WAAREE ENERGIES LIMITED WSMB-270 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED WSMB-270 is a 270.0 W STC (247.2 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.67% efficiency, 39.1 V Voc at 25 C, and 43.37 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
247.2 W
Voc @ 25C
39.1 V
Efficiency
16.67%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED WSMB-270 Compare Against Peer CEC Listings?

How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED WSMB-270 handles rooftop heat (247.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, WAAREE ENERGIES LIMITED WSMB-270 exhibits 8.95 A short-circuit current, requiring a 13.96 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,572 of 21,677 (140.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 48.6 m2 for an 8 kW system (38 panels for 10 kW). Lower 39.1 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does WAAREE ENERGIES LIMITED WSMB-270 Fall Across Listed CEC Models?

Where WAAREE ENERGIES LIMITED WSMB-270 (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED WSMB-270 (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 270.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED WSMB-270?

Percentile placement of WAAREE ENERGIES LIMITED WSMB-270 across power density (166.7 W/m2), thermal retention, and nameplate STC wattage.

WAAREE ENERGIES LIMITED WSMB-270 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED WSMB-270 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention91.6%Module Efficiency16.67%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WSMB-270?

Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED WSMB-270 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #17,034

16.67% Aperture Efficiency

Power density 166.7 W/m2 (3.24 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.37 V at -10 C (563.8 V string) and 44.59 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 48.6 m2 (523 sq ft) producing 7,416 W PTC; NEC 690.8 OCPD floor is 13.96 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.1 * (1 + (-0.312/100) * (-10 - 25)) = 43.37 V | OCPD = 1.56 * 8.95 = 13.96 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WSMB-270: Voc=39.1 V, beta_Voc=-0.312%/C, Isc=8.95 A, STC=270.0 W, Area=1.62 m2.

Result: 13 panels max on 600 V (563.8 V); 30 panels for 8 kW (523 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WSMB-270?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED WSMB-270.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WSMB-270.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 247.2 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.8 V / 8.5 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.312 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.67% (1.62 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many WAAREE ENERGIES LIMITED WSMB-270 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED WSMB-270 (270.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 401 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 523 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 663 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED WSMB-270 architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WSMB-270 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED WSMB-265 265.0 W 242.5 W 39.0 V 31.55 V 16.36%
WAAREE ENERGIES LIMITED WSMB-270 270.0 W 247.2 W 39.1 V 31.8 V 16.67%

How Many WAAREE ENERGIES LIMITED WSMB-270 Modules Fit in a Cold-Weather String?

Maximum series module counts for WAAREE ENERGIES LIMITED WSMB-270 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.1V and beta_Voc=-0.312%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.59 V 13 panels 579.7 V 22 panels
-10 C (14 F) 43.37 V 13 panels 563.8 V 23 panels
0 C (32 F) 42.15 V 14 panels 590.1 V 23 panels
25 C (77 F STC) 39.1 V 15 panels 586.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WSMB-270?

Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED WSMB-270 (270.0 W), including Centrosolar America EM60 270SW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America EM60 270SW
Centrosolar America
270.0 W Tie (0 W) 38.68 V 16.76% 91.3%
Ablytek 6MN6A270
Ablytek
270.0 W Tie (0 W) 38.63 V 16.6% 89.7%
DEHUI SOLAR POWER INC DH-60M-270W
DEHUI SOLAR POWER INC
270.0 W Tie (0 W) 38.57 V 16.77% 91.1%
Flextronics FXS-270BB-SAC1B
Flextronics
270.0 W Tie (0 W) 38.5 V 16.45% 91.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WSMB-270?

Evaluate WAAREE ENERGIES LIMITED WSMB-270 (270.0 W STC, 39.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WSMB-270 reaches 44.59 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 523 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (523 sq ft).
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WSMB-270 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED WSMB-270 8 kW Residential Fit

Needs 30 modules (523 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America EM60 270SW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 247.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WSMB-270 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

Why is WAAREE ENERGIES LIMITED WSMB-270 PTC wattage (247.2 W) lower than STC (270.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 247.2 W PTC (91.6% retention) across WAAREE ENERGIES LIMITED WSMB-270's 1.62 m2 aperture.

Who should skip WAAREE ENERGIES LIMITED WSMB-270 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 WAAREE ENERGIES LIMITED WSMB-270 panels (523 sq ft) leave unusable roof gaps vs. Centrosolar America EM60 270SW.

What is the 1,000 V commercial string limit for WAAREE ENERGIES LIMITED WSMB-270?

On 1,000 V commercial inverters at -10 C (43.37 V cold Voc), WAAREE ENERGIES LIMITED WSMB-270 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WAAREE ENERGIES LIMITED WSMB-270.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.