Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED Bi-55-550 is a 550.0 W STC (508.4 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.48% efficiency, 49.91 V Voc at 25 C, and 54.71 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
550.0 W
PTC Wattage
508.4 W
Voc @ 25C
49.91 V
Efficiency
21.48%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED Bi-55-550 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED Bi-55-550: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from WAAREE ENERGIES LIMITED and peers, WAAREE ENERGIES LIMITED Bi-55-550 stands 140.0 W above the 410.0 W Mono-c-Si median and strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677). Sizing 6 kW (11 panels) to 10 kW (19 panels) yields $1,514-$2,616/yr in baseline US bill offset. Higher 49.91 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does WAAREE ENERGIES LIMITED Bi-55-550 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED Bi-55-550 (550.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED Bi-55-550 (550.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 550.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED Bi-55-550?

Dataset percentiles tracking WAAREE ENERGIES LIMITED Bi-55-550 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

WAAREE ENERGIES LIMITED Bi-55-550 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED Bi-55-550 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage550.0 WPTC/STC Retention92.4%Module Efficiency21.48%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED Bi-55-550?

Benchmark highlights for WAAREE ENERGIES LIMITED Bi-55-550 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #2,737 / 21,677

Top 13.8% STC Output

550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,517

21.48% Aperture Efficiency

Power density 214.8 W/m2 (1.57 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.71 V at -10 C (547.1 V string) and 56.09 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,250 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,626 W PTC; NEC 690.8 OCPD floor is 21.78 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.91 * (1 + (-0.275/100) * (-10 - 25)) = 54.71 V | OCPD = 1.56 * 13.96 = 21.78 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED Bi-55-550: Voc=49.91 V, beta_Voc=-0.275%/C, Isc=13.96 A, STC=550.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (547.1 V); 15 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED Bi-55-550?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED Bi-55-550 (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED Bi-55-550.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 550.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 508.4 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.91 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.96 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.03 V / 13.08 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.275 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.48% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many WAAREE ENERGIES LIMITED Bi-55-550 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED Bi-55-550 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.05 kW 303 sq ft $1,514 $2,561
8 kW Class 15 8.25 kW 413 sq ft $2,065 $3,492
10 kW Class 19 10.45 kW 524 sq ft $2,616 $4,423

How Many WAAREE ENERGIES LIMITED Bi-55-550 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED Bi-55-550 (54.71 V at 14 F).

Computed from Voc=49.91V and beta_Voc=-0.275%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.09 V 10 panels 560.9 V 17 panels
-10 C (14 F) 54.71 V 10 panels 547.1 V 18 panels
0 C (32 F) 53.34 V 11 panels 586.7 V 18 panels
25 C (77 F STC) 49.91 V 12 panels 598.9 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED Bi-55-550?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED Bi-55-550 in nameplate wattage and Voc, starting with AMPS Solar AMPS-550P-144BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AMPS Solar AMPS-550P-144BB
AMPS Solar
550.0 W Tie (0 W) 49.9 V 28.95% 94.1%
Apollo Renewables Inc Apollo-M772BH-550TW
Apollo Renewables Inc
550.0 W Tie (0 W) 49.9 V 21.48% 93.6%
Exiom Solution S A EX550-144BMH-DG
Exiom Solution S A
550.0 W Tie (0 W) 49.9 V 21.32% 93.4%
Exiom Solution S A EX550-144M-BMH
Exiom Solution S A
550.0 W Tie (0 W) 49.9 V 21.32% 93.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED Bi-55-550?

Evaluate WAAREE ENERGIES LIMITED Bi-55-550 (550.0 W STC, 49.91 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED Bi-55-550 reaches 56.09 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED Bi-55-550 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED Bi-55-550 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AMPS Solar AMPS-550P-144BB.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 508.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED Bi-55-550 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED Bi-55-550?

Multiplying WAAREE ENERGIES LIMITED Bi-55-550's 13.96 A short-circuit current by 1.56 equals 21.78 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can WAAREE ENERGIES LIMITED Bi-55-550 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.71 V cold Voc at 14 F and handles 13.96 A Isc; string inverters cap WAAREE ENERGIES LIMITED Bi-55-550 at 10 panels on 600 V.

Is WAAREE ENERGIES LIMITED Bi-55-550 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED Bi-55-550 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.