 35 panels occupy 615 sq ft and offset roughly $2,015/yr at average US rates (or $3,407/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Zebra Energy ZBR-230P Fall Across Listed CEC Models?

Plots Zebra Energy ZBR-230P at 230.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Zebra Energy ZBR-230P (230.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZebra Energy ZBR-2: 230.0 W

What Dataset Percentiles Define Zebra Energy ZBR-230P?

Benchmarks Zebra Energy ZBR-230P on STC wattage, thermal PTC/STC retention, and 14.08 aperture conversion efficiency against CEC peers.

Zebra Energy ZBR-230P Engineering BenchmarksPercentile comparison of Zebra Energy ZBR-230P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage230.0 WPTC/STC Retention88.3%Module Efficiency14.08%

What Do the Dataset Ranks Show for Zebra Energy ZBR-230P?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Zebra Energy ZBR-230P by Zebra Energy.

Rank #20,522 / 21,677

230.0 W STC · Higher Than 4.7%

230.0 W STC (-155.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,835

14.08% Aperture Efficiency

Power density 140.8 W/m2 (5.83 percentage points below 19.91% CEC median). PTC/STC ratio: 88.3% (rank #21,245).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.07 V at -10 C (589.0 V string) and 43.38 V at -20 C (13 max).

8 kW Reference Array

35 Panels = 8,050 W STC

Occupies 57.2 m2 (615 sq ft) producing 7,108 W PTC; NEC 690.8 OCPD floor is 13.7 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.48 * (1 + (-0.35/100) * (-10 - 25)) = 42.07 V | OCPD = 1.56 * 8.78 = 13.7 A

Inputs from CEC Modules.csv for Zebra Energy ZBR-230P: Voc=37.48 V, beta_Voc=-0.35%/C, Isc=8.78 A, STC=230.0 W, Area=1.633 m2.

Result: 14 panels max on 600 V (589.0 V); 35 panels for 8 kW (615 sq ft).

What Are the Published CEC Specifications for Zebra Energy ZBR-230P?

Laboratory test ratings recorded for Zebra Energy ZBR-230P (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Zebra Energy ZBR-230P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 230.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 203.1 W (88.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.48 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.78 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.73 V / 7.81 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.35 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.08% (1.633 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Zebra Energy ZBR-230P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (615 sq ft at 8 kW), and estimated Year-1 electric bill offset for Zebra Energy ZBR-230P.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 27 6.21 kW 475 sq ft $1,554 $2,628
8 kW Class 35 8.05 kW 615 sq ft $2,015 $3,407
10 kW Class 44 10.12 kW 773 sq ft $2,533 $4,283

How Many Zebra Energy ZBR-230P Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Zebra Energy ZBR-230P (beta_Voc -0.35%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.48V and beta_Voc=-0.35%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.38 V 13 panels 563.9 V 23 panels
-10 C (14 F) 42.07 V 14 panels 589.0 V 23 panels
0 C (32 F) 40.76 V 14 panels 570.6 V 24 panels
25 C (77 F STC) 37.48 V 16 panels 599.7 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Zebra Energy ZBR-230P?

Closest cross-brand CEC competitors to Zebra Energy ZBR-230P matched near 230.0 W STC and 37.48 V Voc, led by APOS Energy AP230.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
APOS Energy AP230
APOS Energy
230.0 W Tie (0 W) 37.32 V 13.86% 89.0%
Guangdong Golden Glass Technologies GG230M2-30/1640x992
Guangdong Golden Glass Technologies
230.0 W Tie (0 W) 37.0 V 14.14% 90.3%
Anji Dasol Solar Energy Science & Technology DS-A4-230
Anji Dasol Solar Energy Science & Technology
230.0 W Tie (0 W) 36.9 V 13.97% 87.3%
Gintung Energy ASEC-230G6M
Gintung Energy
230.0 W Tie (0 W) 36.87 V 14.28% 89.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Zebra Energy ZBR-230P?

Evaluate Zebra Energy ZBR-230P (230.0 W STC, 37.48 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Zebra Energy ZBR-230P reaches 43.38 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 615 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (615 sq ft).
  • 2026 tax credit baseline: cash residential installs of Zebra Energy ZBR-230P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Zebra Energy ZBR-230P 8 kW Residential Fit

Needs 35 modules (615 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare APOS Energy AP230.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 203.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Zebra Energy ZBR-230P by Zebra Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Zebra Energy ZBR-230P panels fit on a 600 V winter solar string?

At -10 C (14 F), Zebra Energy ZBR-230P cold Voc rises from 37.48 V to 42.07 V (beta_Voc -0.35%/C), capping a 600 V string at 14 panels (589.0 V).

How much roof area does an 8 kW array of Zebra Energy ZBR-230P need?

An 8 kW DC system uses 35 Zebra Energy ZBR-230P modules (8,050 W STC / 7,108 W PTC), covering roughly 615 sq ft and saving ~$2,015/yr at 18.54 c/kWh.

How does Zebra Energy ZBR-230P compare against APOS Energy AP230?

Zebra Energy ZBR-230P outputs 230.0 W STC (37.48 V Voc, rank #20,522 of 21,677), while APOS Energy AP230 delivers 230.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.