WAAREE ENERGIES LIMITED WSMDB-405 is a 405.0 W STC (381.0 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.98% efficiency, 37.18 V Voc at 25 C, and 40.49 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 381.0 W
- Voc @ 25C
- 37.18 V
- Efficiency
- 20.98%
How Does WAAREE ENERGIES LIMITED WSMDB-405 Compare Against Peer CEC Listings?
How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED WSMDB-405 handles rooftop heat (381.0 W PTC), 8 kW sizing, and cold winter string voltage.
WAAREE ENERGIES LIMITED builds the WAAREE ENERGIES LIMITED WSMDB-405 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 209.8 W/m2 (1.07 percentage points above 19.91% CEC median). Compared against ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS (405.0 W), this model holds strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677). Lower 37.18 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.42 A overcurrent floor served by a 25 A breaker.
Where Does WAAREE ENERGIES LIMITED WSMDB-405 Fall Across Listed CEC Models?
Where WAAREE ENERGIES LIMITED WSMDB-405 (405.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define WAAREE ENERGIES LIMITED WSMDB-405?
Percentile placement of WAAREE ENERGIES LIMITED WSMDB-405 across power density (209.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WSMDB-405?
Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED WSMDB-405 specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.98% Aperture Efficiency
Power density 209.8 W/m2 (1.07 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.49 V at -10 C (566.9 V string) and 41.43 V at -20 C (14 max).
20 Panels = 8,100 W STC
Occupies 38.6 m2 (415 sq ft) producing 7,620 W PTC; NEC 690.8 OCPD floor is 21.42 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.18 * (1 + (-0.254/100) * (-10 - 25)) = 40.49 V | OCPD = 1.56 * 13.73 = 21.42 A
Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WSMDB-405: Voc=37.18 V, beta_Voc=-0.254%/C, Isc=13.73 A, STC=405.0 W, Area=1.93 m2.
Result: 14 panels max on 600 V (566.9 V); 20 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WSMDB-405?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED WSMDB-405.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 381.0 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.31 V / 12.95 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.254 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.98% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many WAAREE ENERGIES LIMITED WSMDB-405 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED WSMDB-405 (405.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 312 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 415 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 519 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?
All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED WSMDB-405 architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| WAAREE ENERGIES LIMITED WSMDB-400 | 400.0 W | 376.2 W | 37.06 V | 31.19 V | 20.73% |
| WAAREE ENERGIES LIMITED WSMDB-405 | 405.0 W | 381.0 W | 37.18 V | 31.31 V | 20.98% |
How Many WAAREE ENERGIES LIMITED WSMDB-405 Modules Fit in a Cold-Weather String?
Maximum series module counts for WAAREE ENERGIES LIMITED WSMDB-405 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.43 V | 14 panels | 580.0 V | 24 panels |
| -10 C (14 F) | 40.49 V | 14 panels | 566.9 V | 24 panels |
| 0 C (32 F) | 39.54 V | 15 panels | 593.1 V | 25 panels |
| 25 C (77 F STC) | 37.18 V | 16 panels | 594.9 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WSMDB-405?
Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED WSMDB-405 (405.0 W), including ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
405.0 W | Tie (0 W) | 37.2 V | 20.98% | 93.4% |
| AXITEC AC-405MBT/108V AXITEC |
405.0 W | Tie (0 W) | 37.2 V | 20.98% | 93.4% |
| Aptos Solar Technology LLC DNA-108-BF10-405W Aptos Solar Technology LLC |
405.0 W | Tie (0 W) | 37.23 V | 20.98% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154T 405W Dehui Solar Power (Vietnam) CoLtd |
405.0 W | Tie (0 W) | 37.23 V | 20.98% | 93.3% |
What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WSMDB-405?
Evaluate WAAREE ENERGIES LIMITED WSMDB-405 (405.0 W STC, 37.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WSMDB-405 reaches 41.43 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WSMDB-405 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
WAAREE ENERGIES LIMITED WSMDB-405 8 kW Residential Fit
Needs 20 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 381.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for WAAREE ENERGIES LIMITED WSMDB-405 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WSMDB-405?
Multiplying WAAREE ENERGIES LIMITED WSMDB-405's 13.73 A short-circuit current by 1.56 equals 21.42 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can WAAREE ENERGIES LIMITED WSMDB-405 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.49 V cold Voc at 14 F and handles 13.73 A Isc; string inverters cap WAAREE ENERGIES LIMITED WSMDB-405 at 14 panels on 600 V.
Is WAAREE ENERGIES LIMITED WSMDB-405 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WSMDB-405 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)