AXITEC AC-405MBT/108V is a 405.0 W STC (378.1 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.98% efficiency, 37.2 V Voc at 25 C, and 40.43 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 378.1 W
- Voc @ 25C
- 37.2 V
- Efficiency
- 20.98%
How Does AXITEC AC-405MBT/108V Compare Against Peer CEC Listings?
Engineering position of AXITEC AC-405MBT/108V (405.0 W STC) vs. ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS across 5,889 CEC Mono-c-Si solar modules.
Built with 54 Mono-c-Si cells, AXITEC AC-405MBT/108V pairs strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677) with 37.2 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,562 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS offers a 405.0 W alternative.
Where Does AXITEC AC-405MBT/108V Fall Across Listed CEC Models?
Plots AXITEC AC-405MBT/108V at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-405MBT/108V?
Benchmarks AXITEC AC-405MBT/108V on STC wattage, thermal PTC/STC retention, and 20.98 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for AXITEC AC-405MBT/108V?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-405MBT/108V by AXITEC.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.98% Aperture Efficiency
Power density 209.8 W/m2 (1.07 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.43 V at -10 C (566.0 V string) and 41.35 V at -20 C (14 max).
20 Panels = 8,100 W STC
Occupies 38.6 m2 (415 sq ft) producing 7,562 W PTC; NEC 690.8 OCPD floor is 21.64 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.2 * (1 + (-0.248/100) * (-10 - 25)) = 40.43 V | OCPD = 1.56 * 13.87 = 21.64 A
Inputs from CEC Modules.csv for AXITEC AC-405MBT/108V: Voc=37.2 V, beta_Voc=-0.248%/C, Isc=13.87 A, STC=405.0 W, Area=1.93 m2.
Result: 14 panels max on 600 V (566.0 V); 20 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for AXITEC AC-405MBT/108V?
Laboratory test ratings recorded for AXITEC AC-405MBT/108V (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 378.1 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.87 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.2 V / 12.98 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.248 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.98% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many AXITEC AC-405MBT/108V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (415 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-405MBT/108V.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 312 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 415 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 519 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Sibling wattage bins and frame colors grouped with AXITEC AC-405MBT/108V under AXITEC to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-400MBT/108V | 400.0 W | 373.3 W | 37.1 V | 31.0 V | 20.73% |
| AXITEC AC-405MBT/108V | 405.0 W | 378.1 W | 37.2 V | 31.2 V | 20.98% |
| AXITEC AC-410MBT/108V | 410.0 W | 382.9 W | 37.3 V | 31.5 V | 21.24% |
How Many AXITEC AC-405MBT/108V Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for AXITEC AC-405MBT/108V (beta_Voc -0.248%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.35 V | 14 panels | 578.9 V | 24 panels |
| -10 C (14 F) | 40.43 V | 14 panels | 566.0 V | 24 panels |
| 0 C (32 F) | 39.51 V | 15 panels | 592.6 V | 25 panels |
| 25 C (77 F STC) | 37.2 V | 16 panels | 595.2 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-405MBT/108V?
Closest cross-brand CEC competitors to AXITEC AC-405MBT/108V matched near 405.0 W STC and 37.2 V Voc, led by ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
405.0 W | Tie (0 W) | 37.2 V | 20.98% | 93.4% |
| Aptos Solar Technology LLC DNA-108-BF10-405W Aptos Solar Technology LLC |
405.0 W | Tie (0 W) | 37.23 V | 20.98% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154T 405W Dehui Solar Power (Vietnam) CoLtd |
405.0 W | Tie (0 W) | 37.23 V | 20.98% | 93.3% |
| Belinus Solar BV BE-M7-GG-108-405 Belinus Solar BV |
405.0 W | Tie (0 W) | 37.36 V | 20.77% | 93.8% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-405MBT/108V?
Evaluate AXITEC AC-405MBT/108V (405.0 W STC, 37.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-405MBT/108V reaches 41.35 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-405MBT/108V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-405MBT/108V 8 kW Residential Fit
Needs 20 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 378.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-405MBT/108V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for AXITEC AC-405MBT/108V?
Multiplying AXITEC AC-405MBT/108V's 13.87 A short-circuit current by 1.56 equals 21.64 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can AXITEC AC-405MBT/108V pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.43 V cold Voc at 14 F and handles 13.87 A Isc; string inverters cap AXITEC AC-405MBT/108V at 14 panels on 600 V.
Is AXITEC AC-405MBT/108V eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-405MBT/108V rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)