WAAREE ENERGIES LIMITED WSM-340 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED WSM-340 is a 340.0 W STC (311.3 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 17.71% efficiency, 47.15 V Voc at 25 C, and 52.45 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
340.0 W
PTC Wattage
311.3 W
Voc @ 25C
47.15 V
Efficiency
17.71%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED WSM-340 Compare Against Peer CEC Listings?

How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED WSM-340 handles rooftop heat (311.3 W PTC), 8 kW sizing, and cold winter string voltage.

WAAREE ENERGIES LIMITED builds the WAAREE ENERGIES LIMITED WSM-340 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 177.1 W/m2 (2.20 percentage points below 19.91% CEC median). Compared against Advance Power API-M340 (340.0 W), this model holds strong 91.6% PTC-to-STC heat retention (#15,328 of 21,677). Mid-range 47.15 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.82 A overcurrent floor served by a 15 A breaker.

Where Does WAAREE ENERGIES LIMITED WSM-340 Fall Across Listed CEC Models?

Where WAAREE ENERGIES LIMITED WSM-340 (340.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED WSM-340 (340.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 340.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED WSM-340?

Percentile placement of WAAREE ENERGIES LIMITED WSM-340 across power density (177.1 W/m2), thermal retention, and nameplate STC wattage.

WAAREE ENERGIES LIMITED WSM-340 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED WSM-340 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage340.0 WPTC/STC Retention91.6%Module Efficiency17.71%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WSM-340?

Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED WSM-340 specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #13,575 / 21,677

340.0 W STC · Higher Than 36.1%

340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,498

17.71% Aperture Efficiency

Power density 177.1 W/m2 (2.20 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.45 V at -10 C (577.0 V string) and 53.96 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,160 W STC

Occupies 46.1 m2 (496 sq ft) producing 7,471 W PTC; NEC 690.8 OCPD floor is 14.82 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.15 * (1 + (-0.321/100) * (-10 - 25)) = 52.45 V | OCPD = 1.56 * 9.5 = 14.82 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WSM-340: Voc=47.15 V, beta_Voc=-0.321%/C, Isc=9.5 A, STC=340.0 W, Area=1.92 m2.

Result: 11 panels max on 600 V (577.0 V); 24 panels for 8 kW (496 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WSM-340?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED WSM-340.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WSM-340.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 340.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 311.3 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.15 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.1 V / 8.93 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.321 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.71% (1.92 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many WAAREE ENERGIES LIMITED WSM-340 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED WSM-340 (340.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.12 kW 372 sq ft $1,532 $2,590
8 kW Class 24 8.16 kW 496 sq ft $2,042 $3,454
10 kW Class 30 10.2 kW 620 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED WSM-340 architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WSM-340 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED WSM-330 330.0 W 301.8 W 46.9 V 37.7 V 17.19%
WAAREE ENERGIES LIMITED WSM-335 335.0 W 306.5 W 47.05 V 37.9 V 17.45%
WAAREE ENERGIES LIMITED WSM-340 340.0 W 311.3 W 47.15 V 38.1 V 17.71%
WAAREE ENERGIES LIMITED WSM-345 345.0 W 316.0 W 47.25 V 38.3 V 17.97%

How Many WAAREE ENERGIES LIMITED WSM-340 Modules Fit in a Cold-Weather String?

Maximum series module counts for WAAREE ENERGIES LIMITED WSM-340 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=47.15V and beta_Voc=-0.321%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.96 V 11 panels 593.6 V 18 panels
-10 C (14 F) 52.45 V 11 panels 577.0 V 19 panels
0 C (32 F) 50.93 V 11 panels 560.2 V 19 panels
25 C (77 F STC) 47.15 V 12 panels 565.8 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WSM-340?

Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED WSM-340 (340.0 W), including Advance Power API-M340.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-M340
Advance Power
340.0 W Tie (0 W) 47.18 V 17.53% 91.7%
DEHUI SOLAR POWER INC DH-72M-340W
DEHUI SOLAR POWER INC
340.0 W Tie (0 W) 47.3 V 17.68% 91.3%
Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72
Anhui Rinengzhongtian Semiconductor Development Co Ltd
340.0 W Tie (0 W) 46.97 V 17.52% 91.0%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
340.0 W Tie (0 W) 46.91 V 17.68% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WSM-340?

Evaluate WAAREE ENERGIES LIMITED WSM-340 (340.0 W STC, 47.15 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WSM-340 reaches 53.96 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 496 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (496 sq ft).
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WSM-340 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED WSM-340 8 kW Residential Fit

Needs 24 modules (496 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-M340.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 311.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WSM-340 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WSM-340?

Multiplying WAAREE ENERGIES LIMITED WSM-340's 9.5 A short-circuit current by 1.56 equals 14.82 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can WAAREE ENERGIES LIMITED WSM-340 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.45 V cold Voc at 14 F and handles 9.5 A Isc; string inverters cap WAAREE ENERGIES LIMITED WSM-340 at 11 panels on 600 V.

Is WAAREE ENERGIES LIMITED WSM-340 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WSM-340 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.