Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED BiH-1-380 is a 380.0 W STC (362.0 W PTC) a-Si/nc solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 18.72% efficiency, 53.28 V Voc at 25 C, and 57.55 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
362.0 W
Voc @ 25C
53.28 V
Efficiency
18.72%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED BiH-1-380 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED BiH-1-380: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 2 a-Si/nc listings from WAAREE ENERGIES LIMITED and peers, WAAREE ENERGIES LIMITED BiH-1-380 stands 32.5 W above the 347.5 W a-Si/nc median and strong 95.3% PTC-to-STC heat retention (#237 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,522-$2,568/yr in baseline US bill offset. Higher 53.28 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does WAAREE ENERGIES LIMITED BiH-1-380 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED BiH-1-380 (380.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED BiH-1-380 (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 380.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED BiH-1-380?

Dataset percentiles tracking WAAREE ENERGIES LIMITED BiH-1-380 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

WAAREE ENERGIES LIMITED BiH-1-380 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED BiH-1-380 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention95.3%Module Efficiency18.72%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED BiH-1-380?

Benchmark highlights for WAAREE ENERGIES LIMITED BiH-1-380 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 347.5 W a-Si/nc median.

Eff #13,990

18.72% Aperture Efficiency

Power density 187.2 W/m2 (1.19 percentage points below 19.91% CEC median). PTC/STC ratio: 95.3% (rank #237).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.55 V at -10 C (575.5 V string) and 58.77 V at -20 C (10 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 44.7 m2 (481 sq ft) producing 7,964 W PTC; NEC 690.8 OCPD floor is 14.02 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.28 * (1 + (-0.229/100) * (-10 - 25)) = 57.55 V | OCPD = 1.56 * 8.99 = 14.02 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED BiH-1-380: Voc=53.28 V, beta_Voc=-0.229%/C, Isc=8.99 A, STC=380.0 W, Area=2.03 m2.

Result: 10 panels max on 600 V (575.5 V); 22 panels for 8 kW (481 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED BiH-1-380?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED BiH-1-380 (a-Si/nc) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED BiH-1-380.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 362.0 W (95.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 53.28 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.99 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.94 V / 8.46 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.229 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.72% (2.03 m2) Array roof footprint density
Cell Count & Technology 72 cells (a-Si/nc) Bifacial glass-glass

How Many WAAREE ENERGIES LIMITED BiH-1-380 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED BiH-1-380 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 350 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 481 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 590 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED BiH-1-380 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED BiH-1-380 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED BiH-1-375 375.0 W 357.1 W 53.16 V 44.65 V 18.47%
WAAREE ENERGIES LIMITED BiH-1-380 380.0 W 362.0 W 53.28 V 44.94 V 18.72%
WAAREE ENERGIES LIMITED BiH-1-385 385.0 W 366.8 W 53.4 V 45.24 V 18.97%

How Many WAAREE ENERGIES LIMITED BiH-1-380 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED BiH-1-380 (57.55 V at 14 F).

Computed from Voc=53.28V and beta_Voc=-0.229%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.77 V 10 panels 587.7 V 17 panels
-10 C (14 F) 57.55 V 10 panels 575.5 V 17 panels
0 C (32 F) 56.33 V 10 panels 563.3 V 17 panels
25 C (77 F STC) 53.28 V 11 panels 586.1 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED BiH-1-380?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED BiH-1-380 in nameplate wattage and Voc, starting with Auxin Solar AXN6M612B380.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M612B380
Auxin Solar
380.0 W Tie (0 W) 47.94 V 19.3% 93.1%
CSI Solar Co Ltd CS3U-380PB-AG
CSI Solar Co Ltd
380.0 W Tie (0 W) 47.8 V 19.29% 93.5%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF
Boviet Solar Technology Co Ltd
385.0 W +5.0 W 48.45 V 19.15% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF-DG
Boviet Solar Technology Co Ltd
385.0 W +5.0 W 48.45 V 19.06% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED BiH-1-380?

Evaluate WAAREE ENERGIES LIMITED BiH-1-380 (380.0 W STC, 53.28 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED BiH-1-380 reaches 58.77 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 481 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (481 sq ft).
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED BiH-1-380 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED BiH-1-380 8 kW Residential Fit

Needs 22 modules (481 sq ft) with a 15 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Auxin Solar AXN6M612B380.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 362.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED BiH-1-380 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED BiH-1-380?

Multiplying WAAREE ENERGIES LIMITED BiH-1-380's 8.99 A short-circuit current by 1.56 equals 14.02 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can WAAREE ENERGIES LIMITED BiH-1-380 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 57.55 V cold Voc at 14 F and handles 8.99 A Isc; string inverters cap WAAREE ENERGIES LIMITED BiH-1-380 at 10 panels on 600 V.

Is WAAREE ENERGIES LIMITED BiH-1-380 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED BiH-1-380 rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.