Skip to main content
WireAndSun
Calculators
CEC PV Module

Centrosolar America EM60 270SW — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America EM60 270SW is a 270.0 W STC (246.5 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.76% efficiency, 38.68 V Voc at 25 C, and 42.7 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
246.5 W
Voc @ 25C
38.68 V
Efficiency
16.76%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America EM60 270SW Compare Against Peer CEC Listings?

Engineering position of Centrosolar America EM60 270SW (270.0 W STC) vs. Ablytek 6MN6A270 across 5,889 CEC Mono-c-Si solar modules.

Ranking #18,572 across 21,677 CEC solar panels (below all-CEC median; higher than 12.9% of peers), Centrosolar America EM60 270SW operates as a compact residential or specialty off-grid module sitting 140.0 W below the 410.0 W Mono-c-Si median. Lower 38.68 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 91.3% PTC-to-STC thermal output (246.5 W real-world rating), 30 panels occupy 520 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Centrosolar America EM60 270SW Fall Across Listed CEC Models?

Plots Centrosolar America EM60 270SW at 270.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America EM60 270SW (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 270.0 W

What Dataset Percentiles Define Centrosolar America EM60 270SW?

Benchmarks Centrosolar America EM60 270SW on STC wattage, thermal PTC/STC retention, and 16.76 aperture conversion efficiency against CEC peers.

Centrosolar America EM60 270SW Engineering BenchmarksPercentile comparison of Centrosolar America EM60 270SW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention91.3%Module Efficiency16.76%

What Do the Dataset Ranks Show for Centrosolar America EM60 270SW?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Centrosolar America EM60 270SW by Centrosolar America.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,871

16.76% Aperture Efficiency

Power density 167.6 W/m2 (3.15 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.7 V at -10 C (597.8 V string) and 43.85 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 48.3 m2 (520 sq ft) producing 7,395 W PTC; NEC 690.8 OCPD floor is 14.23 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.68 * (1 + (-0.297/100) * (-10 - 25)) = 42.7 V | OCPD = 1.56 * 9.12 = 14.23 A

Inputs from CEC Modules.csv for Centrosolar America EM60 270SW: Voc=38.68 V, beta_Voc=-0.297%/C, Isc=9.12 A, STC=270.0 W, Area=1.611 m2.

Result: 14 panels max on 600 V (597.8 V); 30 panels for 8 kW (520 sq ft).

What Are the Published CEC Specifications for Centrosolar America EM60 270SW?

Laboratory test ratings recorded for Centrosolar America EM60 270SW (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America EM60 270SW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 246.5 W (91.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.68 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.12 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.83 V / 8.76 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.297 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.76% (1.611 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Centrosolar America EM60 270SW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (520 sq ft at 8 kW), and estimated Year-1 electric bill offset for Centrosolar America EM60 270SW.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 399 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 520 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 659 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Sibling wattage bins and frame colors grouped with Centrosolar America EM60 270SW under Centrosolar America to prevent duplicate spec pages.

Sibling CEC listings grouped into the Centrosolar America EM60 270SW wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America EM60 265SW 265.0 W 241.9 W 38.29 V 30.64 V 16.45%
Centrosolar America EM60 270SW 270.0 W 246.5 W 38.68 V 30.83 V 16.76%

How Many Centrosolar America EM60 270SW Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Centrosolar America EM60 270SW (beta_Voc -0.297%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=38.68V and beta_Voc=-0.297%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.85 V 13 panels 570.1 V 22 panels
-10 C (14 F) 42.7 V 14 panels 597.8 V 23 panels
0 C (32 F) 41.55 V 14 panels 581.7 V 24 panels
25 C (77 F STC) 38.68 V 15 panels 580.2 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America EM60 270SW?

Closest cross-brand CEC competitors to Centrosolar America EM60 270SW matched near 270.0 W STC and 38.68 V Voc, led by Ablytek 6MN6A270.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Ablytek 6MN6A270
Ablytek
270.0 W Tie (0 W) 38.63 V 16.6% 89.7%
DEHUI SOLAR POWER INC DH-60M-270W
DEHUI SOLAR POWER INC
270.0 W Tie (0 W) 38.57 V 16.77% 91.1%
Flextronics FXS-270BB-SAC1B
Flextronics
270.0 W Tie (0 W) 38.5 V 16.45% 91.3%
Bluesun Solar Energy Tech CoLtd BSM270M-60
Bluesun Solar Energy Tech CoLtd
270.0 W Tie (0 W) 38.46 V 16.6% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America EM60 270SW?

Evaluate Centrosolar America EM60 270SW (270.0 W STC, 38.68 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America EM60 270SW reaches 43.85 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 520 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (520 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America EM60 270SW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America EM60 270SW 8 kW Residential Fit

Needs 30 modules (520 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Ablytek 6MN6A270.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 246.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America EM60 270SW by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

How many Centrosolar America EM60 270SW panels fit on a 600 V winter solar string?

At -10 C (14 F), Centrosolar America EM60 270SW cold Voc rises from 38.68 V to 42.7 V (beta_Voc -0.297%/C), capping a 600 V string at 14 panels (597.8 V).

How much roof area does an 8 kW array of Centrosolar America EM60 270SW need?

An 8 kW DC system uses 30 Centrosolar America EM60 270SW modules (8,100 W STC / 7,395 W PTC), covering roughly 520 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Centrosolar America EM60 270SW compare against Ablytek 6MN6A270?

Centrosolar America EM60 270SW outputs 270.0 W STC (38.68 V Voc, rank #18,572 of 21,677), while Ablytek 6MN6A270 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.