WAAREE ENERGIES LIMITED Bi-55-550 is a 550.0 W STC (508.4 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.48% efficiency, 49.91 V Voc at 25 C, and 54.71 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 550.0 W
- PTC Wattage
- 508.4 W
- Voc @ 25C
- 49.91 V
- Efficiency
- 21.48%
How Does WAAREE ENERGIES LIMITED Bi-55-550 Compare Against Peer CEC Listings?
Solar engineering breakdown for WAAREE ENERGIES LIMITED Bi-55-550: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from WAAREE ENERGIES LIMITED and peers, WAAREE ENERGIES LIMITED Bi-55-550 stands 140.0 W above the 410.0 W Mono-c-Si median and strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677). Sizing 6 kW (11 panels) to 10 kW (19 panels) yields $1,514-$2,616/yr in baseline US bill offset. Higher 49.91 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does WAAREE ENERGIES LIMITED Bi-55-550 Fall Across Listed CEC Models?
Distribution marker showing WAAREE ENERGIES LIMITED Bi-55-550 (550.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define WAAREE ENERGIES LIMITED Bi-55-550?
Dataset percentiles tracking WAAREE ENERGIES LIMITED Bi-55-550 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED Bi-55-550?
Benchmark highlights for WAAREE ENERGIES LIMITED Bi-55-550 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 13.8% STC Output
550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.48% Aperture Efficiency
Power density 214.8 W/m2 (1.57 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.71 V at -10 C (547.1 V string) and 56.09 V at -20 C (10 max).
15 Panels = 8,250 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,626 W PTC; NEC 690.8 OCPD floor is 21.78 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.91 * (1 + (-0.275/100) * (-10 - 25)) = 54.71 V | OCPD = 1.56 * 13.96 = 21.78 A
Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED Bi-55-550: Voc=49.91 V, beta_Voc=-0.275%/C, Isc=13.96 A, STC=550.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (547.1 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED Bi-55-550?
Official CEC datasheet figures for WAAREE ENERGIES LIMITED Bi-55-550 (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 508.4 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.91 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.96 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.03 V / 13.08 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.275 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.48% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many WAAREE ENERGIES LIMITED Bi-55-550 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many WAAREE ENERGIES LIMITED Bi-55-550 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.05 kW | 303 sq ft | $1,514 | $2,561 |
| 8 kW Class | 15 | 8.25 kW | 413 sq ft | $2,065 | $3,492 |
| 10 kW Class | 19 | 10.45 kW | 524 sq ft | $2,616 | $4,423 |
How Many WAAREE ENERGIES LIMITED Bi-55-550 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED Bi-55-550 (54.71 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.09 V | 10 panels | 560.9 V | 17 panels |
| -10 C (14 F) | 54.71 V | 10 panels | 547.1 V | 18 panels |
| 0 C (32 F) | 53.34 V | 11 panels | 586.7 V | 18 panels |
| 25 C (77 F STC) | 49.91 V | 12 panels | 598.9 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED Bi-55-550?
Competing CEC solar panels closest to WAAREE ENERGIES LIMITED Bi-55-550 in nameplate wattage and Voc, starting with AMPS Solar AMPS-550P-144BB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AMPS Solar AMPS-550P-144BB AMPS Solar |
550.0 W | Tie (0 W) | 49.9 V | 28.95% | 94.1% |
| Apollo Renewables Inc Apollo-M772BH-550TW Apollo Renewables Inc |
550.0 W | Tie (0 W) | 49.9 V | 21.48% | 93.6% |
| Exiom Solution S A EX550-144BMH-DG Exiom Solution S A |
550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.4% |
| Exiom Solution S A EX550-144M-BMH Exiom Solution S A |
550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.7% |
What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED Bi-55-550?
Evaluate WAAREE ENERGIES LIMITED Bi-55-550 (550.0 W STC, 49.91 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED Bi-55-550 reaches 56.09 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED Bi-55-550 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
WAAREE ENERGIES LIMITED Bi-55-550 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AMPS Solar AMPS-550P-144BB.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 508.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for WAAREE ENERGIES LIMITED Bi-55-550 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED Bi-55-550?
Multiplying WAAREE ENERGIES LIMITED Bi-55-550's 13.96 A short-circuit current by 1.56 equals 21.78 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can WAAREE ENERGIES LIMITED Bi-55-550 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.71 V cold Voc at 14 F and handles 13.96 A Isc; string inverters cap WAAREE ENERGIES LIMITED Bi-55-550 at 10 panels on 600 V.
Is WAAREE ENERGIES LIMITED Bi-55-550 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED Bi-55-550 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)