Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED WSMB-340 is a 340.0 W STC (309.6 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 17.71% efficiency, 47.15 V Voc at 25 C, and 52.61 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
340.0 W
PTC Wattage
309.6 W
Voc @ 25C
47.15 V
Efficiency
17.71%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED WSMB-340 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED WSMB-340: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 340.0 W STC and 309.6 W PTC, WAAREE ENERGIES LIMITED WSMB-340 sits -45.0 W vs all-CEC median (below all-CEC median; higher than 36.1% of peers) among 21,677 listed modules. Power density reaches 177.1 W/m2 (2.20 percentage points below 19.91% CEC median). Mid-range 47.15 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Advance Power API-M340 rates 340.0 W.

Where Does WAAREE ENERGIES LIMITED WSMB-340 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED WSMB-340 (340.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED WSMB-340 (340.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 340.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED WSMB-340?

Dataset percentiles tracking WAAREE ENERGIES LIMITED WSMB-340 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

WAAREE ENERGIES LIMITED WSMB-340 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED WSMB-340 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage340.0 WPTC/STC Retention91.1%Module Efficiency17.71%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WSMB-340?

Benchmark highlights for WAAREE ENERGIES LIMITED WSMB-340 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #13,575 / 21,677

340.0 W STC · Higher Than 36.1%

340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,498

17.71% Aperture Efficiency

Power density 177.1 W/m2 (2.20 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.61 V at -10 C (578.7 V string) and 54.17 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,160 W STC

Occupies 46.1 m2 (496 sq ft) producing 7,430 W PTC; NEC 690.8 OCPD floor is 14.82 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.15 * (1 + (-0.331/100) * (-10 - 25)) = 52.61 V | OCPD = 1.56 * 9.5 = 14.82 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WSMB-340: Voc=47.15 V, beta_Voc=-0.331%/C, Isc=9.5 A, STC=340.0 W, Area=1.92 m2.

Result: 11 panels max on 600 V (578.7 V); 24 panels for 8 kW (496 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WSMB-340?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED WSMB-340 (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WSMB-340.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 340.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 309.6 W (91.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.15 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.1 V / 8.93 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.331 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.71% (1.92 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many WAAREE ENERGIES LIMITED WSMB-340 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED WSMB-340 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.12 kW 372 sq ft $1,532 $2,590
8 kW Class 24 8.16 kW 496 sq ft $2,042 $3,454
10 kW Class 30 10.2 kW 620 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED WSMB-340 mechanical and cell layout. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WSMB-340 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED WSMB-330 330.0 W 300.2 W 46.9 V 37.7 V 17.19%
WAAREE ENERGIES LIMITED WSMB-335 335.0 W 304.9 W 47.05 V 37.9 V 17.45%
WAAREE ENERGIES LIMITED WSMB-340 340.0 W 309.6 W 47.15 V 38.1 V 17.71%
WAAREE ENERGIES LIMITED WSMB-345 345.0 W 314.3 W 47.25 V 38.3 V 17.97%

How Many WAAREE ENERGIES LIMITED WSMB-340 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED WSMB-340 (52.61 V at 14 F).

Computed from Voc=47.15V and beta_Voc=-0.331%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.17 V 11 panels 595.9 V 18 panels
-10 C (14 F) 52.61 V 11 panels 578.7 V 19 panels
0 C (32 F) 51.05 V 11 panels 561.5 V 19 panels
25 C (77 F STC) 47.15 V 12 panels 565.8 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WSMB-340?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED WSMB-340 in nameplate wattage and Voc, starting with Advance Power API-M340.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-M340
Advance Power
340.0 W Tie (0 W) 47.18 V 17.53% 91.7%
DEHUI SOLAR POWER INC DH-72M-340W
DEHUI SOLAR POWER INC
340.0 W Tie (0 W) 47.3 V 17.68% 91.3%
Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72
Anhui Rinengzhongtian Semiconductor Development Co Ltd
340.0 W Tie (0 W) 46.97 V 17.52% 91.0%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
340.0 W Tie (0 W) 46.91 V 17.68% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WSMB-340?

Evaluate WAAREE ENERGIES LIMITED WSMB-340 (340.0 W STC, 47.15 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WSMB-340 reaches 54.17 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 496 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (496 sq ft).
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WSMB-340 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED WSMB-340 8 kW Residential Fit

Needs 24 modules (496 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-M340.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 309.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WSMB-340 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

How many WAAREE ENERGIES LIMITED WSMB-340 panels fit on a 600 V winter solar string?

At -10 C (14 F), WAAREE ENERGIES LIMITED WSMB-340 cold Voc rises from 47.15 V to 52.61 V (beta_Voc -0.331%/C), capping a 600 V string at 11 panels (578.7 V).

How much roof area does an 8 kW array of WAAREE ENERGIES LIMITED WSMB-340 need?

An 8 kW DC system uses 24 WAAREE ENERGIES LIMITED WSMB-340 modules (8,160 W STC / 7,430 W PTC), covering roughly 496 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does WAAREE ENERGIES LIMITED WSMB-340 compare against Advance Power API-M340?

WAAREE ENERGIES LIMITED WSMB-340 outputs 340.0 W STC (47.15 V Voc, rank #13,575 of 21,677), while Advance Power API-M340 delivers 340.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.