Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED WSMD-405 is a 405.0 W STC (377.4 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.25% efficiency, 49.71 V Voc at 25 C, and 53.82 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
377.4 W
Voc @ 25C
49.71 V
Efficiency
20.25%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED WSMD-405 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED WSMD-405: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from WAAREE ENERGIES LIMITED and peers, WAAREE ENERGIES LIMITED WSMD-405 stands 5.0 W below the 410.0 W Mono-c-Si median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,522-$2,533/yr in baseline US bill offset. Higher 49.71 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does WAAREE ENERGIES LIMITED WSMD-405 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED WSMD-405 (405.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED WSMD-405 (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 405.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED WSMD-405?

Dataset percentiles tracking WAAREE ENERGIES LIMITED WSMD-405 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

WAAREE ENERGIES LIMITED WSMD-405 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED WSMD-405 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention93.2%Module Efficiency20.25%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WSMD-405?

Benchmark highlights for WAAREE ENERGIES LIMITED WSMD-405 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,573

20.25% Aperture Efficiency

Power density 202.5 W/m2 (0.34 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.82 V at -10 C (592.0 V string) and 54.99 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 40.0 m2 (431 sq ft) producing 7,548 W PTC; NEC 690.8 OCPD floor is 16.36 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.71 * (1 + (-0.236/100) * (-10 - 25)) = 53.82 V | OCPD = 1.56 * 10.49 = 16.36 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WSMD-405: Voc=49.71 V, beta_Voc=-0.236%/C, Isc=10.49 A, STC=405.0 W, Area=2.0 m2.

Result: 11 panels max on 600 V (592.0 V); 20 panels for 8 kW (431 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WSMD-405?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED WSMD-405 (Mono-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WSMD-405.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 377.4 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.71 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.49 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.33 V / 10.05 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.236 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.25% (2.0 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many WAAREE ENERGIES LIMITED WSMD-405 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED WSMD-405 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 323 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 431 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 538 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED WSMD-405 mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WSMD-405 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED WSMD-400 400.0 W 372.7 W 49.39 V 40.07 V 20.0%
WAAREE ENERGIES LIMITED WSMD-405 405.0 W 377.4 W 49.71 V 40.33 V 20.25%

How Many WAAREE ENERGIES LIMITED WSMD-405 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED WSMD-405 (53.82 V at 14 F).

Computed from Voc=49.71V and beta_Voc=-0.236%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.99 V 10 panels 549.9 V 18 panels
-10 C (14 F) 53.82 V 11 panels 592.0 V 18 panels
0 C (32 F) 52.64 V 11 panels 579.0 V 18 panels
25 C (77 F STC) 49.71 V 12 panels 596.5 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WSMD-405?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED WSMD-405 in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612M-405L-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-405L-H
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 20.35% 93.3%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 19.95% 93.6%
CSI Solar Co Ltd CS3U-405MS
CSI Solar Co Ltd
405.0 W Tie (0 W) 49.3 V 21.09% 93.0%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
405.0 W Tie (0 W) 49.2 V 21.2% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WSMD-405?

Evaluate WAAREE ENERGIES LIMITED WSMD-405 (405.0 W STC, 49.71 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WSMD-405 reaches 54.99 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 431 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (431 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WSMD-405 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED WSMD-405 8 kW Residential Fit

Needs 20 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-405L-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 377.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WSMD-405 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WSMD-405?

Multiplying WAAREE ENERGIES LIMITED WSMD-405's 10.49 A short-circuit current by 1.56 equals 16.36 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can WAAREE ENERGIES LIMITED WSMD-405 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.82 V cold Voc at 14 F and handles 10.49 A Isc; string inverters cap WAAREE ENERGIES LIMITED WSMD-405 at 11 panels on 600 V.

Is WAAREE ENERGIES LIMITED WSMD-405 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WSMD-405 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.