Skip to main content
WireAndSun
Calculators
CEC PV Module

WAAREE ENERGIES LIMITED BiN-01-565 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED BiN-01-565 is a 565.0 W STC (536.8 W PTC) Mono-c-Si solar module ranking #2,284 of 21,677 CEC listings (top 11.1%; higher than 88.9% of peers). It delivers 22.24% efficiency, 39.2 V Voc at 25 C, and 42.45 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
565.0 W
PTC Wattage
536.8 W
Voc @ 25C
39.2 V
Efficiency
22.24%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED BiN-01-565 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for WAAREE ENERGIES LIMITED BiN-01-565 (Mono-c-Si) residential solar systems.

Homeowners evaluating WAAREE ENERGIES LIMITED BiN-01-565 need 11 panels for 6 kW or 15 panels (410 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.237%/C) pushes open-circuit voltage to 42.45 V at 14 F and 43.38 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does WAAREE ENERGIES LIMITED BiN-01-565 Fall Across Listed CEC Models?

Comparison of WAAREE ENERGIES LIMITED BiN-01-565 (565.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED BiN-01-565 (565.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 565.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED BiN-01-565?

Relative ranking of WAAREE ENERGIES LIMITED BiN-01-565 across nameplate watts, 95.0% PTC thermal ratio, and module aperture efficiency.

WAAREE ENERGIES LIMITED BiN-01-565 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED BiN-01-565 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage565.0 WPTC/STC Retention95.0%Module Efficiency22.24%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED BiN-01-565?

Summary of WAAREE ENERGIES LIMITED BiN-01-565 output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,284 / 21,677

Top 11.1% STC Output

565.0 W STC (+180.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,578

22.24% Aperture Efficiency

Power density 222.4 W/m2 (2.33 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.45 V at -10 C (594.3 V string) and 43.38 V at -20 C (13 max).

8 kW Reference Array

15 Panels = 8,475 W STC

Occupies 38.1 m2 (410 sq ft) producing 8,052 W PTC; NEC 690.8 OCPD floor is 28.45 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.2 * (1 + (-0.237/100) * (-10 - 25)) = 42.45 V | OCPD = 1.56 * 18.24 = 28.45 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED BiN-01-565: Voc=39.2 V, beta_Voc=-0.237%/C, Isc=18.24 A, STC=565.0 W, Area=2.54 m2.

Result: 14 panels max on 600 V (594.3 V); 15 panels for 8 kW (410 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED BiN-01-565?

Complete CEC test sheet for WAAREE ENERGIES LIMITED BiN-01-565 including Isc (18.24 A), Voc (39.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED BiN-01-565.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 565.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 536.8 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 18.24 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.81 V / 17.22 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.237 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.24% (2.54 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many WAAREE ENERGIES LIMITED BiN-01-565 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using WAAREE ENERGIES LIMITED BiN-01-565.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.21 kW 301 sq ft $1,554 $2,628
8 kW Class 15 8.47 kW 410 sq ft $2,120 $3,585
10 kW Class 18 10.17 kW 492 sq ft $2,545 $4,304

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Related WAAREE ENERGIES LIMITED power steps and black/silver trims consolidated into this WAAREE ENERGIES LIMITED BiN-01-565 series guide.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED BiN-01-565 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED BiN-01-555 555.0 W 527.1 W 38.88 V 32.28 V 21.85%
WAAREE ENERGIES LIMITED BiN-01-560 560.0 W 532.0 W 39.04 V 32.6 V 22.05%
WAAREE ENERGIES LIMITED BiN-01-565 565.0 W 536.8 W 39.2 V 32.81 V 22.24%
WAAREE ENERGIES LIMITED BiN-01-570 570.0 W 541.7 W 39.31 V 33.02 V 22.44%

How Many WAAREE ENERGIES LIMITED BiN-01-565 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for WAAREE ENERGIES LIMITED BiN-01-565 (39.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=39.2V and beta_Voc=-0.237%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.38 V 13 panels 563.9 V 23 panels
-10 C (14 F) 42.45 V 14 panels 594.3 V 23 panels
0 C (32 F) 41.52 V 14 panels 581.3 V 24 panels
25 C (77 F STC) 39.2 V 15 panels 588.0 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED BiN-01-565?

Four comparable CEC modules such as CSI Solar Co Ltd CS7L-570MB-AG (570.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS7L-570MB-AG
CSI Solar Co Ltd
570.0 W +5.0 W 40.1 V 26.64% 93.8%
CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT550-108PMB12
CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET
550.0 W -15.0 W 37.9 V 21.48% 93.7%
CSI Solar Co Ltd CS7L-585MB-AG
CSI Solar Co Ltd
585.0 W +20.0 W 40.7 V 27.34% 93.9%
BLUESUN GROUP LIMITED BSM565M10-72HBD
BLUESUN GROUP LIMITED
565.0 W Tie (0 W) 49.84 V 21.9% 94.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED BiN-01-565?

Evaluate WAAREE ENERGIES LIMITED BiN-01-565 (565.0 W STC, 39.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED BiN-01-565 reaches 43.38 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 410 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED BiN-01-565 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED BiN-01-565 8 kW Residential Fit

Needs 15 modules (410 sq ft) with a 30 A string OCPD, offsetting ~$2,120/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS7L-570MB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 536.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED BiN-01-565 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

Why is WAAREE ENERGIES LIMITED BiN-01-565 PTC wattage (536.8 W) lower than STC (565.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 536.8 W PTC (95.0% retention) across WAAREE ENERGIES LIMITED BiN-01-565's 2.54 m2 aperture.

Who should skip WAAREE ENERGIES LIMITED BiN-01-565 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 WAAREE ENERGIES LIMITED BiN-01-565 panels (410 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS7L-570MB-AG.

What is the 1,000 V commercial string limit for WAAREE ENERGIES LIMITED BiN-01-565?

On 1,000 V commercial inverters at -10 C (42.45 V cold Voc), WAAREE ENERGIES LIMITED BiN-01-565 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WAAREE ENERGIES LIMITED BiN-01-565.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.