Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED WSMDIB-455 is a 455.0 W STC (424.5 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.16% efficiency, 50.3 V Voc at 25 C, and 54.61 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
424.5 W
Voc @ 25C
50.3 V
Efficiency
21.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED WSMDIB-455 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED WSMDIB-455: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from WAAREE ENERGIES LIMITED and peers, WAAREE ENERGIES LIMITED WSMDIB-455 stands 45.0 W above the 410.0 W Mono-c-Si median and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Sizing 6 kW (14 panels) to 10 kW (22 panels) yields $1,594-$2,505/yr in baseline US bill offset. Higher 50.3 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does WAAREE ENERGIES LIMITED WSMDIB-455 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED WSMDIB-455 (455.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED WSMDIB-455 (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 455.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED WSMDIB-455?

Dataset percentiles tracking WAAREE ENERGIES LIMITED WSMDIB-455 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

WAAREE ENERGIES LIMITED WSMDIB-455 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED WSMDIB-455 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention93.3%Module Efficiency21.16%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WSMDIB-455?

Benchmark highlights for WAAREE ENERGIES LIMITED WSMDIB-455 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,699

21.16% Aperture Efficiency

Power density 211.6 W/m2 (1.25 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.61 V at -10 C (546.1 V string) and 55.85 V at -20 C (10 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,641 W PTC; NEC 690.8 OCPD floor is 17.99 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.3 * (1 + (-0.245/100) * (-10 - 25)) = 54.61 V | OCPD = 1.56 * 11.53 = 17.99 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WSMDIB-455: Voc=50.3 V, beta_Voc=-0.245%/C, Isc=11.53 A, STC=455.0 W, Area=2.15 m2.

Result: 10 panels max on 600 V (546.1 V); 18 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WSMDIB-455?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED WSMDIB-455 (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WSMDIB-455.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 424.5 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.53 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.02 V / 10.84 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.245 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.16% (2.15 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many WAAREE ENERGIES LIMITED WSMDIB-455 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED WSMDIB-455 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 324 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 417 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 509 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED WSMDIB-455 mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WSMDIB-455 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED WSMDIB-450 450.0 W 419.7 W 50.1 V 41.81 V 20.93%
WAAREE ENERGIES LIMITED WSMDIB-455 455.0 W 424.5 W 50.3 V 42.02 V 21.16%

How Many WAAREE ENERGIES LIMITED WSMDIB-455 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED WSMDIB-455 (54.61 V at 14 F).

Computed from Voc=50.3V and beta_Voc=-0.245%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.85 V 10 panels 558.5 V 17 panels
-10 C (14 F) 54.61 V 10 panels 546.1 V 18 panels
0 C (32 F) 53.38 V 11 panels 587.2 V 18 panels
25 C (77 F STC) 50.3 V 11 panels 553.3 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WSMDIB-455?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED WSMDIB-455 in nameplate wattage and Voc, starting with Bluesun Solar CoLtd BSM455M-72HBD.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar CoLtd BSM455M-72HBD
Bluesun Solar CoLtd
455.0 W Tie (0 W) 50.6 V 20.97% 92.7%
Caterpillar Inc PVC455MB03H
Caterpillar Inc
455.0 W Tie (0 W) 49.8 V 21.56% 93.8%
CSI Solar Co Ltd CS3W-455MB-AG
CSI Solar Co Ltd
455.0 W Tie (0 W) 49.3 V 21.06% 92.9%
Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF
Boviet Solar Technology Co Ltd
455.0 W Tie (0 W) 49.25 V 20.4% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WSMDIB-455?

Evaluate WAAREE ENERGIES LIMITED WSMDIB-455 (455.0 W STC, 50.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WSMDIB-455 reaches 55.85 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 417 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (417 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WSMDIB-455 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED WSMDIB-455 8 kW Residential Fit

Needs 18 modules (417 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM455M-72HBD.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 424.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WSMDIB-455 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WSMDIB-455?

Multiplying WAAREE ENERGIES LIMITED WSMDIB-455's 11.53 A short-circuit current by 1.56 equals 17.99 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can WAAREE ENERGIES LIMITED WSMDIB-455 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.61 V cold Voc at 14 F and handles 11.53 A Isc; string inverters cap WAAREE ENERGIES LIMITED WSMDIB-455 at 10 panels on 600 V.

Is WAAREE ENERGIES LIMITED WSMDIB-455 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WSMDIB-455 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.